Loading...
HomeMy WebLinkAbout25.85 - Sewage Disposal System DesignE 0 .3 n Cc 0 " TEST PIT DME#1 GRD. EL. 11.4 GW. EL. 3.30 12" 60• 66` 120" ELEV. 5.90 C 109• v 1 114" v MEDIUM SAND 2.5y 7/4 ELEV. = 1.4 T 1 SEPTIC TANK DETAIL: 1,500 GALLON PIT DATA: DECEMBER 10, 2002 NOT TO SCALE 10" TEST PIT D E,42 GRD. EL. 9.6 TEST PIT BSC#1 TEST PIT BSC#2 GRD. EL. 8.3 GRD EL. 6.5 NOTES: 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. 2. SEPTIC TANK TO WITHSTAND H-10 LOADING UNLESS UNDER PAVEMENT DRIVES OR 5. INLET AND OUTLET TEES TO BE CAST IRON, TEESTO 0 PVC O RC UNDER LACE CONCRETE. 12` 60' 66' 120" ELEV. = 4.0 C 109• t 114• o MEDIUM SAND 2.5y 7/4 ELEV. _ (-.4) 120" GW EL 3 0 GW EL. 3.20 TRAVELED WAYS, WHEREIN H-20 LOADING A FOAMY SAN¢ F,LEV 9 = 144 10 ' •l,(fAMY SAND 22 ELEV. 6.5 42- 6y C, 90' _ FINE SAND 10yr 6/4 ELEV. _ (-1.7) 120' A LOAMY ,SAND ' 7,5 yr 4/j' LOAMY SAND, B :.- fi0.4' 6':, ELEV. = 4.70 39' C, 66' - FINE SAND 5yr 7/3 ELEV.= (-3.5) SHALL APPLY. 3. ALL PIPE CONNECTIONS AND CONCRETE 2-24" DIA CONCRETE MANHOLES CONSTRUCTION SHALL BE WATERTIGHT. r W/ METAL HANDLES BROUGHT 4 MFILL ALL ORTAR. UNUSED KNOCKOUTS WITH I TO 6' OF FINISH GRADE TEE TO BE UNDER I12" 1 M.H. OPENING COVE 14.1 1 1/2" STONE 10'-6" RAISE M.H Wf ► 10" SEWER BRICK 12/10/02 do MORTAR C NO. OF OUTLETS 5 NOR! 6` MIN. 3/4' TO/'�'`d CROSS-SECTION VIEW A UA It: UA IE: PRECAST SEPTICTANK DATE: 14.1 1 1/2" STONE a 10" 14' 12/10/02 10.95 C NO. OF OUTLETS 5 10.70 D 30.0 -r INLET TEE TEST BY: TEST BY: TEST BY. TEST BY. _ c_4'-0" / W-2" 4'-6` DEMAREST-McL. THE BSC GROUP MIN. W BM ON rr WITNESSED BY: - WITNESSED BY: 5'-8" K 35 PLAN VIEW - Farlalnlr, CHAMRFRC LOAM &SEED DISTURBED AREAS LIQUID DEPTH 1 � LYNN MULKEEN LYNN MULKEEN STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY J_ EXISTING UTILITY SYSTEM IN SERVICE. _ r PERC. RATE: PERC. RATE: PERC. RATE: PERC. RATE: THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES I HIGHPOINT IN ROADWAY i MIN./INCH MIN,/INCH E_ MIN./INCH b c THE USE OF A GARBAGE GRINDER. BOTTOM ON LEVEL STABLE BASE ELEV. 10.79 PLAN VIEW FACIUTY. SOIL EVALUATOR 6` MIN. 3/4' TO/'�'`d CROSS-SECTION VIEW A UA It: UA IE: DATE: DATE: 14.1 1 1/2" STONE 6/24/98 6/24/98 12/10/02 12/10/02 10.95 C NO. OF OUTLETS 5 10.70 D 30.0 10.60 FINISHED GRADE TEST BY: TEST BY: TEST BY. TEST BY. DISTRICT: / DEMAREST-McL, DEMAREST-McL. THE BSC GROUP THE BSC GROUP NOTES: rr