Loading...
HomeMy WebLinkAbout14 Wisteria Road Site and Sewage Plan (2)ROUTE 28 Ii ASSESSORS MAP: 22 PARCEL: 190 �'ES� OTL.E LOGS J I LOCUS - Ci1P.RF.NT ZONING: R-25 ENGINE THOMAS McLELLAN, P.E.- Q- .E. �� I� WITNESS: DAVID FLAHERTY. R.S. II MINIMUM BUILDING SETBACKS: � - - FRONT: 30' SIDE; 15' REAR: 20' DATE. 4-28-04 PERCOLATION RATE: < 2 MIN / INCH ALLOWABLE BUILDING COVERAGE: 25 % -- TH-1 12.0 TH-2 11.5 2197 SF ! 8,800 SF = 24.9 % ELEV. ELEV. OA HORIZON 0/A HORIZON LOAMY SAND LOAMY SAND �9 2L FLOOD ZONE: B 9„ IOYR 312 1 11.2 10" IOYR 3/2 10.7 - B HORIZON B HORIZON LOCATION MAP LOAMY SAND j LOAMY SAND l0YR 5/8 IOYR 5/8 LOT 4 (8,800 SF) 33" -�_ 9.2 34" 8.7 C HORIZON C HORIZON MEDIUM SAND MEDIUM SAND 2.5Y 7/42.5Y 7/4 , 111" j 2.7 104° �.8 tJ .` OBSERVED OBSERVED 120" GROUND WATER 2.0 120" 1 GROUND WATER 1.5 T---- -T USGS GROU' D WATER ADJUSTMENT: WELL 1,411,V-29, ZONE B, ADJUSTMENT 2.1' "ZONE A ADJUSTMENT: 1.4' ADJUSTED GROUND WATER ELEVATION = 4.2 SEPTIC SYS'T'EM DESIGN BENCHMARK AT HYDRANT TAG BOLT #2004 ELEV= 12.42' 9.8 11 In Off,\ 12 40 MIT. POLY LINER 60'x 2' DEEP TOP OF LINER = 10.8 KEY: EXISTING COti POUR: - - PROPOSED CONTOUR: ...................... EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: AV UTILITY POLE: o -- FENCE LINE: - - - HYDRANT: -{}- RETAIINING WALL: DM# C14-20 •Ci, \!DXISTING { lrr \ DWELLING 10.3 FDCF OF DRIVF. 10.2 NOTES: 1. VERTICAL DATUM: ASSUMED FROM QUAD (NGVD +l-) 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM W rII AASHTO H-20 LOADING SPECIFICATIONS. 5. PIPE PITCH = 114" PER FOOT (UNLFSS NOTED OTHERWISE). 6. FIRST TOFF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DE'T'AILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 12. ALL UNSUITABLE SOIL (B HORIXON, APPROX. 34" DEEP) WITHIN 5' OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. FLOW ESTIMATE: 3 BL-DROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPI'I(' TANK: 330 _ GAL /DAY x 2 DAYS = 660 GAI. EXISTING SHED USE 1500 GAT LON SEPTIC TANK TO BE REMOVED LEACHTN+_AR A__ USI 3 FLO`7v'DIFFUSORS WITH 4' OF STONE AROUND _S.DF S AND 3.5' AT ENDS_ (31'x 12'x i' DEEP)---._-�- EXISTING GAZEBO IDz Al .A. 3 i 12'? x 2 x 1 � Rf St' (0 41 = 64 GAL/DAY ��- T01 -i: REMOVED - - 110T\i --- T0ARFA: 31' x 12' = 372 SF (0,74) =I'll GAL/DAY CAPACITY = I" WGAL/DAY (RESERVE AREA: 4 FLODIFFUSORS WITH 3' OF STONE AROUND "12 SIDES AND TAT ENDS, CAPACITY = 334 GAL/DAY) SEPTIC SYSTEM SECTION M 51' PORCH 27' 20' PROPOSED i 3BEDROOM DWELLBv`G LI, 7' IT 22' j 1 I Lr?r 13.0' GARAGE 24' PROPOSED DWELLING 2" PFASTONE 12' COVERS WITHIN 12" OF / 14.3 FINISED GRADE 3/4" - 1 112" TOP OF FOUNDATION (ONE INSPECTION COVER WASHED STONE TO BE WITHIN 6" OF GRADE) / 31' MAX. COVER VER 1 (1' MIN) ELEV.= 10.78 I1� 10.77 1 {� ELEV. I 10.71 �� e ELEV . 10.54 J 11.02 1500 GAD-BOX L ELEV. ELEV 9.28 ELEV. SEPTIC TANK E� ELEV. (6" OF STONE UNDER" 10.28 < 3 - 4 ELEV. E 31' (6" OF STONE UNDER OR USE 3 FLOWDIFFUSORS WITH 4' OF STONE MECHANICALLY COMPACTED) AROUND SIDES AND 3.5' AT ENDS TEE SIZES: AT TLTEE (31' x 12' x 1' DEEP) W INLET: 6" UP, 13" DOWN ZONE A ADJUSTED GROUND WATER ELEVATION = 4.2 OUTLET: 6" UP, 14" DOWN - i SITE AND SEWAGE PI_.AN DEMAREST - McLELLAN ENGINE: ;I";(1 24 SCHOOL STREET, P.O. BOX 46' WEST DENNIS, MA 02670 PHONE & FAX: (508) 398-7710 APPROVED BY: z' THOMAS McLELLAN, P.E. DATE: LOCATION: 14 WISTERIA ROAD I WEST YARMOUTH, MA JOHN\, Z - a DEMAPEST JR A 4 No 3sF6y� PREPARED FOR °l, OMAN CONSTRUCTION ass u SCALE: 1" = 20' DATE: 6-10-04 REFERENCE' LAND COURT CASE 11435 Z. I REVISED: 8-30-04 (ADJUST ELEVATIOI