Loading...
HomeMy WebLinkAboutReview Checklist �- zZ- � s' . TOWN OF YARMOUTH ' SEWAGE PLAN REVIEW CHECKLIST � p� � Location: A.M. tj`�S Lot� Zone of Contribution: In Out� Acreage �� Commercial: Residential: � Street: Village: . Floor Plan: � #Bedrooms: � Owner: ��.uJ3f7//,/�/� s ¢��P Installer: Address:�-^' Phone: -' z, ' Phone: Builder: Engineer: / Address: Phone: � 7 7�-- 7 Phone: - /l��"'��-/, ���c-��'� N/A YES NO l.Required#of co ies received 2.Date of soils exam and colation test not older than 2 ears 3.4-5 ft of natural occurrin ervious material, above water ta.ble �-�� 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Vaz.: `.-� 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from founda.tion, deck Var.: 8. Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leachin minimum 100 ft from wetlands Var.: • 10.Leaching minimum 150 ft from drinkin welll25 ft irri ation well Var.: 1 l.Tank/leaching minimum 10 ft from property line Var.: ✓ 12. S stem meets all other setback r uirements Var.: 13.Uses adjustment for maximum high groundwater Var.: � 14.Leachin set 45 ft above ad'.water or bottom of test hole Var.: I 15. S stem not iri to or subsoil(A,B horizons)or 5'removal 16.Pro osed contours are suitable 17. S stem meets slo e r uirements-min. 1/8", '/4" referred 18. S stem meets breakout r uirements PVC liner: Wall: �� . 19. S ecified tee sizes are ro er, as baffle on outlet tee �� 20. Sewa e is under 10,Q00 d for arcel . 21.No garbage dis osal �� 22. S stem ad ua.tel sized for its intended use �,� i 23.Mmimum 6"stone or com acted below tank and dbox ; � ° 24.Manhole covers within 6"of ade, um chamber cover to ade �--� 25.Ins ion ort on lastic chambers/leach field �� 26.Electrical ermit for um ehamber/S arate meter for du lexes • 27.Pum s stem-2"line,wee hole,check valve,tee in dbo� um size 28. S tic tank/ um chamber to be factory waterproofed � 29.Vent rovided if leachin below 3 feet,under driveway/parkin 30. Buoyanc calculations for tank/ ump chamber /' ' 31.En ' eer to ins ect and cert' soils: wall: commercial: .�� 32.En ' eer/Re ' tered Sanitarian and Land Surv or stam s/si ture ��� 33.H-201oading is subject to vehicular traffic, oundwater 34.Title V A lication and ermit fee, insta.11er si ture �� � 35.Founda.tion footin min. 2 feet above adjusted ound water for new house -� 36.Deed Restriction r uired max. #bedrooms: max. flow: d I�I 37.Check area lots for oundwater/Label oundwater in Assessor's Ma Plan reviewed by: /� wo3�o3