WITNESSED BY: WITNESSED BY. WITNESSED BY: WITNESSED BY. 4 UNITS °°°°°°00000°000 °°° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 35 PLAN VIEW - Farlalnlr, CHAMRFRC LOAM &SEED DISTURBED AREAS AMY VON HONE AMY VON HONE LYNN MULKEEN LYNN MULKEEN STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY 20 0 0 0 EXISTING UTILITY SYSTEM IN SERVICE. _ r PERC. RATE: PERC. RATE: PERC. RATE: PERC. RATE: THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND HIGHPOINT IN ROADWAY i MIN./INCH MIN,/INCH -S_Z_-MIN./INCH MIN./INCH 8, THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT ELEV. 10.79 r FACIUTY. SOIL EVALUATOR SOIL EVALUATOR SOIL EVALUATOR SOIL EVALUATOR W. Yarmouth (Massachusetts r DEMAREST-McL. DEMAREST-McL. CRAIG FIELD CRAIG FIELD X54 r SOIL CLASS: SOIL CLASS: SOIL CLASS: SOIL CLASS: CIII PREPARED' FOR- �� 1 1 �_ 1 MASSACHUSETTS 02465 DATE: DECEMBER 16, 2002 COMP. DESIGN: K. HEALY CHECK: D. CRISPIN DRAWN: P. HAGIST FIELD: D. GAZZOLO /R. FITZPATRICK it I DISTRIBUTION BOX DETAIL: NOT TO SCALE LEACHING DETAIL NOT TO SCA 5'- 5'-8- 15 'I5'-8 15 1/2` 3 10 /2' PRECAST DIST. BOX i --r\ T 17 -14 PLAN VIEW \ N/F X12_ _ BETTY L. LECLAIR ASSESSORS MAP 25 581'00'00"E PARCEL 84 � _ -J �oI� i ~ "'000- 1 20' L.T.A.R. L.T.A.R. L.T.A.R. L.T.A.R. \ / 0.74 G.P.D./SQ.FT. G.P.D./SQ.FT. 0,74 G.P.D./SQ.FT. G.P.D./SQ.FT. f w �r INDICATES INDICATES INDICATES 1 UNSUITABLE PERC.y ESTIMATEDy INDICATES r \ LLJ MATERIAL TEST SEASONAL HIGH OBSERVEDLIMITS OF 1� 82" GROUND WATER GROUND WATER r r a r f i EXCAVATION 10 Q oQ j t SEE NOTES 5 & 6 40.1 HIGH GROUNDWATER COMPUTATION HIGH GROUNDWATER COMPUTATION rrr o w 1 /� 11 , (BASED ON DME-TP#1 BASED ON BTC---TP-#-2-y-w o S / z�m 12.0 / DEPTH TO WATER 114" DEPTH TO WATER 6.5 r O w r DME#1 iQ �iy J BSC#1 I INDEX WELL MIW-29 INDEX WELL MIW-29 0� r r 40-1 f " � N -� / WATER LEVEL RANGE ZONE A WATER LEVEL RANGE ZONE A o /N CURRENT DEPTHCINDEX WELL(6/98 6.7 CURRENT DEPTHOINDEX WELL(11/02) 9.2 f WATER LEVEL ADJUSTMENT 0.7 WATER LEVEL. ADJUSTMENT 2.3 ry J f O / / DEPTH TO ADJUSTED HIGH WATER 6.0 DEPTH TO ADJUSTED HIGH WATER 3.2 __ DATUM: VERTICAL DATUM: N.G.V.D. BENCH MARK SET: HYDRANT TAG BOLT ELEV.=12.69 PROFILE: NOT TO SCALE EL.= A TOP FOUNDATION CONCRETE COVERS TO WITHIN EL= 12.5 6' OF FINISHED GRADE. 