Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2008LEGEND LOT SIZE 40,000 S.F. MIN. PROPOSED SPOT ELEVATION 10OX0 EXISTING SPOT ELEVATION ----68 PROPOSED CONTOUR 68 EXISTING CONTOUR MIN. -w- PROPOSED WATER SERVICE -G-PROPOSED 35' NATURAL GAS SERVICE CATV -PROPOSED CABLE SERVICE T&E PROPOSED TELEPHONE AND ELECTRIC SERVICE @ PROPOSED AREA DRAIN PROPOSED BACKWASH PIT USE (�) H-20 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) PROPOSED LAMP BENCHMARK: HYDRANT* TAG BOLT 1008 EL=70.76' VARIANCES TOWN OF YARMOUTH HEALTH REGULATION 3.7 - FOUNDATIONS OF DWELLINGS SHALL NOT BE LESS THAN TWO FEET ABOVE THE HIGHEST POINT IN THE ROAD: FROM 2' AE30VE TO 2.04' BELOW (4.04') ftK 0 x X Z, H-1 9, +1 + + 7 + + + + ILA') 0 // - I . vim Al GH POINT IN ROAD tl -"-\I + +1 SWALE, + .,70.04' THINNED TREES + + 1B K LO REA + + k .0 s + 0/ G v1sr W G + + .0. 1-1 G- + 1.1 - I., ALL GATES TO OPEN OUTWARD AND BE SELF-CLOSING WITH LATCH ON INSIDE. SOLID WOOD FENCE AS PER BUILDING CODE. DOORS TO BE ALARMED. 01 *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM TOP FNDN. AT EL. 68.0' SYSTEM PROFILE ACCESS COVERS TO WITHIN 6m OF FIN. GRADE (NOT TO SCALE) ACCESS COVER TO WITHIN 3m OF FIN. GRADE ACCESS COVER (WATERTIGHT) TO WITHIN 6m OF FIN. GRADE MINIMUM .75- OF COVER OVER PRECAST F66.5 2X SLOPE REQUIRED OVER SYSTEM 65.0'± RUN PIPE LEVEL 2" DOUBLE WASHED PE4STONE *62.58 ;rnp npczr ol OR GEOTEXTILE FABRIC PROPOSED 1500 GALLON SEPTIC 62.16' TANK (H- 20 \5-1 -.9v 6" SUMP n GAS CXD 61.19' BAFFLE 61.36 0 r-1 17-1 0 .-61.0' r-1 r-1 r-1 [= = DEPTH OF FLOW 4' H-10 SEPTIC TANK \__6- CRUSHED STONE OR MECHtICAL 0 0 0 r-1 TEE SIZES: . COMPACTION. (15.221 [2]) 2# E-1 17-1 1771 0 M M 0 INLET DEPTH H-20 DBOX 3/4" TO 1 1/2" DOUBLE WASHED STONE OUTLET DEPTH 14" (4) H-20 500 GALLON CHAMBERS X SLOPE) SLOPE) (-I-% SLOPE) FOUNDATION- 13' SEPTIC TANK 55' D' BOX 21' LEACHING FACILITY DICE #07-049 CATV R\ISE-R",J/ 'TEL RISER:,I LJ1 ZONING SUMMARY ZONING DISTRICT. R-40 DISTRICT MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' i SHAPE FACTOR 22 MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20' MIN. REAR SETBACK 20' MAX. BUILDING HEIGHT. 35' MAX. BUILDING COVERAGE NOTTO EXCEED 25% LS PROPOSED: 9.7% BOTTOM 42 x 12.83 (.7!q_ 398 GPD 14" PROVIDE VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT \MTH HOMEOWNER CONSULTATION) ON 01 (80 S.F.)' UNDISTL (SEEVENT NOTE ON PLAN) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNEnC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 59.0' BOTTOM TH-2 EL. 52.7' -67- BENCHMARK: NAIL IN TREE EL=68.0' - -e4- - �0 CN NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR PROPOSED PRECAST DBOX & LEACH CHAMBERS TO BE AASHO H-20, SEPTIC TANK TO BE H-20. 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO � BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRA CTORISHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. COORDINATE ALL U11LITY INSTALLAT10N WITH PERMITTING AUTHORITIES. AND APPROPRIATE VENDORS. LOCUS MAP SCALE: 1" = 2,000'± ASSESSORS MAP 112 PARCEL 48 LOCUS IS NOT WITHIN APD (ZONE 11) TEST HOLE LOGS ENGINEER: A. H. OJALA, PE WITNESS: PHIL RENAUD, YBOH DATE: MARCH 29, 2007 PERC. RATE < 2 MIN/INCH CLASS I SOILS P# - off 1:T1 ELEV. 1::P SYSTEM DESIGN: 63.5' o,, GARBAGE DISPOSER IS NOT ALLOWED O/A DESIGN FLOW. 5 BEDROOMS 0 110 GPD 550 GPD 1 OYR 3/3 USE A 550 GPD DESIGN FLOW E SEPTIC TANK: 550 GPD (2) = 1100 FS 1 OYR 7/1 USE A 1500 GAL. SEPTIC TANK 401 4's B LEACHING: SIDES: 2 (42 + 12.83) 2 (.74) 162 GPD LS BOTTOM 42 x 12.83 (.7!q_ 398 GPD 14" 1 OYR �4/4 62.3' 14" TOTAL: 756 S.F. 560 GPD USE (�) H-20 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) C WI TH 4 STONE ALL AROUND PERC MICS MA of APPROVED DATE BOARD OF HEALTH 120 1 OYR 6/6 of 53.51 120 O/A 1 OYR 3/3 E FS 1 OYR 7/1 B LS 1 OYR 4/4 C mcs 1 OYR 6/6 NO GROUNDWATER ENCOUNTERED ELEV. 62.7' 31.5' 52.7' rj`II! I �11�0 TV. - 111 -,3 A�URVt ss - T' r tA��6 kA DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR PETER TROUTMAN DATE: JAN UARY 23, 2008 REV. DATE: JANUARY 28, 2008 (SHED, D.W.) REV. DATE: MARCH 14, 2008 (MOVE HOUSE, SEPTIC) REV. DATE: MARCH 18, 2008 (MOVE HOUSE) Scale: 1 "= 20' 7777776 10 20 30 40 50 FEET Is 0 W IE rp) MAR 2 6 2008 off 508-362-4541 fax 508 362-9880 HEALTH DEPT. -I down ccpe engineering, inc. Cl VIZ- ENGINEEWS L AND SUR VE- YORS 9J9 Main Street YARMOUTHPORT, IWASS. .07-049 TROUTMAN.DWG (DDF)