Loading...
HomeMy WebLinkAbout17 Aunt Ediths Road - Sewage Disposasl Plan 2SOIL TEST PIT DATA: TEST PIT - #1 GRD. EL. 11.4 EST. HIGH GW. 2.8 A LOAMY SAND 10YR 4/2 LOAMY SAND 10YR 4/6 EL = 8.7 70" FINE CSAND 10YR 8/2 MEDCSAND 10YR 7/4 0 32" 98" 102" EL = 1.0 DATE: SEPT. 1, 2005 TEST BY. THE BSC GROUP, INC. WITNESSED BY: AMY VON HONE, R.S. PERC. RATE: 2 MIN./INCH SOIL EVALUATOR MARK DIBB, P.E. SOIL CLASS: SEPTEMBER 1, 2005 HIGH GROUNDWATER COMPUTATION (BASED ON TP#1) DEPTH TO WATER 10.4 INDEX WELL MIW-29 WATER LEVEL RANGE ZONE A CURRENT DEPTHOINDEX WELL(8/05) 8.4 WATER LEVEL ADJUSTMENT 1.8 DEPTH TO ADJUSTED HIGH WATER 8.6 INDICATES _g- ESTIMATED SEASONAL HIGH GROUND WATER INDICATES _SL OBSERVED GROUND WATER En Vm INDICATES DN PERC. TEST EINDICATES UNSUITABLE MATERIAL 0.74 G.P.D./SQ.FT. DATUM: VERTICAL DATUM: NGVD BENCH MARK SET: TOP OF FOUNDATION ELEVATION 12.5 PROFILE: NOT TO SCALE EL.= A FIRST PIPE LENGTH TOP FOUNDATION CONCRETE COVERS TO WITHINTO BE SET LEVEL EL. - 11.8 6" OF FINISHED GRADE. FOR MIN. 2' FINISH GRADE EL =? :.3-11.8 7 1,eVC SCH 40 �10110061wklffk�iIle 5 OUTLET>I I=F I DIST. BOX 5 SEPARATION SEPTIC TANK IEST. HIGH GROUNDWATER J INVERT ELEVATIONS: TOP OF FOUNDATION 12.5 A m x 4" INVERT AT BUILDING 10.85 B SLEEVED 4" INVERT AT SEPTIC TANK (IN) 10.57 C z Z 4" INVERT AT SEPTIC TANK (OUT) 10.32 D c' 4" INVERT AT DIST. BOX (IN) 10.00 E 0 0 4" INVERT AT DIST. BOX (OUT) 9.83 F m INVERTS AT LEACHING FACILITY: 13.6' mZ 4" INVERT AT BEGINNING PLAN REFERENCE: PLAN BOOK 184, PAGE 131 OF LEACHING CHAMBER 9.80 G BREAKOUT 10.3 ELEVATION AT BOTTOM PARCEL:- 98 OF LEACHING CHAMBER 7.80 H RS -40 ADJUSTED SETBACKS: FRONT 30' GROUNDWATER 2.80 J SIDE 20' OBSERVED GROUNDWATER 1.0 REAR 20' VARIANCES REQUESTED: • 40,000 S.F. TOWN OF YARMOUTH: EXISTING LOT AREA: 21,076± S.F. TO ALLOW THE TOP OF FOUNDATION TO BE 1.0' ABOVE THE HIGH POINT IN THE ROADWAY IN LIEU OF 2.0'. THIS WOULD ALLOW THE GARAGE TO BE MAINTAINED. ZONE: NOT A ZONE II TITLE 5: FEMA FLOOD AT TEL 1-888-344-7233. THE TO ALLOW THE 4" PVC PIPE TO BE LESS THAN 10' TO THE WATER LINE. THE SEWER LINE WILL BE 4' FROM WHERE BOTH LINES EXIT THE DWELLIN( AND WILL BE SLEEVE FOR ITS ENTIRE LENGTH. CONTRACTOR SHALL VERIFY SIZE. FLOOR PLANS: HITECTURAL PLANS SEE ATTACHED ARC SEPTIC TANK DETAIL: 1,500 GALLON DISTRIBUTION BOX DETAIL: NOT TO SCALE LEACHING DETAIL: NOT TO SCALE " NOT TO SCALE NO. OF OUTLETS rJ 4" PVC PIPE 15' - 1818 NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON, FINISHED GRADE :E REINFORCED CONCRETE. SCHED. 40 PVC OR CAST -IN-PLACE CONCRETE. 