HomeMy WebLinkAboutEngineered Plans - 2015DECK
KIT./DIN. DEN
LI -T -T
HALL a
M
LIV. RM
BEDROOM
FIRST FLOOR
S
BATH Q
m
HALL
r-TWITWO1O L,
FLOOR PLAN
KNEEWALL
SECOND FLOOR
LEGEND
--98--
ROUTE 6
N
1117)
EXISTING SPOT GRADE
Old Town House
Road
CD
fi
EXISTING GAS SERVICE
—$ Ham–
OVERHEAD WIRES
IvanEn hoe Rd
TEST PIT
N LOCUS
0
3
fD p
U
O
�
�11 O
pve
p
Constonce
o m
v
0
Cardinal Ln5
6
Off-.
Bunting Ln
CD3
0
Dove Ln
3
Sheffield Rd
Mockingbird Ln
DECK
KIT./DIN. DEN
LI -T -T
HALL a
M
LIV. RM
BEDROOM
FIRST FLOOR
S
BATH Q
m
HALL
r-TWITWO1O L,
FLOOR PLAN
KNEEWALL
SECOND FLOOR
LEGEND
--98--
EXISTING CONTOUR
X MOM
EXISTING SPOT GRADE
—W
EXISTING WATER SERVICE
—G
EXISTING GAS SERVICE
—$ Ham–
OVERHEAD WIRES
TEST PIT
BENCHMARK
LOCUS MAP 98.77
NOT TO SCALE
p4cE AV
pa
99.46
Permill valid for REPAIR OF SEPTICSYSria S T —
ONLY fue to State and Local septic vau s Pave�ent
Board Wealth, review and approval is requires tir of e
dge,64 e
any, u lire additions/renovations/alterations to 99
sewag, f kcilities and/or structures/d A cilinK. _ „ �' 1 %0� _ _COQ _
99,80 S 13 43,30 I _
Yarmouth Health Deltob!1rpcnt
f 1 ate' _ a
�1
APPROVED V E ll 1�1` - ✓ _ _ x
/ 101,09:.' /
103,63 �1.38 lJ—N
X/ 10.16
\
x 13.15
Dba 'e ate c�� a5� 113.67
112,65 Y
7 5,33 105.6 `NALKW C�x 113.60
\� O 1
G 10. I
5_
107.92: ' v .�// ,r ,�/ % to
,EXISTING f f' i C)
\ 107 21PARED m/HOUSE(#35) o
c//T.O.F.=115.44
x DRI VEWA Y: --CTI
9.62 /
U01\ 107 94 / % x
\ /114.36 fn
/0 \ .108.00 _.: ..` - `.,` -7
_ �b
cx o \ 113, 6x DECK
111,6Cb
114.24 ,, 4
' - 9 EXIS71NG SEPTIC TANK
x f (NO DECK SUPPORTS SHALL
11 t 114.37 REST ON TANK)
.x-114. \ 4— -,- 't 6- , x 119,09 TOP OF TANK, EL. =112.82
x -- •: :- .,• .':.:...: INV. (OUT)=111.491-
INSTALL A 40 MILL POLY LINER "-' 'SED
S.
PROPO.
TOP OF LINER, EL.=111.00
-7-'=•--` --'
BOTTM OF LINER, EL.=108.0 BENCHMARK _ _ _ - r` '
10 �/ 45' %� 118,56 TOP OF SEPTIC TANK
VENT -1 — / EL. 112.82
117.45 + i 0 _
�l0
017,38 116.94 x i
C)x
� OT 26
`''- j 14,600 S.F.
a z ---MAP ID: 86-203 x 11963
.>
1-v ? 119.12 105.00'
118.78
x15" C.".�C i S 82 54 W
EXIS77NG LEACH PIT
(TAKEN FROM RECORD AS—BUILT)
TO BE PUMPED. FILLED WITH
SAND AND ABANDONED
MAsx PLAN REFERENCE
CERTIFIED PLOT PLAN BY LOW & WELLER, DATED JULY 18, 1984
o� PETER T. LIP_
McENTEE PROPOSED SEPTIC SYSTEM UPGRADE PLAN
CIVIL n
No. 35109 35 CONSTANCE AVENUE, WEST YARMOUTH, MA
ISZER`� Prepared for: Shane Pacheco, 81 Jasper Road, Marstons Mills, MA 02648
OWNER OF RECORD Engineering by: Surveying by: SCALE DRAWN JOB. No.
Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 217-15
ESTATE OF GARY E NEWELL 12 West
(� 35 CONSTANCE AVENUE Fo stdole,rMAf1e02644ld d E.Ware2854 hom, MSA 02538 DATE CHECKED SHEET NO.
WEST YARMOUTH, MA 02673 (508) 477-5313 (508) 273-0377 10/14/15 P.T.M. 1 of 2
NOTE: TO PREVENT BREAKOUT, THE CONTRACTOR
SHALL INSTALL A 40 MILL POLY LINER
TOP OF LINER, EL.=111.00
SEPTIC TANK BOTTM OF LINER, EL.=108.0
INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX
OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & WATERTIGHT PROPOSED S.A.S.
