Loading...
HomeMy WebLinkAbout93 Avon Road - Septic Design 3TOP OF FOUNDATION 20 FL M'NIMUM FROM CELLAR „_r O - � ELEV. _ 10270 10 FT. MINIMUM 10 F7. M:NiMUM FROM SLAB OR CRAWL SPACE • etvarw �ozm' \ r -- CLEAN SANG ��N / rasa �J CONCRETE ,�- - OA COVERS - INSPECTON PORT / 4" SCHEDULE 40 PVC PIPE LOAM AND SEED 000 MIN. PITCH 1/8" PER T. 2 LAYER OF -"�•� _ �,� / -1 /8 _ TO 1 /2" 1I - 6$,47' _ 4": CAST IRON PIPE Ax A 90.00 MAX. WASHED STONE.:VENT... - / 1 c AB ELEV. = 95.20 67.75 k. N. NOT REQUIRED _L - (OR EQUAL) MINIMUM l •� - PITCH 1/4" PER FT. 1 / - TEE / FLOW UNE / tg2i 87.00 ' a LOT 24 o / ELEV. = e22o —Te, N. LEY. - 89.00 ' 2 0 0 ° t k,� . o LEVEL e : l t ` 10 C5 67 AREA 13, 3391 S F. ELEV..2s_ OAS s7 Js' SUMP l'' 1 �I £LEV. _ �^ '/ - ELEV. _.._.- ELEV = $7_00 k BAFFLE DISTRIBUTION ELEV.= •\ UOVID -0UTLET y 4 HIGH CAPACITY INFILTRATORS WITH °"`- ' .i5.'>_ STONE IN AN „ -DEPTH (TO BE PLACED ON FIRM BASE) - SOA - 17 I - 4 FEET 14 IN-H_S TO -BE WATER TESTED jj, J c 5 FEET : 19 INCHES 1F MORE THAN ONE OUTLET 11' X 33* X 10 TRENCH FORMATION p 6 FEET 24 INCHES 1500 GALLON �. 7 FEET 29 INCHES T1 T _ (TO BE PLACED ON FIRM BASE) SO!L ABSORPTION 'n WELL - NA �/ `TX6T ^ \ •� B FEET 34: INCHES SEPTIC. TANK 3/4•.T0.1 1/2" CLEAN T� [�- c+ : ZONE :DOUBLE WASHED STONE SYSTEM (SAS) ;INDEX o FREE OF FINES d SILT ADJUST o DISPOSAL I A •, nr� ry 9 O .. .ate - : SEWAGE DISPOSAL' SYSTEM PROFILE . USGS PROBABLE WATER TABLE ELEV. _ `i NOT TO SCALE OBSERVED WATER. TABLE ( / � % ) ELEV. _ PROP BOTTOM OF TEST HOLE ELEV. - Ii? a eEO°RQo"Mwnrc °� SOIL TEST DESIGN CALCULATIONS S DATE OF SOIL TEST A�u�S12Z X041-_ NUMBER OF BEDROOMS 3� SOIL TEST DONE BY SYY_EISEP,_EN2lN=EPLNG GARBAGE DISPOSAL UNIT 0_ WITNESSED BY _LJ!QLK.EF_NL. TOTAL ESTIMATED FLOW h \ WALKO 5.4 a� v�iiO"a H4! E i ELEV:- 89.50 ( 110 GAL./BR./DAY X .3_ BR.) _.3,'0_ GAL./DAY y UT - - REQUIRED SEPTIC TANK CAPACITY GAL. a �N - -- / PERCOLATION RATE <�__ MIN./INCH AT X66 INCHES ACTUAL SIZE OF SEPTIC TANK 1f�OU GAL DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-9 0/A. LOAMY SAND 10YR2/1 NO ROOTS 9-54 B LOAMY SAND 10YR6/6 MtOa GAL./DAY ROOTS 54-120 C MEDIUM SAND 10YR7/6 s l.M GAL./DAY SOIL CLASSIFICATION --I— TEXTURE DESIGN PERCOLATION RATE 5_5_ MIN./1N. OTHER EFFLUENT LOADING RATE --01-4- GAL./DAY/S.F. LOAMY SAND LEACHING AREA 474.33 SQ. FT. ROOTS (11X38)t(47X2X10/12) B LOAMY SAND LEACHING CAPACITY (AREA X RATE) MtOa GAL./DAY ROOTS__ 474.33 X 0.74 C MEDIUM SAND RESERVE LEACHING CAPACITY s l.M GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P.:' - TITLE 5 AND THE TOWN OF ___Yi6VWT�L — RULES AND .. - LOCATION MAP REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. SHEET 1 07 1 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6 O FINISHED GRADE. 3 ALL COfdPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF ,.171CTAND;NG H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 5.Q- 1 00 WATER ENCOUNTERED AT -190" ELEV. _ _Z3.0 FT. OF DRIVES OR` PARKING AREAS.. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. \�9t.4• ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL I` - ELEV,=00 BE MORTARED PLACE. 1 /�Go \ OD? �If1jQy� f{� PERCOLATION RATE _<�2�_ M',N./INCH IN C HORIZON 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE W.TH : DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-10 0/A LOAMY SAND 16YR2/1 NO ROOTS 10736 B LOAMY SAND 10YR6/6 ROOTS__ 36-120 C MEDIUM SAND 10YR7/6 REV. DEC. '12,, 2002 DEEDED OR ZONING REGULATIONS. OWN ER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION ' IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE C 9. LOT IS SHOWN ON 'ASSESSORS MAP _ 134_ AS PARCEL 10.:ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR A MIN!MJM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH SAND AS SPECIFIED IN 310 CMR 15.255:(3). APPR0\Irr)o BOARD : OF w17 1 TH -. NO WATER ENCOUNTERED AT -120__ ELEV. io C:) DATE AGENT — h ! Ii OF ,/ i firt, / _� A• -Iso j wt LEGEND: EXISTING SPOT ELEVATION 00.0 c EXISTING CONTOUR ---00---- �` FINAL SPOT ELEVATION 0 . FINAL CONTOUR SOIL TEST LOCATION < UTILITY POLE -O �l TOV,N WATER —WSW 96.43 ' L Q I CATCH BASIN LA GAS LINE TFOR�E CLEAN OUT C III CESSPOOL C.P. o .9 0 LOCUS A STRAD7D 2 RpU�. 6• q PROPOSED SEPTIC DESIGN FOR DUDIa!s CUTSTRUC'Ilo l PROJECT LOCATIO SOTS 23 & 24 g -AVON ROAD, YARM.OUTH 235 GREAT WESTERN ROAD 508- P. 0. 'BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE NOV. 5, , 2002 FCALE 1 " 20' REV. DEC. '12,, 2002 JOB No. 5500- 2r LOCATION MAP REV., DEC. ,31; 2002 SHEET 1 07 1