2. SEPTIC TANK TO WITHSTAND H-10 LOADING TEES TO BE CENTERED UNDER MANHOLE COVER. REMOVABLE 12" WALLS NOTES: °°O o0 0°° o0 0 00 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 UNLESS UNDER PAVEMENT, DRIVES OR COVER 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0° TRAVELED WAYS, WHEREIN H-20 LOADING o 0 4 UNITS 00 SHALL APPLY. ;vr:v..+,a:.o..+.v v.... i •v.:: ' 2" PVC BARRKR 1. DIST. BOX TO WITHSTAND H-10 LOADING o 3. ALL PIPE CONNECTIONS AND CONCRETE T T UNLESS UNDER PAVEMENT, DRIVES OR oo O HIGH°DEN TTY O o 50" 12' CONSTRUCTION SHALL BE WATERTIGHT. 2-24' DIA CONCRETE MANHOLES I TRAVELED WAYS WHEREIN H-20 LOADING 0 o POLYETH NE INA TRATOR 305 0 W METAL HANDLES BROUGHT 1 15" SHALL APPLY. 0 0 4. FILL ALL UNUSED KNOCKOUTS WITH 6 T o 00 0 0 00 0 0 0 0 0 0 0 0 0° 0 0 0 0 0° 0 0 0 0 0 0 0 T 6' OF FINISH GRADE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MORTAR. TEE TO BE UNDER 12" MIN. 6' S,5' OUTLETS 8" 1 2• PROVIDE INLET TEE OR BAFFLE WHERE M.H. OPENING SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR F - 35' �3' �dan�°A�v 4 d ��a e�$aYb'd'a FI PUMPED SYSTEM. PLAN VIEW - LEACHING CHAMBERS RAISE M.H W/. 2" 3. FIRST TWO FEET OF PIPE OUT OF DIST. 4' BOTTOM ON LEVEL LOAM &SEED DISTURBED AREAS 10'-6" SEWER BRICK STABLE BASE 6' MIN. 3/4" TO BOX TO BE LAID LEVEL d: • ,<•e =.- `.•: 1 1 /2" CRUSHED 10'-0' Ec MORTAR CROSS-SECTION 4. ALL PIPE CONNECTIONS AND CONCRETE NORMAL WATER LEVEL 12" STONE BASE CONSTRUCTION SHALL BE WATERTIGHT. 3' MAX. COMPACTED FILL 36" MAXIMUM 12"MINIM M edT 3. - 1 ° 00 00 0 0000 00 00 PRECAST SEPTIC TANK C 10"1TINLET TEE � 5'-1" DO O 5-2. 4'-6" ' 4'-0" MIN. •a Bow a 5'-8" 15 1/2' 5'-8" I LIQUID DEPTHET TEE J 0ON7BoW d PLAN VIEW ddb'-. •08..: 0L 4: Od..: _a ..�: d:•add _L Ito BOTTOM ON LEVEL STABLE BASE 6' MIN. 3/4' TO A dZ- �' CROSS-SECTION VIEW 1 1/2" STONE RICHARD F. ZEOLI, TRUSTEE ASSESSORS MAP 51 PARCEL 99 30 1/2' PRECAST DIST. BOX T T '7 1-/2' PLAN VIEW U.POLE m x 2 .6' - GENERAL NOTES: N 0 RI z Z D D.E.P TITLE 5 AND LOCAL BOARD c' O . 0 0 vm LOCATED WITHIN 150 FT. OF THE m ;0InN . 13.6' mZ 00 Z PLAN REFERENCE: PLAN BOOK 184, PAGE 131 m N D ASSESSORS MAP: m DEPTH PARCEL:- 98 O>m N � (n ZONING DISTRICT. RS -40 Ln SETBACKS: FRONT 30' C MATERIAL MEETS EACH OF THE FOLLOWING SIDE 20' 100% MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) REAR 20' 4-147 • 40,000 S.F. ddb'-. •08..: 0L 4: Od..: _a ..�: d:•add _L Ito BOTTOM ON LEVEL STABLE BASE 6' MIN. 3/4' TO A dZ- �' CROSS-SECTION VIEW 1 1/2" STONE RICHARD F. ZEOLI, TRUSTEE ASSESSORS MAP 51 PARCEL 99 30 1/2' PRECAST DIST. BOX T T '7 1-/2' PLAN VIEW CONCRETE I BOUND FOUND & rn HIGHPOINT ; 1 N55'16'10"E 131.07' HELD 0 IN ROAD 1 1 ^� EL. 11.4 I EXISTING WIRE FENCE `` E) NG FENCE 0 X 1 � 1 Irn D I \ . 