HomeMy WebLinkAbout143.112 - Sewage Design PlanSOIL TEST PIT DATA:
TEST PIT #1- TEST PIT #2
GRD. EL. 82.8 GRD. EL. 84.4
EST. HIGH GW. NA EST. HIGH GW. NA
FILL
EL = 75.3
LO110YRY 7/3 D
90"
156"
FILL
EL = 73.4
CO 0R R 7�3D
SEPTEMBER 29, 2005
TEST PIT #3
GRD. EL. 85.3
EST. HIGH GW. NA
132"
180"
DATE:
DATE:
9/29/05
9/29/05
TEST BY:
TEST BY:
THE BSC GROUP, INC.
THE BSC GROUP, INC.
WITNESSED BY:
WITNESSED BY:
AMY VON HONE
AMY VON HONE
PERC. RATE:
PERC. RATE:
N A MIN./INCH
N/A MIN./INCH
SOIL EVALUATOR
SOIL EVALUATOR
MARK DIBB
MARK DIBB
SOIL CLASS:
SOIL CLASS:
1
1
L.T.A.R.
L.T.A.R.
0.74 G.P.D./SQ.FT.
0.74 G.P.D_/SQ.FT.
TEST PIT #4
TEST PIT -#
GRD. EL_ 84.6
GRD. EL. 82.5
NO WATER TO 62
EST. HIGH GW. NA
EST. HIGH GW.
16"
FILL
EL = 69.6
COAR
D
7/3
3�.Lo f
180"
186"
DATE:
9/29/05
TEST BY:
THE BSC GROUP, INC.
WITNESSED BY:
AMY VON HONE
PERC. RATE:
N A MIN./INCH
SOIL EVALUATOR
MARK DIBB
FILL
EL = 82.6
A
LOAMY SAND
10YR 3/2 52"
LOAMY SAND
10YR 5/6
MEDIUMI SAND
10YR 7/3
162"
168"
192"
EL = 62.0 246'
DATE:
10/13/05
TEST BY:
THE BSC GROUP, INC.
WITNESSED BY:
BRUCE MURPHY
PERC. RATE:
N/A MIN./INCH
SOIL EVALUATOR
MARK DIBB
SOIL CLASS: SOIL CLASS:
1 1
L.T.A.R. L.T.A.R.
0.74 G.P.D./SQ.FT. 0.74 G.P.D./SQ.FT.
DATUM:
VERTICAL DATUM: ASSUMED
BENCH MARK SET: HYDRANT TAG BOLT EL = 83.84
PROFILE'. NOT TO SCALE ALL COMPONENTS H-20
EL.= A FIRST PIPE LENGTH
TOP FOUNDATION CONCRETE COVERS TO TO BE SET LEVEL
EL=85.2 FINISHED GRADE. FOR MIN. 2' FINISH GI�I'.ADE
EL=82.x;;; 84
4" VC SCH 40 4" PVC SCH 40
A PVf`.d _ +Y//�C� d/�'-"9ccaN9�� d7 I rtwrF - ANBER
A
LOAMY SAND
10YR 3/2
LOAMY SAND
10YR 5/6
EL = 82.6
MEDIUMI SAND
10YR 7/4 52"
C2
LOAMY
IND
COARSE SAND
10YR 7/3
16"
32"
56"
8"
EL = 73.6 140"
DATE:
9/29/05
TEST BY:
THE BSC GROUP, INC.
WITNESSED BY:
AMY VON HONE
PERC. RATE:
3 MIN./INCH
SOIL EVALUATOR
MARK DIBB
SOIL CLASS:
1
L.T.A.R.
0,74 G.P.D./SQ.FT.
