HomeMy WebLinkAbout112.46 - Title 5 Site PlanSYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED X s9 EXIST. SPOT ELEV.. 9s PROPOSED CONTOUR DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 110 GPD U 198-4] PROPOSED. SPOT EL USE A 330 GPD DESIGN FLOW - THI SEPTIC TANK: 330 GPD (2)= 660 �} TEST HOLE - Y USE A 1500 GAL. H-10 SEPTIC TANK 2> SLOPE OF GROUND USE A 1000 GAL. H-10 PUMP CHAMBER UTILITY POLE y4 FIRE HYDRANT LEACHING: NOTE: NOT ALLSrMBOLs wr APPEAR w DRAWNc (9) CULTEC C4 UNITS IN FIELD CONFIGURATION OF 3 ROWS OF 3 UNITS, FOR TOTAL OF 72 LINEAL FEET. 72 L.F. x 6.7 SF/LF = 482.4 SF x 0.74 = 356.9 GPD. *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM MA APPROVED DATE BOARD OF HEALTH NOTE: INVERT INTO EXIST. CESSPOOL ELEVATION 44.9' BUOYANCY CALCS: 1000 GAL. H-10 SEPTIC TANK WGT: 8240 LBSf 3,35.09 3.2 x 8.5 x 4.83 x 62.4 - 8197 LBS DOWN (OK) 1500 GAL. H-10 ST WGL•11480 LBS. / 2.8 x 10.5 x 5.67 x 62.4 - 10,401 LBS DOWN (OK) // Q / 33 735.49 �. 10-.005 n SYSTEM PROFILE MARKED WITH MAGN€TICTTAPSHALL E OR ®E NOTES ES PROVIDE WATERTIGHT MIN, 20" DIAM. (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. - ACCESS COVERS TO W1T}RN 6" OF FIN. GRADE - - 1. DATUM IS APPROX. NGVD TOP FOUND, EL. 49.25' - - 2. MUNICIPAL WATER IS EXISTING \ 1 46.0' PROVIDE INSPECTION PORTS TO MINIMUM .75' OFC R OVER PRECAST 48 - 48.5 3. MINIMUM PIPE PITCH 2E SLOPE REQUIRED OVER SYSTEM WITHIN 3" OF FINISH GRADE � TO BE 1/8' PER FOOT. PRECAST H-10 PROP. TEE 4. DESGN LOADING FOR ALL PROPOSED PRECAST UNITS R2I0 (T+�•) 4"RSCH40 PVC TO BE AASHO H -LQ -- - PIPES LEVEL 1ST 2' - CULTEC #410 GEOSYNTHETIC a Z" FILTER FABRIC COVER 5. PIPE JOINTS TO BE MADE WATERTIGHT. ` OVER UNITS * O" 1300 GAL H-10 14' �_� 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 44.0 TEESEPTIC TAW TEE 43.75' -- a7.0' 310 ,&R 15.000 (TITLE 5.) 4' U0. LEVEL - i oms��e�a�eajei ACME OR EQUAL GAS BAFFLE �[ / em!i!i!i?:!CC:.•i! 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO TUF-TITS EF -4 46.55'BE USED WATERPROOF/WATERTIGHT EFFLU€NT FILTER w .46.75' / 46-5 025, PURPOSE. LOT LINE STAKING OR ANY OTHER EOU 0 0 0 0 0 0 0 0 0 0 o c 8. PIPE FOR SEPTIC SYSTEM TO SCH, 40-4' PVC. 0 0 0 0 0 0 0 0 0 0 0 0 j, 46.3' 0 0 0 0 0 0 0 0 0 0 o c o„o„o„o„o„o„O„oo„o„o, WATER TEST D'SOX FOR LEVELNESS CULTEC C4 UNITS (9 TOTAL) 9. COMIONENTS NOT TO BE BACKFILLED OR CONCEALED 1L __ 6" 'CRUSHED STONE OR M€CWWICAL OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 24' X 12' WITHOUT INSPECTION BY BOARD OF HEALTH AND COMPACTION. (15.221 [2]) PERUIS;ION OBTAINED FROM BOARD OF HEALTH. (NO STONE PROPOSED) - 10. COMTRACTOR SHALL BE RESPONSIBLE FOR CALLING PROVIDE SPLASH PADS 4.0' DIGSAF[ ( 1 ) AND VERIFYING THE MIN. BELOW PIPING LOCATIONOFALL& OVERHEAD UTILITIES (2-X SLOPE) ( x SLOPE) - (-!