Loading...
HomeMy WebLinkAbout12 Barkentine Circle - Sewage Disposal Plan 2SOIL TEST PIT DATA: 11/22/99 SEPTIC TANK DETAIL: 1,500 GALLON DISTRIBUTION BOX DETAIL: NOT TO SCALE SOIL ABSORPTION SYSTEM: NOT TO SCALE NOT TO SCALE NO. OF OUTLETS 1 37.5' t TEST PIT #Z- TEST PIT #8 NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON, FINISHED GRADE 00 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 7 GRD EL 4 2 REINFORCED CONCRETE SCHEO. 40 PVC OR CAST -IN-PLACE CONCRETE o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 GRD. EL. GW. EL. 2.5' ADJ. , GW. EL. 2.5' ADJ 2. SEPTIC TANK TO WITHSTAND H-10 LOADING TEES TO BE CENTERED UNDER MANHOLE COVER. PAVEMENT, REMOVABLE ��- COVER I V WALLS NOTES: 0 0 UNLESS UNDER DRIVES OR 1 TEST r (� „ LOAMY SAND 1OYR 2/1 „ LOAMY SAND 10YR 2/1 4 7 TRAVELED WAYS, WHEREIN H-20 LOADING �: •9..+.�: •�..+,a::v.... (:.ti.::.' PARCELS: 1. DIST. BOX TO WITHSTAND H-10 LOADING ' E 1 8" LOAMY SAND 2.5YR 5/1 1 LOAMY SAND 2.5YR 5/1 B E 19„ SHALL APPLY. 3. ALL PIPE CONNECTIONS AND CONCRETE 2" T PVC B"�°°I UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS WHEREIN H-20 LOADING 0 THE BSC GROUP, INC. PERC. - WITNESSED BY- 0 PLAN REFERENCE: TEST r (� AMY VON HONE / KELDA WELSH AMY VON HONE / 0 PARCELS: 39, 40, 41.1, 45.1 5 UNITS "R-25" SETBACKS: 4" PVC oo PIPE ° PERC. RATE: PERC. RATE: REAR 15' O THE YARMOUTH CONSERVATION COMMISSION AT A MEETING ON DECEMBER 2, 1999. 0 0 0 °° 50' 10' 19" LOAMY SAND IOYR 5 6 - " LOAMY SAND 10YR 5 6 CONSTRUCTION SHALL BE WATERTIGHT. o / B / 2-24 DIA CONCRETE MANHOLE °°00 0 0 00 °° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 ' TO 6E" FROM FINISH AL HADELES BROUGHT � '� a�' 15• SHALL APPLY. 2' fL = 2.1 2 24 0 00 0 0 0 00 0 000 00 0 00 0 EL 1.5 4. FILL ALL UNUSED KNOCKOUTS WITH ' C1 3' C 33 MORTAR. B• J 2. PROVIDE INLET TEE OR BAFFLE WHERE { 40' 31- j 6" 5,5" OUTLETS -SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR42" _42" TEE TO BE UNDER f'y :•a.... � •. • PLAN VIEW - LEACHING CHAMBERS 4 4 M.H. OPENING 12" MIN• 3' pQ ". " o e0�eea j IN PUMPED SYSTEM. MED SAND 10YR 6/6 MED SAND 10YR E/6 COVER L. 2" 3. FIRST TWO FEET OF PIPE OUT OF DIST. 5 5 to' -6" RAISE WCL► ¢" BOTTOM ON LEVEL 6• MIN. 3/4" TO BOX TO BE LAID LEVEL LOAM & SEED DISTURBED AREAS BR SEWER BRICK �, - • STABLE BASE 1 1/2" CRUSHED 61- C 6 C 10'-0" &MORTAR a CROSS-SECTION 4. ALL PIPE CONNECTIONS AND CONCRETE 2 2 NORMAL WATER LEVEL 12" STONE BASE CONSTRUCTION SHALL BE WATERTIGHT. 