20.1' OCT 2 z 005 y` ` ►CD 1 ! X 12 22, MDSS-SECTION OF CHAMBER DESIGN CRITERIA: DESIGN FLOW. 4 BEDROOMS AT 110 G.P.B./D 440 G.P.D. REQUIRED SEPTIC TANK: 440 X 200% = 880 GAL. SEPTIC TANK PROVIDED: = 1500 GAL. 11.6 BULKHEAD'' LOT 6 /, \����1 1Z Q ISIZE OF LEACHING FACILITY REQUIRED: 21)076± S • F 12.3 DESIGN PERC. RATE: <2 MIN./ INCH mII I I �, LONG TERM APPL. RATE 0,74 G.P.D/S.F. 00 (DO i... ...I DECK �\ / rnN I .. n 11;1: 440 GPD + 0.74 GPD/SF = 596 S.F. \\\ \ I w :N I I v! / \ EXISTING GARAGE TO 29 2' .. W I SIZE OF LEACHING FACILITY PROVIDED: I I SHED / / REMAIN USE HIGH DENSITY POLYETHYLENE 3 I /� 1 LEACHING CHAMBERS(4 UNITS) 12'X2'X35' \\ I I O 24„ I SIDEkiaLL = 2(12'+351) X 2' = 188 \ TRIPLE / \\ / EXISTING I I BOTTOM = 12' X 35' = 420 )AK /�'�\ \\ GRAVEL I I I 608S.F, DRIVEWAY 36" \ y�'\ ♦\ < / OAK O I I::: 608 S,F x 0.74 GPD/SF = 449GPD \ \ S 12.4 / I' FULL \ \ X FOUNDATION \\ \\ GAS ATE \\ 11.4' 39.9 EXISTING DWELLING/ S(E"0 M�AF S -i T.O. FND. 12.5 NGVD // fir L/ ��( PROPOSED I / / ( 1 1500 GALLON SEPTIC TANK I . C \ 11.1 X EXISTING ^\ // O / EXISTING S.A.S. \ I DWELLING TO\ // LOO J TO BE PUMPED 24'1 I / \ \ BE REMOVED \ / CRUSHED & / \ i REMOVED FROMSITE IN / \ / ACCORDANCE 11... PATIO \ / ! WITH TITLE 5 1 / PROPOSED J ........ NEW DWELLING y (PROPOSED i° i 112'05 z 11 �O ( 18" 1P.RIMARY S.A.S ! I 1 I (*1 I BEECH !! :1:1.� 1--� 1 .... w 1 ... O 0� �1 0 p�a°° 1.. i�� L J 1 - • • - I X 11.6 �, / / PROPOSED "D -BOX' • : 1 fL f Z ( . • • . ( 1 r -T ! I :::: 1 I H of k 1 P#1 ... I i I .... I:d MARK D. yGN :: �Ve �) •z 56.1' 1 1 1 1 "" 0 PROPOSED... 1 10 1 I 10.3' J No, s5s37 or 12'x35' RESERVE 'L7 X 11.3 LIMITS OF EXCAVATION U.POLE v"• SEE NOTES 5 & 6 11.1 X -MHO 16.5' " 11.6 HEDGE LINE S51.06'a W U.POLE _1. 9/26/05 ADD HIGH POINT 2 .6' - GENERAL NOTES: N CONSTRUCTION OF THE SEWAGE RI z W I D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. L4 W . 0 0 I LOCATED WITHIN 150 FT. OF THE DABNEY AMES DRAPER ANY KNOWN WELLS PROPOSED WITHIN 13.6' DEED BOOK 18841, PAGE 242 ALL TOPSOIL, SUBSOIL AND OTHER PLAN REFERENCE: PLAN BOOK 184, PAGE 131 CLEAN GRANULAR SAND, FREE FROM ORGANIC ASSESSORS MAP: 51 DEPTH PARCEL:- 98 SIEVE, SHALL BE PERFORMED ON A ZONING DISTRICT. RS -40 RETAINED ON THE #4 SIEVE. SIEVE ANALYSES SETBACKS: FRONT 30' ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SIDE 20' 100% MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) REAR 20' 4-147 • 40,000 S.F. 0%-5% MUST PASS #200 SIEVE EXISTING LOT AREA: 21,076± S.F. IN THE DRAWINGS ARE APPROXIMATE. PROP. LOT COVERAGE: 2,676± S.F. (12.77) COORDINATING THE PROPOSED CON- NITROGEN SENSITIVE AND THE APPLICABLE UTILITY CONCRETE I BOUND FOUND & rn HIGHPOINT ; 1 N55'16'10"E 131.07' HELD 0 IN ROAD 1 1 ^� EL. 11.4 I EXISTING WIRE FENCE `` E) NG FENCE 0 X 1 � 1 Irn D I \ . 