SEPTIC TANK DETAIL: 1,500 GALLON H-20 DISTRIBUTION BOX DETAIL: NOT TO SCALE LEACHING DETAIL: H-20 NOT TO SCALE
NOT TO SCALE NO. OF OUTLETS 9
5. INLET AND OUTLET TEES TO BE CAST IRON4" PVC 42'5' �- 4'
NCTES, : 1. SEPTIC TANK SHALL BE STEEL FINISHED Gs ADE
SCHED. 40 PVC OR CAST -IN-PLACE CONCRETE. _ plpE o0 0 0 0 0 0 00 00 0 0 0 0 0 000 0 0 0 0 0 0 0 0 0
REINFORCED CONCRETE o 0 00 0 0 0° 0 0 0 000 0 0 0 0 0 0 0 0 0 0 0 0 0
2. SEPTIC TANK TO WITHSTAND H-20 LOADING TEES TO BE CENTERED UNDER MANHOLE COVER.
REMOVABLEE!5O
� 3" WALLS °0 5 UNITS a
COVER NOTES:
3. ALL PIPE CONNECTIONS AND CONCRETE 1 °
CONSTRUCTION SHALL BE WATERTIGHT. .": ' 5" 1. DIST. BOX TO WITHSTAND H-20 LOADING o O O 00 o056" 12'-10T P c BIER 2. PROVDE INLET TEE OR BAFFLE WHERE o 0 0 0 ON LEACHIFIG DRYWELLS o4. FlLL ALL UNUSED KNOCKOUTS WITH 2-24" DIA CONCRETE MANHOLES I I 1ISLOPE OF PIPE EXCEEDS 0.08 FT./FT OR 000000000 000000 0MORTAR. W/ METAL HANDLES BROUGHT o°oo 0 0 00 0 00000000 °
TO 6" OF FlNISH GRADE ?' T 20" IN PUMPED SYSTEM. 0 0 0 0 0 00000 0000 0 00000 0 000 000�• 8" 3. FIRST TWO FEET OF PIPE OUT OF DIST. F 50.5
TEE TO BE UNDER 12" MIN 6",BOX TO BE LAID LEVEL PLAN VIEW - LEACHING CHAMBERS
M.H. OPENING COVER
I o p p t o UQe e T 4. RECOMMENDED MANUFACTURER-ROTONDO
`npr4frwn�n4j a cp Oc% L
RAISE M.H W 6" - 4" OR APPROVED EQUAL
BOTTOM ON LEVEL /� LOAM &SEED DISTURBED AREAS
SEWER BRICK �:.-r._;:•_ ."-r STABLE BA E 6' MIN. 3/4" TO 5. ALL PIPE CONNECTIONS AND CONCRETE111111111111,11111171- 11111111111,,11111117777771111171171
�..._ 1D_p^ & MORTAR r: 12" :-• 1 1/2" CRUSHED CONSTRUCTION SHALL BE WATERTIGHT.
NORMAL WATER LEVEL CROSS -SEC ION STONE BASE 3' MAX. COMPACT*L16"MUM,12"MINIMUM
..,-, `t 6. FIT BREAKOUT BARRIER SNUG AROUND o o
3" D -BOX AND USE EPDXY RESIN FOR WATER o o O 0 3" LAYER
10" 14" S: T TIGHT SEAL p PEASTONE
PRECAST SEPTIC TANK INLET TEE = 5'-0 I 30. 7. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. 38" T p0 = = = � M REMOVE
24" O C� C� 0 UNSUITABLE
5'-0"4'-9" 4'-1' MIN 6'-0" PRECAST D!ST- EFFEC. Wo MATERIAL FOR
O 0 05' ALL AROUND
-LIQUID DEPTH 30" BOX / 1£' DEPTH ��yU6'-2" ( coN7Ra�) " DIAMETER S O O O =1 CLEANOU I ��n��BOTTOM ON LEVEL STABLE BASE ��`a 56"WASHED STONE
PLAN VIEW 6" 12'-10"
6" MIN. 3/4" TO //�d�f //�///Cy//CJ �S"- I-10"
1 1/2" STONE CROSS-SECTION VIEW PLAN VID1 CROSS-SECTION IOF CHAMBER
'.
/000'
DESIGN CRITERIA:
UP
DESIGN FLOW:
OF QJe��G _ HID BUILDING 8,490 S,F, OFFICE SPACE
a� oyG o o� 75 GPD/1000 S,F, OFFICE SPACE
�o MARK D. / °�• TOTAL FLOW = 637 G,P,D.
o DIBB
CIVIL
AIN .45937QQ \� /x�j "A
'%p FFG15TEP G�e\QI.' /.-• � {.$Oo ��i`,�
S ! AL
zce
R$
�/ V/O _ •.ter 1a PI `AE
UP
CB tk
41 Lp
n
0,<14" DEAD 5 6
PINE
°rya --. • �` ��� Q1 � \ % ,� 9 $ • - � \ _
J�TM6TION SYSTEM PROPOSED
INDICATES
V ES'1MAiED
SEI-SONAL HIGH
GROUND WATER
INDICATES
y OBSERVED
GROUND WATER
DN INDICATES
PERC.
TEST
®INDICATES
UNSUITABLE
MATERIAL
5OUTLET
DIST. BOX
SEPTIC TANK
INVERT ELEVATIONS:
REQUIRED SEPTIC TANK:
637 X 200% = 1274 GAL.
SEPTIC TANK PROVIDED: = 1500 GAL.
