HomeMy WebLinkAbout21 Atlantic Ave - Floor PlanARCH REFERENCE:
ARCHITECT APPROVAL:
0
0
WALL LEGEND
Existing interior wall
t^— Newinteriorwall
Existing CMU wall
a
M
N
P. J. CORMIER ARCHITECTURAL MILLWORK, INC.
14 Atlantic Avenue
South Yarmouth, MA 02664
508.760.2695
Remove existing exhaust fan and infill wall.
IF
---J`—I---
I {
I
I
Paint spray exhaust system
Mfgr. AFC Inc. Model No. EB2026-42
Letter of NFPA compliance attached. ---
I
6" concrete bui m containment area II
I Q @ concrete floor. Paint storage II
aabove in cabingts. II
1 11 11
I II II
I II 11
I II PA NT ROOM p
I II sq. ft
II NOTE; II
I
II Paint spray oom walls and ceiling II
I II to have 2 layers of Type "X" 5/8" II
II GWB. Shee to have minimum 24"11
1 overlap of a I seams. Use fire rated II
I I tape and ski coat. II
0'-61/2" j_
I
1
1
1
:/:1
ASSEMBLY ROOM
621 sq, ft.
NOTE;
Assembly room, Hall and Bathroom
walls and ceiling to have 1 layer of
Type "X" 5/8" GWB. Sheets to have
minimum 24" overlap of all seams.
Use fire rated tape and skim coat.
w
(�
0
II
I II BATH
O
N
-------------------------------
- Makeup air
Motorized I
interlocked
I
suppression
---- 10'-0"x10'-0" 0. H. Door
2868
PROJECT. 21 A ATLANTIC AVE.
1 FS7
----A3
HALL
88E.ft.
ORI
Automatic dry chemical fire suppression system
above. Contractor Ralph J. Perry Inc. to permit and
— — — J install system. System approved by Yarmouth
Fire Dept.. (Dept. Chief Raiskio has reviewed plans
and toured site)
7
r- ---
I I
IL - \� 24"x30" access skuttle to attic above hall.
Dry chemical fire suppression system location.
Metal filter \
doors by AFC j ---- 24"x3o" access skuttle to main
Inc. I attic.
through roof.
and fire
Plan, Proposed Paint/Assembly Rooms (1239 sq. ft.)
Scale: 1/4" = V -0'I
LOCATIdN: 21 ATLANTIC AVE, SOUTH YAROUTH
TITLE:
FINISHING / ASSEMBLY ROOM
PROPOSED PLAN
E
MAR 1 1 2005
BUILDING D; -PT,
DATE THIS SHEET:
15 FEB 05
LAST REVISION THIS SHEET:
REV.- N/A
�� 1
Ak >..