Loading...
HomeMy WebLinkAbout134.3.3 - ElevationsASPHALT ROOF SHINGLES RED CEDAR _� x CLAPBOARD Q 4• T.W. � m r� FRONT ELE"!=TION CONTINUOUS FUDGE VENT LEFT ELEVATION 1,P/,1'L� RECEIVED, FEB 24 2n;5 OWN CLERK r YARMOUTH, MA JAN2015 YRRIMOUTH k's -ROVED 12 FEB 2 3 2015 YARMOUTH GENERAL NOTES: 1. USE "TYVEK' OR EQUIVALENT ON ROOF AND SIDEWALLS. 2. BASEMENT UTILITY WINDOWS TO PROVIDE GLAZING TO MEET STATE REGULATIONS. 3. GUTTERS AND DOWNSPOUTS TO BE PROVIDED WHERE REQUIRED. 4. PROVIDE FLASHING ABOVE ALL WINDOWS AND DOORS. 5. DOUBLE JOISTS BELOW ALL PARTITION WALLS. 6. VENT ATTIC SPACE TO MEET STATE CODE REQUIREMENTS. 7. ALL CONCRETE TO BE A MINIMUM OF 2500 PSI STRENGTH AT 30 DAYS. 8. OWNER AND CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR CONSTRUCTION AND CONFORMANCE WITH ALL STATE AND LOCAL RULES AND REGULATIONS. INSULATION NOTE: FLOORS ABOVE UNHEATED AND BELOW HEATED SPACE - 9" R-30 FIBERGLASS INSULATION OR BETTER. FLAT CEILINGS ABOVE HEATED AND BELOW UNHEATED SPACE -12" R38 FIBERGLASS INSULATION OR BETTER. EXTERIOR WALLS ABUTTING HEATED SPACE - 5.5"R-21 FIBERGLASS INSULATION OR BETTER. nee LMis DATE: GRE INN DESIGN SCALE: 131 QUAKER k1EETINGHOUSE ROAD, EAST SANDWICH, MA 02537 www.greywing.com (508) 888-0886 ELEVATIONS JAN 23 2014 PROJECT : LOT 3 WALDEN WAY, YARMOI 3 BEDROOM 2 112 BATH CAPE 114" = V-0" Oub6ncompanies.com 508 430-4700 C 2014 GreyMna Design W8 RK-08ee SHEET: nn.eroa.wa,Wawmv,.Bnwi.MPa+"rdm., PROJECT N0: G140101