3' MAX. COMPACTED FILL 36" MAXIMUM 12"MINIMUM 7' 82" 7' MED SAND tOYR 6/2 � 10. 3" 14' o 0 0 o poo° o°o 000 0°0 3" LAYER 7 PRECAST SEPTIC TANK e I 8' 8' a INLET TEE :1 ¢'_g• g' MED SAND 10YR 6/2 9' O C 5'-2" 4'-6" e e 5._¢" _ 4'-0" MIN. � � 15 1/2" INDICATES 10 10 120" �_ OBSERVED Z "LIQUID DEPTH 5'-8" 125" EL = (-5.8) - GROUND WATER N '. 11,_ EL = (-6.7) b -F.: �.i.:::: a$•••:•: :-.-•i-:�:; .!�:�B::e 12° 12 INDICATES �- ESTIMATED c BOTTOM ON LEVEL STABLE BASE a 3• SEASONAL HIGH PLAN VIEW �,����day DATE: DATE: GROUND WATER 6" MIN. 3/4" TO CROSS-SECTION VIEW 11/22/1999 11/22/1999 1 1/2" STONE TEST BY: TEST BY: INDICATES THE BSC GROUP, INC. THE BSC GROUP, INC. PERC. - WITNESSED BY- WITNESSED BY: PLAN REFERENCE: TEST r (� AMY VON HONE / KELDA WELSH AMY VON HONE / KELDA WELSH PARCELS: 39, 40, 41.1, 45.1 NOTES: "R-25" SETBACKS: FRONT 30' TP 10 #' PERC. RATE: PERC. RATE: REAR 15' O THE YARMOUTH CONSERVATION COMMISSION AT A MEETING ON DECEMBER 2, 1999. _LLMIN./INCH -2-MIN./INCH 2.) THE LOT SHOWN HEREON WAS CREATED VIA AN APPROVAL NOT REWIRED, (ANR) PLAN BY THE BSC GROUP, INC. 10!" (MAX) BY WT. SHALL OVERLAY DISTRICT: SIGNED BY THE PLANNING BOARD ON MARCH 1, 2000. PASS No. 100 v INDICATES UNIFORMITY COEFFICIENT O No. 4 SOIL EVALUATOR SOIL EVALUATOR IN THE DRAWINGS ARE APPROXIMATE. UNSUITABLE 5.) ADJACENT SITE FILLING IS UNDERSTOOD TO OCCUR PRIOR TO TRANSFER OF TITLE, THEREFORE NO FILL EASEMENTS MICHAEL PETRIN MICHAEL PETRIN ARE REQUIRED. MATERIAL --- 6.) BEFORE THE LOT IS FILLED THE AREA OF THE SEPTIC AND RESERVE IS TO BE EXCAVATED AND INSPECTED BY THE THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 BOARD OF HEALTH AND THE BSC GROUP, INC., THEN BACKFILLED WITH MATERIALS NOTED IN GENERAL NOTES 5 & 6. ENGINEER DOES NOT GUARANTEE SOIL CLASS: SOIL CLASS: NOTE: ELEVATIONS OF UNDERGROUND UTILITIES YARMOUTH CONSERVATION COMMISSION ON AUGUST 3, 2000. 1 1 DUE TO THE PROXIMITY TO --,- - '- TO BE DETERMINED BASED ON ACTUAL HOUSE DIMENSIONS. A GARBAGE GRINDER IS NOT TIDAL INFLUENCE , HIGH ADVERSE IMPACT'S TO THE LEACHING L.T.A.R. L.T.A.R. GROUND WATER ADJUSTMENT 0.74 G.P.D./SQ.FT. 0.74 G.P.D./SQ.FT. TO BE SET AT 2.5' N.G.V.D. --------- ---'-8 -- _-___-_ g DATUM: 657 ROUTE 28, (UNIT 6) WEST YARMOUTH, MA 02673 (508) 778-8919 VERTICAL DATUM: N.G.V.D. SEWAGE DISPOSAL SYSTEM DESIGN LOT 5 BENCHMARK ARKENTINE CIRCLE