-X SLOPE) PRIOR '0 COMMENCEMENT OF WORK. 11. O'N UNSUITABLE MATERIAL ENCOUNTERED SHALL BE USE (PERCHED) G -W AT EL A2. �_, 5' REMOVLJ 5' BENEATH AND AROUND THE PROPOSED 46' C i0X 5' FOUNDATION 11' SEPTIC TANK PUMP LEACHING LEACHING FACILITY. CHAMBER FACILITY 12. E:XCTING LEACHING FACILITY SHALL BE PUMPED AND REMOVE) OR PUMPED AND FILLED HATH CLEAN SAND. 13. INS-ALLER TO DETERMINE IF ELECTRICAL SYSTEM ADEQUATE FOR PROPOSED PUMP INSTALLATION (MUST BE UPGRADED IF NOT ADEQUATE), 14. ELEiTRICAL PERMIT REQUIRED FOR PUMP INSTALLATION ALARM AND CONTROL PANEL PR>V1DE QUICK DISCONNECT r x „ 5 TO K INSTALLED INSIDE - ,1 1UILDING- ALARM TO BE ON IN 3C DISCHARGE LINE �� � SEPARATE CIRCUIT FROM PUMP ���'''!!! _ I IN 4 i - 1000 GALL+ S If SL PTRE LINE500 TEST HOLE LOGS FLOAT SWITCH ALARM ON RESERVE+ SLOPEE To O DRAIN BACK TO PC SETTINGS: PUMP ON CHECK VALVE HOLE VE j 2 4" WORKING RANGE 5 M'.ERS SRM 4 ENGINEER: ARNE H. OJALA, PE, SE oO� I 4" SSUBAERSIBLEYSTEM (OR E4/10 HP PUMP AMY VON HONE, RS PUMP OFF 12 WITNESS: DATE: 1/28/10 PUMP CHAMBER PERC. RATE _ < 2 MIN/INCH (SIEVE) i 1 (NOT TO SCALE) I WATERPROOF/WATERTIGHT CLASS SOILS I NOT TO SCALE ASSESSORS MAP 112 PARCEL 46 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE: 15.405 1h: REDUCTION IN SEPARATION TO (PERCHED) G -W (5' TO 4') /A6' / 24,5 0 SFt 1xa� 3' CAUTION: OVERHEAD WIRES IN AREA OF PROPOSED EXCAVATION WORK -C]i raE y5 + BALD i EE 5S CC 49 I BENCHMARK 6 DXWELUNG CELLAR 3Ci CDR BRICK PATIO r ELEV. - 49.0' se TOP FNDN. - ELEV. = 49.25' Gn r x\49 25 �- c - \ CRA YIL 1`1\�`�ru'-,�.5=' / k PROP. VENT WITH CHARCOAL FILTER AND DUGSCREEN (FINAL PLACtMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) \ \, CRAWL. 6 - 5' REMOVAL OF UNSUITABLE SOIL REWIRED AROUND PERNIETER OF LEACHING FACILITY, t � DOW4' TO SUITABLE SOIL LAYER. REPLACE WTH CLEAN MED. SAND, TO MEET `v _ ! SPECIFICATIONS OF 310 CMR 15.255(3) 1 @ H G PROODE APPROX. 75' OF 40 MIL LINER AT 5' OFF SAS may% ,� O IN AREA SHOWN. TOP AT ELEV. 46, BOTTOM AT EL. 42'1 A V 1 4- -4 _ q 4 br CESSP>Sell� NOTE: RECENT WATERLINE INSTALLED IN PLACE OF BROKEN LINE; CONFIRM LOCATION AND SLEEVE SEWER LINE )S$4 t '" FOR 10' EITHER SIDE OF CROSSING. A - (FAILED) PROVIDE MMI. 10' BETWEEN PROPOSED SAS AND WATERLINE i i W -�a Q �' pK .F I NOTE: SEPTI; SYSTEM IS NOT DESIGNED FOR VEHICLE I Q 3 LOADWG 83 0 Ills \ _� I C44 * = PROPOSED SAS (9) CULTEC C4 UNITS (NO STONE) SCALE: 1" = 20' 4 ELEV. ELEV. 0" (FAILED) 44.2' 0" 4 47 3' 14" 30" .,L.1 f.,r Hl P.111 UI 51.1'Ill 51 �IHAl 60" ,lu. lu Jlal 1 I ... if scPUc .anellc, S. ..I Il. altli n u .,I appn.�:J 1, I.yuu ul I I lulu,. aJ.l ilk .uu.a lulual .call..... lu 1 .0 un.0 th IL. 111 Depai lmr 1.1 tv/eAITI VED 1 2" D A SL B SL C1 PERCHED H2O Si LOAM SL iulrc 3/Z 12" B LS 1OYR 5/6 30" 44.8' SIEVE C 39.2' 60" PERCHED H2O 42.3' LS 2.5Y 5/4 28.2' 120" 37.3' ----- --- AIS .- --- o� DANIE ' z u.-t.ml o A. U 0.1ALs- :n II Na, 4i)5t � h5: F / f6/1 0 DATE DANIEL A, OJALA, P.E., P.L.S. TITLE 5 SITEtro-o"LAN OF 23 WILLOW STREET YARMOUTH PORT PREPARED FOR CAPEWIDE ENTERPRISES FEBRUARY 1, 2010 REV. 5/30/10 (MOVE SAS) REV. 6/7/10 (BOH COMMENTS) Scale: 1 "= 20' 0 10 20 30 40. 50 TE_I off 508-362-4541 fax 508-362-9880 downcope.com down cape engineering, Inc, civil engineers Ion surveyors 939 Main Street ( Rte &A) YARMOUT-IPORT MA 02575 10-005.DWG(SBO)