PROPOSED
85.87
A
4" INVERT AT BUILDING
83.00
B
VENT
82.50
C
4" INVERT AT SEPTIC TANK (OUT)
82.25
D
PROPOSED
50.5' X 12.8'
SOIL ABSORPTION
SYSTEM
EXISTING
BUILDING
/
/
E
4" INVERT AT DIST. BOX (OUT)
SIZE OF LEACHING FACILITY REQUIRED:
F
DESIGN PERC. RATE: 3 MIN./ INCH
LONG TERM APPL RATE 0,74 G.P.D/S.F.
637 GPD +. 0 74 GPD/SF - 861 S F
/ SIZE OF LEACHING FACILITY PROVIDED -
USE PRE -CAST CONCRETE
LEACHING CHAMBERS(5 UNITS) 12,8'X2'X50.5'
CO lIDEV'ALL = 2(12 8'+50 51) X 2' _
253
18' (2) 6' D -BOX
U
_EAC P �3. TONE TEST J,
ROUN'PIT f/}
I
}4" OAK ! IN
gp
0� GASPROPAN D BO YS g68. yp. 10•
OX 's y YQii w! % WATER ERVI ES ✓
�1 o. i r 066 RESERVE
UP / t !� 09: TEST O. - INFILTRATION SYSTEM.! #:
, ; PIT DIRT PIL $y 65 PTTEST , • , ' 42'X10' W/(5) 6- DIA.
LEACH PITS, 2' STONE
O ; 15 ROPOSED 1,500/ \ AROUND
11 11a TESi () 6� 85' GALLON SEPTIC <cP
J a` IT } PFIOPOSED �� AO 83 TANK P� INV ILP=74.
- 79.0
PIT Oy ., 2• STORY OFFICE?_ 2R• BUT LP=74.1
S.F.OFFICE BOT SYSTEM=72.
r /�0
jrx`8490y G
CB \ 0. BUILDING
600 C n `3 l / `'c,� '
TEST
PIT IS
s
14 ✓ oy� \.= f
o : - • � ye1 i" I FF=Bs o •--- Oo /+ -
/ �. / TOF=85.87
-: - 1 X - DIRT PILE`.
V I
`\
\ ��? \ 00 rn / y^� r P \ TEST
\ °S y \ cP O V PIT#3
LQ c�
SESEED
1/ J
=
\.- py10
GUY Cj/ OgL
o � / ,CD C3 C3
-
H V �15
PLAN VIEW P �
/�ii
17' SIPARATICN SCALE: 1' = 20 FEET \_
{'
EST. HIGH GROUNDWATER
oy
05 0 .
\.� � I ;., 5
U 0 10 20 40 FT.6k-
TOP OF FOUNDATION
85.87
A
4" INVERT AT BUILDING
83.00
B
4" INVERT AT SEPTIC TANK (IN)
82.50
C
4" INVERT AT SEPTIC TANK (OUT)
82.25
D
4" INVERT AT DIST. BOX (IN)
81.80
E
4" INVERT AT DIST. BOX (OUT)
81.63
F
INVERTS AT LEACCHING FACILITY:
ZONING DISTRICT. R-40 B-1
IMPERVIOUS MATERIAL
AT BEGINNING
4 INVERT,CHING CHAMBER
81.00
G BREAKOUT 81.50
OF LEA AT BOTTOM
SIDE 20' 25'
NOT CONTAIN ANY MATERIAL LARGER THAN
TING CHAMBER
79.00.
K
[L[Vp0N3SERVED DEPTH TP#6
62.0
J
8k9�
VARIANCES REQUESTED:
C /
NONE
ClQl
GHQ �.:- �
QQp� �P _ 85ay
OT
�� �p Gey \• - I� I \\\ go
BENCHMARK `. .�\ LNIF
G HYDRANT WESTSIDE REALTY TRUST /
TAG BOLT \ .. ASSESSORS MAP 143Iy
PARCEL 112 5"
- �
ASSUMED 44293tS.F. TOTAL 'N6
/
M i BOTTOM = 12,8' X 50,5' 646
899 S.F.
899
S,F
x 0,74 GPD/SF =
665 GPD
665
GPD
PROVIDED > 637
GPD REQUIRED
LOCUS INFORMATION
lIPL
CURRENT OWNER: WESTSIDE REALTY TRUST
GENERAL NOTES:
1. THIS PLAN IS FOR DESIGN AND
TITLE REFERENCE: BOOK 10025, PAGE 135
DISPOSAL FACILITY ONLY.