S. YARMOUTH TOP OF CONCRETE BENCH MARK USED: TOWN OF YARMOUTH, MON. #8 6.29' N.G.V.D. BOUND, ELEVATION BENCH MARK SET: TOP OF CONCRETE BOUND, ELEV. 5.92' 1645 FALMOUTH ROAD, UNIT C = 5.92' N.G.V.D. -- PROFILE: NOT TO SCALE DATE: JULY 12, 2000 COMP./DESIGN: K. HEALY CHECK: D. CRISPIN DRAWN: K. HEALY FLOOD ZONE EL= A Tipp FOUNDATION COVERS TO WITHIN FIRST PIPE LENGTH DWG NO. 5179-10 Al2. ELEV 10' 6" OF FINISHED GRAD =11.9' TO BE SET FOR MIN. � LEVEL 2' FINISH GRADE 15' MIN SEE � 5 &t6 �' 301/2- PRECAST /1 2" PRECAST DIST. BOX T T ` , V LIMIT OF ` EXCAVATIONS '~^- SEE NOTES w80.7� 19.0' �D Qr N8075'4]"W "�►..' _ �.,..,l11 a �_7La 1 � 17 DRYWELL FOR 0 ! ROOF RUNOFF 1 LIMIT 0F�1,500 g ��Aasn. EXCAVATION GAL 2I ®� SE -t NOTES SEPTILMtN> r '5 & 6 TANK 7 1/2" PLAN MEW 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. Qp HIGH O 00 0 PEASTONE 301, 00 DENSITY 0 0 0 REMOVE O pQ POLYETHYLENE 0 p UNSUITABLE EFFEC. Cb0 0 INFILTRATOR 3050 p0 0 0 MATERIAL FOR DEPTH G� LEACHING 0 O 5' ALL AROUND 1 2j 0 0 CHAMBER p IF APPLICABLE i 35" 50" 35" MASHED 1STOtNE I LI I - 20' OLD SALEM CROSS-SECTION OF CHAMBER DESIGN CRITERIA: DESIGN FLOW: J -'4j 4 BEDROOMS AT110G.P.B./D 440 G.P.D. REQUIRED SEPTIC TANK: 440 X 200% = 880 GAL. SEPTIC TANK PROVIDED: = 1500 GAL. CTI /' ! 6" SIZE OF LEACHING FACILITY REQUIRED: ♦�Iz/ DESIGN PERC. RATE: <2 MIN./ INCH 1'1'117952' LONG TERM ACCEPT. RATE 0.74 � G.P.D/S.F. 8 N0 „x,.5'41"Vy 40 r 1pn_13 so PROPOSED ` Q� 1110 4 BEDROOM `.�Is� ��-... l /.. DWELLING '� �►''! ���®'� SIZE OF LEACHING FACILITY PROVIDED: .,, ,% TOGARAGE `T.0 F 13.1 .40%,`E I'�` Y 12.3 t �p �r R `I f - Il�tl�ll �Il+�llell ml►stl'It i{''alb 1, •. .-.- -., / 1nn. 1r •' ,74 5 S,F, 0 Z . ��`�a_____________b i,- USE HIGH DENSITY PO!-YETHYLENE LEACHING CHAMBER V ,, , r SCH 40 MAX � cn � :� ( Ir+, ..J1%.i � f 1 � �-.� 1C:fl_11 ; LEACHING CHAMBERS 10 X2 X40 =C I -E DIST. BOX H ----------- FL-0OD�ONE I=F DRYWELL FOR P , / r ::.:;;:; ! ,I`C'�+4w„(•r'�� Al2. V 10'� 1C'1-10 5' SEPERATION ROOF AND : i / ,e ] / `r 1 /' z 1500 GALLON SEPTIC TANK I SURFACE RUNOFF. / `.' `, • . ,�% 'f ( 1 o 6" STONE BASE t ADJUSTED GROUNDWATER s T 1 lttn-R ICJ -9 1�!, O. INVERT ELEVATIONS: tl_It_11_11_tom litwlg t .