COVER SET TO 6" OF GRADE INSTALL INSPECTION PORT SET TO 3" OF FINISH
T.O.F.=115.4 GRADE & PLACE REBAR AGAINST CAP FOR LOCATING
F.G. EL.=99.3± F.G. EL.=114.2± F.G. EL.=115.21 F.G. EL: 115.0± CHARCOAL VENT
EXISTING
MAINTAIN 2% GRADE OVER S.A.S.
(MIN.)
REBAR
L = 18' L = 6' MAX. 10' x 45' LEACHING FIELD W/2-4"
74cVENT
®S=1% (MIN.) ® S=1% (MIN.) SCH 40 PERF_ PVC DISTRIBUTION LINES
4"SCH40 PVC 4"SCH40 PVC( -MANIFOLD
s
74" 6" EFF.
DEPTH
EXISTING 48" LIQUVEL
LEVEL I SLOPE OF PERF. PIPE = 0.5%
ADD
GAS BAFttE INV.=111.17 PROPOSED INV.=111.00 145' EFFECTIVE LENGTH
• . .,........: • . • • . ..• INV.=111.49± D -BOX
INV.=110.73 INV. EL.=110.50(END)
EXISTING
EXISTING SEPTIC TANK SOIL ABSORPTION SYSTEM (PROFILE)
ILIA
2" LAYER OF 1/8"-1/2" DOUBLE WASHED
STONE (OR APPROVED FILTER FABRIC)
NOTES: BREAKOUT ELEV.=110.73
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION. BOTTOM ELEV.=110.00
2) D -BOX SHALL BE SET LEVEL AND TRUE TO
4' MIN. OF PERVIOUS SOILS 2.5' S' 2.5'
GRADE ON A MECHANICALLY COMPACTED SIX
INCH CRUSHED STONE BASE, AS SPECIFIED 5' MIN. ABOVE ADJUSTED 10' EFFECTIVE WIDTH
IN 310 CMR 15.221(2). HIGH GROUNDWATER
SOIL ABSORPTION SYSTEM (SECTION)
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
BOTTOM OF TP, EL.=94.7 - KTP
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE _ 3/4"-1 1/2" DOUBLE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. WASHED STONE
SEPTIC SYSTEM PROFILE
N_T.S.
SOIL LOG
DATE: SEPTEMBER 3, 2015
SOIL EVALUATOR: PETER McENTEE (SE#1542)
GENERAL NOTES:
WITNESS: AMY VON HONE - HEALTH AGENT
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
TP
BOARD OF HEALTH AND THE DESIGN ENGINEER.
Elev. Depth
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
114.7 A 0"
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS_
LOAMY SAND
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
114.4 13- 10YR 4/2 4"
TO INSP ECTIOt -AND-APPROVAL-BY THE -BOARD OF HEALTH- AND -THE -
DESIGN ENGINEER.
LOAMY SAND
10YR 5/6
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
32"
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
112.0 C
ENGINEER BEFORE CONSTRUCTION CONTINUES.
PERC
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
30"/48"
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
M -C SAND
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
2.5Y 6/4
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
94.7 120"
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
PERC RATE <2 MIN/IN.(-C- HORIZON)
DIRECTED BY THE APPROVING AUTHORITIES,
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
NO GROUNDWATER OBSERVED
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
O�
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
a/,EXISTING
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
6'z HOUSE(#35)
13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
IS NOT CONSIDERED TO BE A PROPERTY LINE SURVEY.
o /T O.1- = 115.441-
1
DECK
+ N
DESIGN CRITERIA
���� �
U4 _
66'2-�
NUMBER OF BEDROOMS: 3 BEDROOMS
2`Z6
-
SOIL TEXTURAL CLASS: CLASS 1
T
DESIGN PERCOLATION RATE: <2 MIN/IN (0.74 GPD/SF)
'
P ED S.A.S�--
DAILY FLOW: 330 GPD
11- --
DESIGN FLOW: 330 GPD
r 45'
GARBAGE GRINDER: NO
EXISTING SEPTIC TANK: 1000 GALLON TANK
S.A.S.LAYOUT
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
.74 GPD/SF
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
35 CONSTANCE AVENUE, WEST YARMOUTH, MA
10' X 45' LEACHING FIELD W/2 DISTRIBUTION LINES
SIDEWALL AREA: (NOT APPLICABLE)
Prepared for: Shane Pacheco, 81 Jasper Road, Marstons Mills, MA 02648
BOTTOM AREA: 10' x 45' = 450 SF
Engineering by:
Surveying by:
SCALE
DRAWN
JOB. NO.
TOTAL AREA: .................................................. 450 SF
Engineering Works, Inc.
JC Engineering, Inc.
N.T.S.
P.T.M.
217-15
DESIGN FLOW PROVIDED: 0.74 GPD/SF(450 SF) = 333.0 GPD
12 West Crossfield Road
Forestdale, MA 02644
2854 Cranberry Hwy.
E.Wareham, MA 02538
DATE
CHECKED
SHEET N0.
(508) 477-5313
(508) 273-0377
10/14/15
P.T.M.
2 Of 2