1=C I 5 OUTLET DIST. BOX SEPTIC TANK INVERT ELEVATIONS: BOOK 438, PAGE 45 ASSESSORS MAP: TOP OF FOUNDATION 14.1 A . LE B 4" INVERT AT SEPTIC TANK (IN) 10.95 C NO. OF OUTLETS 5 10.70 D 30.0 10.60 FINISHED GRADE 4" INVERT AT DIST. BOX (OUT) 10.43 F INVERTS AT LEACHING FACILITY: DISTRICT: PANEL # 250015 0006 D REMOVABLE COVER LAND SUBJECT TO SIEVE ANALYSIS: 2• WALLS NOTES: 00 0 0 oo 0 o 0 0 ° 0 0 0 0 0 0 0 0 0 0 0 0 0 D -75-0---o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .9:'9 ••�.r: •9..�,9f•9••••�: N.:: 2' nuc aAdeEtt 1 15' _ T 6 . 5,5' OUTLETS • 8' 1 ��• n$°•n $�� � $•n$a��< L BOTTOM ON LEVEL 2' STABLE BASE 6' MIN. 3/4' TO CROSS-SECTION 1 CRUSHED STOONENE BASE 1. DIST. BOX TO WITHSTAND H-10 LOADING UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS WHEREIN H-20 LOADING SHALL APPLY. 2. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR IN PUMPED SYSTEM. 3. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL 4• ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. ° o0 ° °°°°°°°°°° 4 UNITS °°°°°°00000°000 °°° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 35 PLAN VIEW - Farlalnlr, CHAMRFRC LOAM &SEED DISTURBED AREAS ESTIMATED HIGH GROUNDWATER 3' MAX. COMPACTED FILL 36" MAX., 9"MIN. J COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY 20 0 0 0 EXISTING UTILITY SYSTEM IN SERVICE. 5'- 5'-8- 15 'I5'-8 15 1/2` 3 10 /2' PRECAST DIST. BOX i --r\ T 17 -14 PLAN VIEW \ N/F X12_ _ BETTY L. LECLAIR ASSESSORS MAP 25 581'00'00"E PARCEL 84 � _ -J �oI� i ~ "'000- 1 20' L.T.A.R. L.T.A.R. L.T.A.R. L.T.A.R. \ / 0.74 G.P.D./SQ.FT. G.P.D./SQ.FT. 0,74 G.P.D./SQ.FT. G.P.D./SQ.FT. f w �r INDICATES INDICATES INDICATES 1 UNSUITABLE PERC.y ESTIMATEDy INDICATES r \ LLJ MATERIAL TEST SEASONAL HIGH OBSERVEDLIMITS OF 1� 82" GROUND WATER GROUND WATER r r a r f i EXCAVATION 10 Q oQ j t SEE NOTES 5 & 6 40.1 HIGH GROUNDWATER COMPUTATION HIGH GROUNDWATER COMPUTATION rrr o w 1 /� 11 , (BASED ON DME-TP#1 BASED ON BTC---TP-#-2-y-w o S / z�m 12.0 / DEPTH TO WATER 114" DEPTH TO WATER 6.5 r O w r DME#1 iQ �iy J BSC#1 I INDEX WELL MIW-29 INDEX WELL MIW-29 0� r r 40-1 f " � N -� / WATER LEVEL RANGE ZONE A WATER LEVEL RANGE ZONE A o /N CURRENT DEPTHCINDEX WELL(6/98 6.7 CURRENT DEPTHOINDEX WELL(11/02) 9.2 f WATER LEVEL ADJUSTMENT 0.7 WATER LEVEL. ADJUSTMENT 2.3 ry J f O / / DEPTH TO ADJUSTED HIGH WATER 6.0 DEPTH TO ADJUSTED HIGH WATER 3.2 __ DATUM: VERTICAL DATUM: N.G.V.D. BENCH MARK SET: HYDRANT TAG BOLT ELEV.=12.69 PROFILE: NOT TO SCALE EL.