2. ALL CONSTRUCTION METHODS AND
PLAN REFERENCE: LC. 38339-8
D.E.P TITLE 5 AND LOCAL BOARD
OF HEALTH REGULATIONS.
BOOK 206, PAGE 45
OR TRAVELED WAY SHALL BE SCHEDULE
40 OR EQUAL.
ASSESSORS MAP: 143
LOCATED WITHIN 150 FT. OF THE
PROPOSED LEACHING FACILITY NOR
PARCEL: 112
150' OF ANY KNOWN LEACHING FACILITY.
5. WITHIN LIMIT OF EXCAVATION REMOVE
ZONING DISTRICT. R-40 B-1
IMPERVIOUS MATERIAL
6. REPLACE ALL EXCAVATED MATERIAL WITH
SETBACKS: FRONT 30' 30'
MATERIAL AND DELETERIOUS SUBSTANCES.
MIXTURES AND LAYERS OF DIFFERENT CLASSES
SIDE 20' 25'
NOT CONTAIN ANY MATERIAL LARGER THAN
TWO INCHES, A SIEVE ANALYSIS, USING A 04
REAR 20' 20'
REPRESENTATIVE SAMPLE OF FILL. UP TO 457
BY WEIGHT OF THE FILL SAMPLE MAY BE
MINIMUM LOT SIZE: 40,000 S.F. 25,000 S.F.
ALSO SHALL BE PERFORMED ON THE FRACTION
OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH
EXISTING TOTAL 44,293±S.F.
MATERIAL MEETS EACH OF THE FOLLOWING
SPECIFICATIONS:
LOT AREA:
(4.75 mm EFFECTIVE PARTICLE SIZE)
10%-1007 MUST PASS #50 SIEVE
FEMA FLOOD ZONE "C" AS SHOWN ON PANEL
07,207 MUST PASS #100 SIEVE
(0.15 mm EFFECTIVE PARTICLE SIZE)
ZONE DISTRICT. 250015 0001 D DATED 7/2/92
(0.075 mm EFFECTIVE PARTICLE SIZE)
'
OVERLAY DISTRICT: AQUIFER PROTECTION OVERLAY
THE CONTRACTOR SHALL BE RESPON-
SIBLE FOR PROPERLY LOCATING AND
PARTIAL: DISTRICT & ZONE II (PARTIALLY)
STRUCTION ACTIVITY WITH DIG -SAFE
AND THE APPLICABLE UTILITY -
COMPANY AND MAINTAINING THE
EXISTING UTILITY SYSTEM IN SERVICE.
DIG -SAFE SHALL BE NOTIFIED PER
' 34'XiCI
�u
LOCUS PLAN: NO SCALE
AT TEL. 1-888-344-7233. THE
LEAH P
THEIR ACCURACY OR THAT ALL
UTILITIES AND SUBSURFACE STRUCTURES
/dyyp d"r
ARCu, 0
INV
TAKEN FROM RECORD PLANS. THE
�s
wrt'.101.111 I. L':i..=i
AND STRUCTURES AS REQUIRED PRIOR '
eoTli
10 BOT.,
��PRIMMD
THE USE OF A GARBAGE GRINDER.
A GARBAGE GRINDER IS NOT
&,
ADVERSE IMPACTS TO THE LEACHING
FACILITY.
9. THE ENGINEER IS TO BE NOTIFIED OF
ANY FIELD CHANGES THAT MAY BE
REQUIRED.
BSC GROUP
657 Main Street, (RT. 28) Unit 6
W. Yarmouth Massachusetts
02673
508 778 8919
4
LOCUS,
SEWAGE DISPOSAL
SYSTEM
�l '��. N
4•a
APACHE DRIVE
YARMOUTH PORT
.. e .
PREPARED FOR:
f CE
6� �O FB
HA2 tiF
FQ
REVISIONS
NO. DATE DESCRIPTION
GENERAL NOTES:
1. THIS PLAN IS FOR DESIGN AND
CONSTRUCTION OF THE SEWAGE
DISPOSAL FACILITY ONLY.
2. ALL CONSTRUCTION METHODS AND
MATERIALS SHALL CONFORM TO MASS.
D.E.P TITLE 5 AND LOCAL BOARD
OF HEALTH REGULATIONS.
