Loading...
HomeMy WebLinkAboutReview Checklist1 1- ,6- i� TOWN OF YARMOUTH ' : SEWAGE PLAN REV�W CFIECKLIST Location: A.M. �L � Lot� Zone af Contribution: In Out �l Acrea.ge ` ' ,, �� Commercial: Residential: C,� Street: �� ��^���,�u� i� � Village: Floor Plan: Cj #Bedrooms: 2-- Owner: Insta.11er: Address: Phone: - � Phone: Builder: Engineer: L s Address: Phone: Phone: _ ��✓'� 7 / „_�,-1 7 �.2 C �� N/A YES NO 1.Required#of co ies received 2.Date of soils exam and percolation test not older than 2 years � 3.4-5 ft of natura.11 occurrin ervious materia.l, above water table � 4.Founda.tion 2 ft above hi oint of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Vax.: 6.Benchmark indicated and shown-NGVD if near wetlands �/ 7. S tic tank minimum 10 ft from founda.tion, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leachin minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking welU25 ft nrigation well Var.: 11.Tank/leachin minimum 10 ft from ro erry line Var.: 12. S stem meets all other setback r irements Var.: 13.Uses adjustment for maximum hi oundwater Var.: 14.Leachin set 4-5 ft above ad'.water or bottom of test hole Var.: 15. System not in to or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable �� 17. S stem meets slo e r uirements-min. 1/8", '/4" referred 18. System meets breakout r uirements PVC liner: Wall: �� 19. Specified tee sizes are roper, as baffle on outlet tee 20. Sewage is under 10,000 gpd for arcel ,L� � = 21.No arbage disposal 22. S stem ad ua.tel sized for its intended use 23.Minimum 6"stone or com acted below tank and dbox • 24.Manhole covers within 6"of grade, um cha.mber cover to grade �� 25.Inspection ort on pla.stic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pump system-2" line,wee hole,check valve,tee in dbo� um size - 28. S tic tank/p chamber to be factory wat roofed 29.Vent provided if leaching below 3 feet, under driveway/ arkin , 30.Buoyancy calcula.tions for tank/ ump chamber ; 31.En ' eer to ins ect and c ' soils: wall: commerciaL• i 32.Engineer/Re 'stered Sanitarian and Land Surveyor sta.m s/signature � 33.H-20 loadin is subject to vehicular traffic, groundwater ,,,_� 34.Title V A lication and ermit fee, installer si ture i 35.Founda.tion footing min. 2 feet above adjusted ground water for new house f 36.Deed Restriction r ired ma�r. #bedrooms: max. flow: d �- 37.Check area lots for oundwater/Label oundwater in Assessor's Map .�-�" Plan reviewed by:_ (�� c�o3io3 � �