= A TOP FOUNDATION CONCRETE COVERS TO WITHIN EL= 12.5 6' OF FINISHED GRADE. 1=C I 5 OUTLET DIST. BOX SEPTIC TANK INVERT ELEVATIONS: BOOK 438, PAGE 45 ASSESSORS MAP: TOP OF FOUNDATION 14.1 A 4" INVERT AT BUILDING 11.31 B 4" INVERT AT SEPTIC TANK (IN) 10.95 C 4" INVERT AT SEPTIC TANK (OUT) 10.70 D 4" INVERT AT DIST. BOX (IN) 10.60 E 4" INVERT AT DIST. BOX (OUT) 10.43 F INVERTS AT LEACHING FACILITY: DISTRICT: PANEL # 250015 0006 D 4" INVERT AT BEGINNING LAND SUBJECT TO SIEVE ANALYSIS: OF LEACHING CHAMBER 10.3 G ELEVATION AT BOTTOM SWAN PASS No. 200 1 OF LEACHING CHAMBER 8.3 H ESTIMATED HIGH GROUNDWATER 3.3 J VARIANCES REQUESTED: NONE ij C.5 13.0 / 13.2 -megPROP I / r / OSED Q rr 2 CAR GARAGE Q FIRST PIPE LENGTH x 4 TO BE SET LEVEL f If 1,500 VC , FOR MIN. 2 EL.IS' GRADE r O\� ZGNj� &0 �O �� W 1 GAL 4' PVC SCH 40 °ok2oNE TANK LEACHING CHAMBER - 0.o':: CL / 0 MIN.: - H /40 :.� D" 5' SEPARATION // r BOX20 0, W / PROPOSED o I f ^� �1<5 MIN, / 4 BEDROOM -40 / °' 1 EST. HIGH GROUNDWATER I r `` / / DWELLING / J / / #54 ASPINET ROAD I r,,, TDF. 14.1 PROP. f o / BASE. SLAB 10.1 STONE PROPOSED r r fRaj ESERVE f / PATIO r r i DME#2/ / / / BSC#2 /- ET, VIA L ( 1r BASKETB L \ HOOP / 10' , \ THH IN , e� 1 26.1 EAKOUT 10.8 / A� SED r W _r E \4 7.o 1 PROPPSED S� r HYDRANT TAG BOLT �✓ e DRYWEIA, rr PLAN VIEW NSF \ \ \ DAVID SEMENTELLI J r SCALE: 1' = 10 FEET ASS A 25 PARCEL \ II0 5 10 20 DAVID J. CRISPIN �n CIVIL No. 32112 N/F RICHARD SEMENTELLI TR. ASSESSORS MAP 25 PARCEL 85 15,414±S.F. 1 � Vim• t` J PROPOSED j DRYWELL 3 i o DW Do 3 M ti ti Q. 0 I � O �N 4 e�N 20 z itV 1 - - f oWa� Q rn 0 N/F O DAVID W. SMARZ ASSESSORS MAP 25 PARCEL 78 U3 ;o h v� N/F EDWARD J. SCHAFER ASSESSORS MAP 25 ..77 S: ' N/F CHARLEEN BRENNAN ASSESSORS MAP 25 PARCEL 76 o° ° oa BOOK 438, PAGE 45 ASSESSORS MAP: o SIZE OF LEACHING O REQUIRED: SETBACKS: 0° 50" 12' SIDE 15' o REAR 20' SIZE 0 FACILITY PROVIDED: °° 0°0 NOT IN A ZONE II FLOOD AN ZONE _ ZONE A-12 ELEV 10 DISTRICT: PANEL # 250015 0006 D 2% SLOPE MIN. rj 3:1 15' MIN 3" LAYER PEASTONE REMOVE UNSUITABLE MATERIAL FOR 5' ALL AROUND -3/4- - 1 1/2' WASHED STONE DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT110G.P.B./D 440 G.P.D. REQUIRED SEPTIC TANK: 440 X 200% - 880 GAL. SEPTIC TANK PROVIDED: = 1500 GAL. USE 4 HIGH DENSITY POLYETHYLENE LEACHING CHAMBERS 12'x2'x35' SIDEWALL = 2' (12'+35') X 2 = 188 S,F, BOTTOM = 12' X 35' = 420 S.F. I 608S,F, 608 SF x 0,74 GPD/SF = 449 GPD LOCUS INFORMATION CURRENT OWNER: RICHARD SEMENTELLI TR. TITLE REFERENCE: BOOK 11623, PAGE 327 PLAN REFERENCE: BOOK 438, PAGE 45 ASSESSORS MAP: 25 SIZE OF LEACHING FACILITY REQUIRED: SETBACKS: DESIGN PERC. RATE: <2 MIN./ INCH LONG TERM APPL. RATE 0.74 G.P.D/S.F. 440 GPD + 0,74 GPD/SF = 596 S.F. D.E.P TITLE 5 AND LOCAL BOARD SIDE 15' 3. ALL PIPES LOCATED UNDER PAVEMENT REAR 20' SIZE OF LEACHING FACILITY PROVIDED: OVERLAY DISTRICT. USE 4 HIGH DENSITY POLYETHYLENE LEACHING CHAMBERS 12'x2'x35' SIDEWALL = 2' (12'+35') X 2 = 188 S,F, BOTTOM = 12' X 35' = 420 S.F. I 608S,F, 608 SF x 0,74 GPD/SF = 449 GPD LOCUS INFORMATION CURRENT OWNER: RICHARD SEMENTELLI TR. TITLE REFERENCE: BOOK 11623, PAGE 327 PLAN REFERENCE: BOOK 438, PAGE 45 ASSESSORS MAP: 25 PARCEL: 85 ZONING DISTRICT: R-25 SETBACKS: FRONT 30' D.E.P TITLE 5 AND LOCAL BOARD SIDE 15' 3. ALL PIPES LOCATED UNDER PAVEMENT REAR 20' MINIMUM LOT SIZE: 25,000 S.F. EXIST. TOTAL LOT AREA: 15,414 S.F. OVERLAY DISTRICT. NOT IN A ZONE II FLOOD AN ZONE _ ZONE A-12 ELEV 10 DISTRICT: PANEL # 250015 0006 D OR OTHER CLEAN GRANULAR SOILS LAND SUBJECT TO SIEVE ANALYSIS: COASTAL STORM FLOWAGE LOCUS PLAN: N❑ SCALE PASS No. 100 I SWAN PASS No. 200 1 POND N M 7. EXISTING UTILITIES WHERE SHOWN \ S \TReET THE CONTRACTOR SHALL BE RESPON- 4,j 4,j � 2 4,j 4 oe Q 441 � 3 4,j 2. , SOUTH SHORE DRIVE REVISIONS NO. DATE DESCRIPTION 1. 1/29/03 PLAN. BRD. RESR REMOVE FULL BASEMENT GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL 6. REPLACE WITH CLEAN WASHED SAND OR OTHER CLEAN GRANULAR SOILS CONFORMING TO THE FOLLOWING SIEVE ANALYSIS: 10% (MAX) BY WE SHALL PASS No. 50 SIEVE <10 % OF No. 4 SIEVE SHALL PASS No. 100 I <5 % OF No. 4 SIEVE SHALL PASS No. 200 1 UNIFORMITY COEFFICIENT O No. 4 SIEVE </=6.0 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTIUTIES AND STRUCTURES AS REWIRED PRIOR TO THE START OF CONSTRUCTION. 8, THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACIUTY. BSC GROi[A 657 Main Street, (RT. 28) Unit 6 W. Yarmouth (Massachusetts 02673 508 778 8919 PROJECT TITLE: SEWAGE DISPOSAL SYSTEM DESIGN X54 ASPINET ROAD YARMOUTH MASSACHUSE S CIII PREPARED' FOR- �� JENNIFER SEME 24 MARION STREE NEWTON MASSACHUSETTS 02465 DATE: DECEMBER 16, 2002 COMP. DESIGN: K. HEALY CHECK: D. CRISPIN DRAWN: P. HAGIST FIELD: D. GAZZOLO /R. FITZPATRICK FILE NO. 8491SEP1.DWG DWG N0. 5135-04 SHEET 1 of 1 JOB N0.4-8491.00