Loading...
HomeMy WebLinkAboutReview Checklist � 1��/6�-/� TOWN OF YARMOUTH a � SEWAGE PLAN REVIEW CHECKLIST . Location: A.M. � Lot �� Zone of Contribution: In Out � Acreage Commercial: Residential: ,� Street: (�j/ Village: Floor Plan: #Bedrooms: 3 Owner: ��,�1�- Installer: � Address: Phone: ' Phone: � � � � c� __ � 1�' Builder: Engineer: Address: Phone: �- -- �j Phone: � ���� � / , �� � ` � � �s ' .C>��`�� N/ S O 1.R ired#of co ies received 2.Date of soils e�m and ercolation test not older than 2 years �� 3.4-5 ft of na.tura occurrin ervious material, above water table ��' 4.Foundation 2 ft above hi int of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Var.: L/ 6.Benchmark indica.ted and shown-NGVD if near wetlands . 7. S tic tanlc minimum 10 ft from foundation,deck Var.: 8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �/ 9.Leachin minimum 100 ft from wetlands Var.: . 10.Leachin minimum 150 ft from drinicing welU25 ft irri tion well Var.: 1 l.Tank/leachin minimum 10 ft from ro line Var.: 12. S stem meets all other setback r uirements Var.: �/ 13.Uses ad' stment for maximum high groundwater V .: `--s 14.Leachin set 4-5 ft above adj.water or bottom est ho Var.: , T5. S stem not in to or subsoil A,B horizons) 5'remov 16.Pro osed contours are suita.ble 17. S stem meets slo e r irements-min. 1/8", '/a" eferred 18. System meets breakout r uirements PVC liner: Wall: ; 19. S ified tee sizes are ro er, as baffle on outlet tee ' 20. Sewa e is under 10,000 d for arcel ��. i 2 i.No ba e dis osal ' 22. S stem ad uatel sized for its intended use 23.Mmimum 6"stone or com acted below tanlc and dbox . 24.Manhole covers within 6"of ade, ump chamber cover to grade � 25.Ins ection ort on lastic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes 27.P stem-2" line,w hole,check valve,tee in dbo� um size �--- 28. S tic tank/ um chamber to be factory wa roofed `�- 29.Vent rovided if leachin below 3 feet,under driveway/ arkin �„ 30.Buoyancy calcula.tions for tank/ um chamber ' 31.En ' eer to ins ect and cert' soils: wall: commerciaL• 32.E ' eer/Re ' tered Sanitarian and Land Surv or sta;n s/si ture � ' 33.H-201oading is subject to vehicular traffic, oundwater � 34.Title V A lication and ermit fee, installer si ture ' 35.Foundation footin min. 2 feet above ad'usted ound water for new house 36.Deed Restriction r uired max. #bedrooms: max. flow: d ' 3T.Check area lots for oundwater/Label aundwater in Assessor's M i i Plan reviewed by: _ � 6l03/03 � . f