3. ALL PIPES LOCATED UNDER PAVEMENT
OR TRAVELED WAY SHALL BE SCHEDULE
40 OR EQUAL.
4. THERE ARE NO KNOWN PRIVATE WELLS
LOCATED WITHIN 150 FT. OF THE
PROPOSED LEACHING FACILITY NOR
ANY KNOWN WELLS PROPOSED WITHIN
150' OF ANY KNOWN LEACHING FACILITY.
5. WITHIN LIMIT OF EXCAVATION REMOVE
ALL TOPSOIL, SUBSOIL AND OTHER
IMPERVIOUS MATERIAL
6. REPLACE ALL EXCAVATED MATERIAL WITH
CLEAN GRANULAR SAND, FREE FROM ORGANIC
MATERIAL AND DELETERIOUS SUBSTANCES.
MIXTURES AND LAYERS OF DIFFERENT CLASSES
OF SOIL SHALL NOT BE USED. THE FILL SHALL
NOT CONTAIN ANY MATERIAL LARGER THAN
TWO INCHES, A SIEVE ANALYSIS, USING A 04
SIEVE, SHALL BE PERFORMED ON A
REPRESENTATIVE SAMPLE OF FILL. UP TO 457
BY WEIGHT OF THE FILL SAMPLE MAY BE
RETAINED ON THE #4 SIEVE. SIEVE ANALYSES
ALSO SHALL BE PERFORMED ON THE FRACTION
OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH
ANALYSES MUST DEMONSTRATE THAT THE
MATERIAL MEETS EACH OF THE FOLLOWING
SPECIFICATIONS:
1007 MUST PASS #4 SIEVE
(4.75 mm EFFECTIVE PARTICLE SIZE)
10%-1007 MUST PASS #50 SIEVE
(0.30 mm EFFECTIVE PARTICLE SIZE)
07,207 MUST PASS #100 SIEVE
(0.15 mm EFFECTIVE PARTICLE SIZE)
0%5% MUST PASS #200 SIEVE
(0.075 mm EFFECTIVE PARTICLE SIZE)
7. EXISTING UTILITIES WHERE SHOWN
IN THE DRAWINGS ARE APPROXIMATE,
THE CONTRACTOR SHALL BE RESPON-
SIBLE FOR PROPERLY LOCATING AND
COORDINATING THE PROPOSED CON-
STRUCTION ACTIVITY WITH DIG -SAFE
AND THE APPLICABLE UTILITY -
COMPANY AND MAINTAINING THE
EXISTING UTILITY SYSTEM IN SERVICE.
DIG -SAFE SHALL BE NOTIFIED PER
THE STATE OF MASSACHUSETTS
STATUTE CHAPTER 82, SECTION 409
AT TEL. 1-888-344-7233. THE
ENGINEER DOES NOT GUARANTEE
THEIR ACCURACY OR THAT ALL
UTILITIES AND SUBSURFACE STRUCTURES
ARE SHOWN. LOCATIONS AND
ELEVATIONS OF UNDERGROUND UTILITIES
TAKEN FROM RECORD PLANS. THE
CONTRACTOR SHALL VERIFY SIZE,
LOCATION AND INVERTS OF UTILITIES
AND STRUCTURES AS REQUIRED PRIOR '
TO THE START OF CONSTRUCTION.
8. THIS SYSTEM IS NOT DESIGNED FOR
THE USE OF A GARBAGE GRINDER.
A GARBAGE GRINDER IS NOT
RECOMMENDED DUE TO RECOGNIZED
ADVERSE IMPACTS TO THE LEACHING
FACILITY.
9. THE ENGINEER IS TO BE NOTIFIED OF
ANY FIELD CHANGES THAT MAY BE
REQUIRED.
BSC GROUP
657 Main Street, (RT. 28) Unit 6
W. Yarmouth Massachusetts
02673
508 778 8919
PROJECT TITLE:
DESIGN FOR
SEWAGE DISPOSAL
SYSTEM
APACHE DRIVE
YARMOUTH PORT
MASSACHUSETTS
PREPARED FOR:
PORTSIDE DEVELOPEMENT PARTNERS
C/0
BROWN, LINDQUIST, FENUCCIO
& RABER ARCHITECTS, INC.
203 WILLOW STREET
YARMOUTH PORT, MA 02675
DATE: DECEMBER 8, 2005
COMP. DESIGN: M. DIBB
CHECK: K. HEALY
DRAWN: M. DIBB
FIELD: D. GAZZOLO / J. McCARTIN
FILE NO. 8882-SEP.DWG
DWG NO. 5662-03
SHEET 1 OF 1
JOB NO. 4-8889-00