20.1' OCT 2 z 005 y` ` ►CD 1 ! X 12 22, MDSS-SECTION OF CHAMBER DESIGN CRITERIA: DESIGN FLOW. 4 BEDROOMS AT 110 G.P.B./D 440 G.P.D. REQUIRED SEPTIC TANK: 440 X 200% = 880 GAL. SEPTIC TANK PROVIDED: = 1500 GAL. 11.6 BULKHEAD'' LOT 6 /, \����1 1Z Q ISIZE OF LEACHING FACILITY REQUIRED: 21)076± S • F 12.3 DESIGN PERC. RATE: <2 MIN./ INCH mII I I �, LONG TERM APPL. RATE 0,74 G.P.D/S.F. 00 (DO i... ...I DECK �\ / rnN I .. n 11;1: 440 GPD + 0.74 GPD/SF = 596 S.F. \\\ \ I w :N I I v! / \ EXISTING GARAGE TO 29 2' .. W I SIZE OF LEACHING FACILITY PROVIDED: I I SHED / / REMAIN USE HIGH DENSITY POLYETHYLENE 3 I /� 1 LEACHING CHAMBERS(4 UNITS) 12'X2'X35' \\ I I O 24„ I SIDEkiaLL = 2(12'+351) X 2' = 188 \ TRIPLE / \\ / EXISTING I I BOTTOM = 12' X 35' = 420 )AK /�'�\ \\ GRAVEL I I I 608S.F, DRIVEWAY 36" \ y�'\ ♦\ < / OAK O I I::: 608 S,F x 0.74 GPD/SF = 449GPD \ \ S 12.4 / I' FULL \ \ X FOUNDATION \\ \\ GAS ATE \\ 11.4' 39.9 EXISTING DWELLING/ S(E"0 M�AF S -i T.O. FND. 12.5 NGVD // fir L/ ��( PROPOSED I / / ( 1 1500 GALLON SEPTIC TANK I . C \ 11.1 X EXISTING ^\ // O / EXISTING S.A.S. \ I DWELLING TO\ // LOO J TO BE PUMPED 24'1 I / \ \ BE REMOVED \ / CRUSHED & / \ i REMOVED FROMSITE IN / \ / ACCORDANCE 11... PATIO \ / ! WITH TITLE 5 1 / PROPOSED J ........ NEW DWELLING y (PROPOSED i° i 112'05 z 11 �O ( 18" 1P.RIMARY S.A.S ! I 1 I (*1 I BEECH !! :1:1.� 1--� 1 .... w 1 ... O 0� �1 0 p�a°° 1.. i�� L J 1 - • • - I X 11.6 �, / / PROPOSED "D -BOX' • : 1 fL f Z ( . • • . ( 1 r -T ! I :::: 1 I H of k 1 P#1 ... I i I .... I:d MARK D. yGN :: �Ve �) •z 56.1' 1 1 1 1 "" 0 PROPOSED... 1 10 1 I 10.3' J No, s5s37 or 12'x35' RESERVE 'L7 X 11.3 LIMITS OF EXCAVATION U.POLE v"• SEE NOTES 5 & 6 11.1 X -MHO 16.5' " 11.6 HEDGE LINE S51.06'a W U.POLE rn 0 0 0 X 11.3 �9C 15" -PINE 15"PINE MHO -----'-MHO -MHO 137.60' - .- ��-•� .ft - �i.;•i�L�.� � R 'fir' PLAN JOAN ASSESSORSF. SLABINE SCALE: 1' 10 FEET PARCEL 97 F 9.7 F 1 5 10 20 LOCUS INFORMATION U.POLE _1. 9/26/05 ADD HIGH POINT 2 .6' - GENERAL NOTES: N CONSTRUCTION OF THE SEWAGE RI z W I D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. L4 W . 0 0 I LOCATED WITHIN 150 FT. OF THE DABNEY AMES DRAPER ANY KNOWN WELLS PROPOSED WITHIN 13.6' U.POLE rn 0 0 0 X 11.3 �9C 15" -PINE 15"PINE MHO -----'-MHO -MHO 137.60' - .- ��-•� .ft - �i.;•i�L�.� � R 'fir' PLAN JOAN ASSESSORSF. SLABINE SCALE: 1' 10 FEET PARCEL 97 F 9.7 F 1 5 10 20 LOCUS INFORMATION NO. DATE DESCRIPTION _1. 9/26/05 ADD HIGH POINT _2._. 