►E.:yF �5 �P100-B 100-6..i TOP OF FOUNDATION 13.1' A r`� 6 wI FEt�♦� OE 01� 4" INVERT AT BUILDING 10.27' BI�ROPOSED LANDSCAPE W �1PROPOSED,SILT TIMBER CURBING - INSTALU0-5 4 INVERT AT SEPTIC TANK (IN) 10.07 C �"3 } ; ,-' ` TOP OF TIMBER 6" ABOVE 4" INVERT AT SEPTIC TANK (OUT) 9.82' D �tY �' $ ,�� r` '4 V- DRIVEWAY GRADE _I1� ✓ 4" INVERT AT DIST. BOX (IN) 9.72' E rr�� o� j I i ]�i� �" LOT 5 V t (0 100-z4 "`GGG .. 4" INVERT AT DIST- BOX (OUT) 9.55' F i ro ; cr ;f i/ 18,108± S.F. WETLAND W 28.4091 S.F. UPLAND T l ,, t #2 / 46,517± S.F. TOTAL AREA V INVERTS AT LEACHING FACILITY: V 4 � P10-NJPd r �"' : 100-3 � 4 INVERT AT BEGINNING �. �j 1r. OF LEACHING CHAMBER 9.5 G""" / f\tsl, 211.28' r P I r f #yam? ELEVATION AT BOTTOM 7.5' H ' \ ,' ,.�3 0� M.,_ / .OF LEACHING CHAMBER-15'41 at S80.1541.� e #4 f / E ADJUSTED CURRENT OWNER: THOMAS RUHAN GROUNDWATER 2.5' J BOOK 10,389, PAGE 024 5 Z m < < N c VARIANCES REQUESTED: PLAN REFERENCE: BOOK 181, PAGE 125 ;0D ;U BOOK 489, PAGE 27 ASSESSORS MAP: NONE PARCELS: 39, 40, 41.1, 45.1 NOTES: "R-25" SETBACKS: FRONT 30' ANY KNOWN WELLS PROPOSED WITHIN SIDE 15' 1.) EDGE OF BORDERING VEGETATIVE WETLANDS (BVW) DELINEATED BY NORMAN W. HAYES , PWS AND APPROVED BY REAR 15' O THE YARMOUTH CONSERVATION COMMISSION AT A MEETING ON DECEMBER 2, 1999. MINIMUM FRONTAGE: p vi 2.) THE LOT SHOWN HEREON WAS CREATED VIA AN APPROVAL NOT REWIRED, (ANR) PLAN BY THE BSC GROUP, INC. 10!" (MAX) BY WT. SHALL OVERLAY DISTRICT: SIGNED BY THE PLANNING BOARD ON MARCH 1, 2000. PASS No. 100 v 3.) THE ENTIRE LOT FALLS WITHIN THE FLOOD ZONE Al2, ELEVATION 10.00' N.G.V.D. UNIFORMITY COEFFICIENT O No. 4 SIEVE </=6.0 4.) THE HOUSE IS SUBJECT TO FINAL ARCHITECTURAL DEIGN AND THE FOOTPRINT MAY VARY. IN THE DRAWINGS ARE APPROXIMATE. THECONTRACTOR SHALL BE RESPON- 5.) ADJACENT SITE FILLING IS UNDERSTOOD TO OCCUR PRIOR TO TRANSFER OF TITLE, THEREFORE NO FILL EASEMENTS COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE ARE REQUIRED. COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. 6.) BEFORE THE LOT IS FILLED THE AREA OF THE SEPTIC AND RESERVE IS TO BE EXCAVATED AND INSPECTED BY THE THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 BOARD OF HEALTH AND THE BSC GROUP, INC., THEN BACKFILLED WITH MATERIALS NOTED IN GENERAL NOTES 5 & 6. ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL 7.) SITE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE ORDER OF CONDITIONS ISSUED FOR LOT 5 BY THE ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES YARMOUTH CONSERVATION COMMISSION ON AUGUST 3, 2000. CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES 8.) DRYWELL LOCATIONS SHOWN ON THIS PLAN ARE APPROXIMATE. SIZE AND ELEVATION OF EACH DRYWELL TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR TO BE DETERMINED BASED ON ACTUAL HOUSE DIMENSIONS. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED SCALE:1 FE 0 10 20 40 ? OO -2 Nti O W - N'-__ 100-1 CO CO 0 M O� 56� OF 3 GA I6a 3808 d ' ft SIDEWALL = 2(10'+40') X 2 = 200 BOTTOM = 10' X 40' = 400 600 S.F. 600 S,F x 0,74 GPD/SF = 444 GPD LOCUS INFORMATION CURRENT OWNER: THOMAS RUHAN DEED REFERENCE: BOOK 10,389, PAGE 024 5 Z m < < N c BOOK 12,466, PAGE 014 PLAN REFERENCE: BOOK 181, PAGE 125 ;0D ;U BOOK 489, PAGE 27 ASSESSORS MAP: 19 PARCELS: 39, 40, 41.1, 45.1 RESIDENTIAL ZONE: "R-25" SETBACKS: FRONT 30' ANY KNOWN WELLS PROPOSED WITHIN SIDE 15' 5. WITHIN LIMIT OF EXCAVATION REMOVE REAR 15' MINIMUM LOT SIZE: 25,000 S.F. MINIMUM FRONTAGE: 150' GROUNDWATER 10!" (MAX) BY WT. SHALL OVERLAY DISTRICT: NONE LOCUS PLAN: NO SCALE 28 t 0 to 0 RI D D D m D � 5 Z m < < N c vii z z m m ;0D ;U C.;" LOCUS ORE 0_ - 8Ei, PARKERS RIVER BEACH NANTUCKET SOUND REVIS(,008" ,t t NO. DATE DESCRIPTION 1. 8/16/00 B.O.H. ISSUE 2. 12/11/00 B.O.H. COMMENTS GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS, 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL 4, THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE All TOPSOIL SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE WITH CLEAN WASHED SAND OR OTHER CLEAN GRANULAR SOILS CONFORMING TO THE FOLLOWING SIEVE ANALYSIS: 10!" (MAX) BY WT. SHALL PASS No. 50 SIEVE <10 R OF No. 4 SIEVE SHALL PASS No. 100 <5 X OF No. 4 SIEVE SHALL PASS No. 200 UNIFORMITY COEFFICIENT O No. 4 SIEVE </=6.0 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THECONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE U71UTY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REWIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACT'S TO THE LEACHING FACILITY. LJI ` The BSC Group, Inc r 657 ROUTE 28, (UNIT 6) WEST YARMOUTH, MA 02673 (508) 778-8919 PROJECT TITLE: SEWAGE DISPOSAL SYSTEM DESIGN LOT 5 #12 ARKENTINE CIRCLE S. YARMOUTH 1 4 ss> LISA A S iMACDONALD N o CIVIL y % 0 PR PARED FOR: BOSWORTH ASSOCIATES P.O. BOX 685 1645 FALMOUTH ROAD, UNIT C CENTERVILLE, MA 02632 DATE: JULY 12, 2000 COMP./DESIGN: K. HEALY CHECK: D. CRISPIN DRAWN: K. HEALY FIELD: P.H. / A.D. FILE NO. 8188-SEP.DWG DWG NO. 5179-10 SHEET 1 of 1 JOB NO. 4-8188.00