Loading...
HomeMy WebLinkAbout17.123.1 - Site and Sewage PlanSYS. a.,• T.O.F. AT EL. 10.75' B A —ACCESS COVER To WrMW C OF RN, GRADE SEPTIC PROFILE TEST HOLE LOGS N9w �. Paacezz ACCESS COVER (wATERTIMM To l"arm 9ruE) ASSESSORS MAP 13 PARCEL H7 -10D MINIMUM .75' OF COVER WITHIN Ir OF FIN, ORAE ENGINEER: O.A. OJALA, S.E. ZONING DISTRICT: OVER PRECAST WITNESS: RICK JUDD R25 (CURRENT) B Note: Y drop In septic an n 2X SLOPE REQUIRED OVER SYSTEM YARD SETBACKS: E 8.44'+ S tem A RUN PIPE LEVEL ('s.5' ' PERC. RATE _ < 2 MIN/IN FRONT = 3O' / FOR FIRST r 2' DOUBLE WASHED PE4STONE A7.48"' PROPOSED 1500 7.71' B B i B 3 MAX.CLASS I SOILS GATE 9 20 97 510E _ J' •A 8 7.96' TANK (H CALLONS EPTIC f 10) �9Z"` GAS ---Z i__ ELEV. REAR = 20 ti aA��E 7.6' Q A 0.1.25- — � 8.3 _ PLAN REF. - 87/77 I CRUSHED STONE OR MECMANICAC 0 B. o F7.5Y;R FLOOD ZONE: Al2 ELEV. **EXIST COMPACTION. (15.221 (21) 7� Y INVERT T DEPTH OF : FLOW a 4_ (1_z SLOPE) A 6 s B SEPTIC DESIGN: (GARME DISPOSER IS NOT ALLOWED ) 6.76PROP.INET 'oEPrH = 14 3/4" TO 1 1/2" DOUBLE WASHED STONE DESIGN FLOW: 6 BEDROOMS (110 GPO) = 660 GPD C -^ INVERT OUTLET DEPTH = 19' 5. USE A 660 GPD DESIGN FLOW ELEV. SYSTEM A 11' SYSTEM A NOTE: NO D'BOX IN SYSTEMA 8 SEPTIC TANK: 860 GPD (2 YI .Ry, FOUNDATION— -- SEPTIC TANK 15, 4' L.S. USE A 1500 GALLON SEPTIC TANK SYSTEM B 24' D' BOX ---- LEACHING SYSTEM B 20• 6' FACILITY 4.16' 10 YR 5/6 LEACHING: LOCATION MAP SCALE 1 ;?ooa t O 20 6.6 SIDES: C BOTTOM: 34 x 2T (.74) 67911 uryvo rr BOARD of EFAVIM 2.6 M.S. TOTAL 918 S.F. 679 GPD s 2.5Y 7/6 USE 34' X 2T LEACH. FIELD OF 4 .ROWS OF 5 STD. APPR�ovF,n DATE ` ' / INFILTRATORS EACH WITH 3' OF STONE BETWEEN � O 2.6 ROWS AND AT EDGES AND 1,5 AT ENDS N obs. water I� _ � NOTE: NOTES: BUILDING SEWER EXIT " PIPE MUST BE RAISED BY 120 NGVD 1. DATUM IS PLUMBER TO 27 3/4" BELOW 2. MUNICIPAL WATER IS EXISTING ` �Z TOP OF FOUNDAl10N • 97.50 120' 3. MINIMUM PIPE PITCH TO BE 1/8" PER FC'OT, \ (PER DEED) \ s / 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10 PAVED (� \ rr \ 5. PIPE JOINTS TO BE MADE WATERTIGHT. DRIVE . l - � �O y fT��y `) 1 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. 9 %Tfi4LF OF�L'QT 11 �� ENVIRONMENTAL CODE TITLE V. \ 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE 22,013 s.f. +/— \ 1 / USED FOR LOT LINE STAKING. EXIST. DUPLEX (TO CURRENT ) 1 / 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. IL WETLAND LINE 1 I CP ( ) 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT _ 2 �f10 - ( I -_ . / _ ..INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED \ 1 ! FROM BOARD OF HEALTH -, 3 QEDROOM/ DECK 6 ST \ i 1 TO, PUMP ac"REMOVE.•(OR I D) EXFILL.'W CLEAN SAN � SYSTEM B / / \ SYSTEM B ISTING CESSPOOLS. "MAXIMUM FEASIBLE COMPLIANCE" S17E AND SEWAGE PLAN l2Gd{ 1 'SYSTEM A/ 8.5 I OF \I UNITS 10 & 12 LOT 10C "� K \ ST I ► j �, { t' ` 1102 �ll(c IN THE TOWN .(WEST) YARMOUTH 13 VSO / a 8 I p ` 1 PREPARED FOR: EXIST. J 1 3a 00 r f , DIANE MOUDOURIS SEPTITANK C 1 j NOTE. NO `\ I , O 2O ..�0------2 E 40 60 /or I D'BOX IN \ t 1 1 MOVE) ; SYSTEM A — \ p 1 J " = 20' JANUARY 10, 1998 Ti�1V�y��x1{ GARAGE USE "T" \ \ ^ 1, SCALE: 13,5 13.5 l DATE: \ 1 � _.. \ - � � � ,f{' QfcU. 3"9%9 ,/.tee o•,ja J' TTT aWc EXIST. LEACH PN' (PUMP AND FILL WITH \ / SAND OR I REMOVEy � � t � 508-382-4541 53' TREE go WS 382-se LOT 10D �-- - - 15513 sq.ft SHED (✓ / TH 1 ` 1 1` AL down cape engineering, inc. 3 0.36 Acres 1 CIVIL ENGINEERS LAND SURVEYORS 939 main st. Yarmouth, ma 02675 97.50 \ l LOT IOD P. SOUTHERLY HALF OF LOT 11 TBM — TOP COMBINED -UPLAND 37,526 S.F. OF CONIC. BND EL =; 8.90 (NGVD) JOB# 97-287 255' (PER 1 + DEED) t 15.2 xi' i ` � O'N�atL J5� p ,,a SYSTeM b. CT" dH�C! i��rGaO� I