10/20/05 RELOC. TANK GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT CURRENT OWNER: ROY WILSCHUT & 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE DABNEY AMES DRAPER ANY KNOWN WELLS PROPOSED WITHIN TITLE REFERENCE: DEED BOOK 18841, PAGE 242 ALL TOPSOIL, SUBSOIL AND OTHER PLAN REFERENCE: PLAN BOOK 184, PAGE 131 CLEAN GRANULAR SAND, FREE FROM ORGANIC ASSESSORS MAP: 51 OF SOIL SHALL NOT BE USED. THE FILL SHALL PARCEL:- 98 SIEVE, SHALL BE PERFORMED ON A ZONING DISTRICT. RS -40 RETAINED ON THE #4 SIEVE. SIEVE ANALYSES SETBACKS: FRONT 30' ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SIDE 20' 100% MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) REAR 20' (0.30 mm EFFECTIVE PARTICLE SIZE) MINIMUM LOT SIZE: 40,000 S.F. 0%-5% MUST PASS #200 SIEVE EXISTING LOT AREA: 21,076± S.F. IN THE DRAWINGS ARE APPROXIMATE. PROP. LOT COVERAGE: 2,676± S.F. (12.77) COORDINATING THE PROPOSED CON- NITROGEN SENSITIVE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE ZONE: NOT A ZONE II THE STATE OF MASSACHUSETTS FEMA FLOOD AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE ZONE DISTRICT: ZONE "B" & "A-11" ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES #250015 0004 C, CONTRACTOR SHALL VERIFY SIZE. LOCATION AND INVERTS OF UTILITIES DATED 6/17/86 TO 74.r-- -" •T OF CONSTR'JCTIU'.. OVERLAY DISTRICT. ADVISORY HISTORIC COMMISSION THE USE OF A GARBAGE GRINDER. N28 �zv/O j o m 3 10.4 �� �co/) 10.5 �t REVISIONS NO. DATE DESCRIPTION _1. 9/26/05 ADD HIGH POINT _2._. 10/20/05 RELOC. TANK GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE ALL EXCAVATED MATERIAL WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN TWO INCHES. A SIEVE ANALYSIS, USING A #4 SIEVE, SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL. UP TO 45% BY WEIGHT OF THE FILL SAMPLE MAY BE RETAINED ON THE #4 SIEVE. SIEVE ANALYSES ALSO SHALL BE PERFORMED ON THE FRACTION OF FILL SAMPLE PASSING THE #4 SIEVE, SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS #4 SIEVE (4.75 mm EFFECTIVE PARTICLE SIZE) 10%-100% MUST PASS #50 SIEVE (0.30 mm EFFECTIVE PARTICLE SIZE) 0%-20% MUST PASS #100 SIEVE (0.15 mm EFFECTIVE PARTICLE SIZE) 0%-5% MUST PASS #200 SIEVE (0.075 mm EFFECTIVE PARTICLE SIZE) 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE. LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO 74.r-- -" •T OF CONSTR'JCTIU'.. B. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. GI 6.1,1 1`'lalin Suer";, (RT. 28) fU>nu�t 6 Ui t"aTvnauth- 0267 s 50ffi 7`18 83'lig PROJECT TITLE: DESIGN FOR SEWAGE DISPOSAL SYSTEM 17 AUNT EDITH'S ROAD So. H ,�Y^/IAS V� PREPARED FOR: NORTHERN HERITAGE BUILDERS Mr. ROBERT MOORE 32 WIANNO AVENUE OSTER VI LLE MA 02655 (508) 428-1666 DATE: SEPTEMBER 9, 2005 COMP. DESIGN: K. HEALY CHECK: M. DIBB DRAWN: K. HEALY FIELD: D. GAZZOLO / J. McCARTIN FILE N0. 8796SEP1.DWG DWG NO. 5603-02 SHEET 1 OF 1 JOB NO. 4-8796.01