34.3 - Framing Plans
17 swuh� I FIRST FLOOR PLAN /411 _ 1 1.011 GENERAL STRUCTURAL NOTES: 1. ALL NEW CONSTRUCTION IS TO BE IN ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING CODE FOR ONE- AND TWO- FAMILY DWELLINGS, 8TH EDITION (780 CMR), AND ALL AMENDMENTS, WHICH IS BASED ON THE 2009 INTERNATIONAL RESIDENTIAL CODE. 2. THE SCOPE OF THIS PROJECT IS TO RAISE THE EXISTING CEILING HEIGHT IN THE LIVING ROOM. 3. THE DESIGN DOES NOT INCLUDE PROVISIONS FOR RETROFIT OF THE EXISTING STRUCTURE TO MEET 110 MPH, EXPOSURE 'C'WIND DESIGN REQUIREMENTS. BADERA ENGINEERING, L.L.C. SHALL NOT BE HELD LIABLE FOR THE EXISTING CONSTRUCTION THAT REMAINS UNDISTURBED AS PART OF THE RENOVATION OF THE EXISTING STRUCTURE. IF THE SCOPE OF THE PROJECT IS REVISED FOR ANY REASON FROM WHAT IS OUTLINED ON THESE PLANS, THE DESIGN AS SHOWN HEREON SHALL BE DEEMED NULL AND VOID. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL APPROVALS AND PERMITS PRIOR TO CONSTRUCTION. 5. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE LOCAL BUILDING OFFICIAL FOR ALL REQUIRED STRUCTURAL INSPECTION(S). IF THE BUILDING OFFICIAL REQUIRES THAT THE INSPECTION(S) BE COMPLETED BY THE ENGINEER OF RECORD, THE CONTRACTOR SHALL CONTACT THE ENGINEER OF RECORD 24 HOURS PRIOR TO THE TIME WHEN THE INSPECTION(S) IS TO BE PERFORMED. THE CONTRACTOR SHALL INSURE THAT ALL STRUCTURAL MEMBERS AND CONNECTIONS ARE VISIBLE FOR INSPECTION. IF DURING THE INSPECTION, ANY PORTION OF THE STRUCTURE IS DEEMED NOT VISIBLE OR IS INACCESSIBLE FOR INSPECTION, FINAL APPROVAL OF THE ENTIRE STRUCTURE WILL NOT BE GIVEN UNTIL THIS CONDITION IS CORRECTED AT THE CONTRACTOR'S EXPENSE. 6. ALL WOOD CONSTRUCTION CONNECTORS AS SPECIFIED ON THESE CONSTRUCTION DOCUMENTS TO BE SIMPSON STRONG -TIE IN ACCORDANCE WITH CATALOG C-2011. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL ALL CONNECTORS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 7. ALL ENGINEERED LUMBER PRODUCTS TO BE TRUS JOIST OR APPROVED EQUAL INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 8. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES AND ACCEPTED STANDARDS. 9. ALL EXISTING CONSTRUCTION REQUIRING MODIFICATION FOR THE INSTALLATION OF THE NEW STRUCTURAL COMPONENTS SHALL BE CUT AND PATCHED TO MATCH EXISTING CONSTRUCTION. 10. PROVIDE TEMPORARY CONSTRUCTION AND OR SHORING AS REQUIRED TO SUPPORT EXISTING ROOF AND EXISTING LIVING ROOM CEILING DURING CONSTRUCTION OF NEW RAISED CEILING. 'd 1R n TIF X 2J Z 3K B.F. 2K B.F. I iJ 2K B.F. NEW (2) 13/4" x 117/8" LVL RIDGE BEAM (2) 2 X6 HEADER ABOVE GABLE VENT WITH 1J/2K. LIVING SISTER BALLOON FRAMED STUDS TO EXISTING GABLE END WALL STUDS. (SEE NOTE 1) I I i- -- - - - - - - - - - - - - - - - - - - - - - E w W F- U Of LL LUg0 LL to m x� CV Q WZw �FW co -- N C/) M ROOF FRAMING PLAN Y2 11 = 1 11_01 1 NEW 24"x 24" x 12" THK. CONCRETE FOOTING WITH (3) No. 5 REBAR EACH WAY, UNDER EXIST. LALLY COLUMN. 5� Q FOUNDATION PLAN Y2 It = 1 1_011 'NOTES: 1. EXISTING PLATFORM FRAMED FIRST FLOOR GABLE END WALL TO BE SISTERED WITH BALLOON FRAMED STUDS AT 16" O.C. AND NEW BALLOON FRAMED KING STUDS TO BE ADDED AS SPECIFIED. RECEIVED APR o 6 2012 BUILDING DEPARTMENT By _ LEGEND: 0>—— GRIDLINE NUMBER I DETAIL D001 TOP # = DETAIL NUMBER BOTTOM # = DRAWING SHEET NUMBER 1 SECTION SI00 TOP#=SECTION NUMBER BOTTOM # = DRAWING SHEET NUMBER j WALLTYPE 6 EXTERIOR WALL SHEATHING NAILING REQUIREMENTS V121 IN ACCORDANCE WITH'MASSACHUSETTS CHECKLIST", MORE SPECIFICALLY'NOTE 4-.(780 CMR 5301.2.1.1) - TOP # = EDGE NAILING SPACING BOTTOM # = FIELD NAILING SPACING s/- DIAMETER A307 STEEL ANCHOR BOLTS WITH 3'x 3"x 1/4' PLATE WASHERS WITH 7' MINIMUM EMBEDMENT INTO CONCRETE. ® BEARING WALL ROOF OVERFRAME HI HEADER OR BEAM SIZE J JACK STUD K KINGSTUD K B.F. KING STUD (BALLOON FRAMED) BW BASEMENT WINDOW OWINDOW OR DOOR TYPE PERMIT SET BADERA ENGINEERING, L.L.C. RESIDENTIAL STRUCTURAL CIVIL SITE DESIGN P.O. BOX 716 ORLEANS, MA 02653 PH: (508}776-6804 email: jasbaCera@gmail.mm THESE PROJECT DRAWINGS, INCLUDING THE NOTES AND DETAILS, ARE THE SOLE PROPERTY OF BADERA ENGINEERING, L.L.C. ANY USE WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. © COPYRIGHT - BADERA ENGINEERING, L.L.C. DRAWING SHEET NAME: LIVING ROOM CEILING RENOVATION FRAMING PLANS PROJECT No. SHEET NO. DATEt s"100 DATE: 03/19/2012 SCALE: Y4t 11-01 1 OF: 2 J.v JAMES A. yGN ,a ADERA, JR. CIVIL N No. 41715 ,n GISTV FSS/ONAL EAG\ 2012 D cQ G Z O Q W W U � Q z o z U ® V J W ti ® C� W o, Q < W >J cy) No. REVISION/ISSUE DATE THESE PROJECT DRAWINGS, INCLUDING THE NOTES AND DETAILS, ARE THE SOLE PROPERTY OF BADERA ENGINEERING, L.L.C. ANY USE WITHOUT PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. © COPYRIGHT - BADERA ENGINEERING, L.L.C. DRAWING SHEET NAME: LIVING ROOM CEILING RENOVATION FRAMING PLANS PROJECT No. SHEET NO. DATEt s"100 DATE: 03/19/2012 SCALE: Y4t 11-01 1 OF: 2