Loading...
HomeMy WebLinkAboutEngineered Plans - 2015r — 98 — —EXISTING CONTOUR R � --'Ponld BH x 100.98 EXISTING SPOT GRADE Rte 28 n BENCHMARK BATH —W—EXISTING WATER SERVICE MO'n o OUTS/DE COR./8OTT. STEP G EXISTING GAS SERVICE EL.=97.35 BED RM. BED RM. EXISTING CESSPOOLS KITCHEN 3 TO BE PUMPED, FILLED WI TN OVERHEAD WIRES o SAND & ABANDON TEST PIT Li► BENCHMARK m tiN LIVI. ROOM BED RM. Q o x 96'28 x PROPOSED SEPTIC TANK LEGEND' v m o3 r 3 95,03- p 6� B �? U N 10°33'30" W 98 FLOOR PLAN p(' 89 Clev and wa vi +6,57 16 71' 99 LOCUS 10 ^' �? 100.60 95.36 \ 9 I 9 ; 6 ^ ` X `SlfED �` 98,83 , Q x 99.26 gg TP /.;':<.;� LOCUS MAP 97,09 / RSP NOT TO SCALE I \ 97,16 x 9791 x` �! : sq •�� IT GENERAL NOTES: i :9$,,., I �rCo 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL i t %,I•:. :' ^ .. nl BOARD OF HEALTH AND THE DESIGN ENGINEER. II ( 97,27 973 97,89 iv OF i 2. ALL WORK AND MATERIALS SHALL CONFORM CO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE x I I ShBH VLNT� LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: 310 CMR 15.405 1(b) : CONTENTS OF LOCAL UPGRADE APPROVAL 1) a 2' varaiance to maximum cover requirement for 5' of cover. INV, =95 Dt/ \ c� —` •n/ ¢ 3 ESEWAGE INS INSPECTION DISPOSAL AND APPROVAL BACKFILLED SHALL NOT BE BY THE B ARD OF TOHEALTH AND THE DESIGN ENGINEER. Q .:.....` . I EXISTING r \ 1 10010 of 2 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING f I I 97.59 HOUSE(#95)� \ Q FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN I T O.F.=98.87E \ i LOT 68 o ENGINEER BEFORE CONSTRUCTION CONTINUES. 1,744 /00 ±SF 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 0/' I x� / 97,74\MppLB�� �0 Q 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF v 6 89\QQC` �a THE CONTRACTOR OR OWNER TO NOTIFY THE 'LOCAL BOARD OF ":-:,; :,;.; • '\ \ 8,03 HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. �.: 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. x 97,6 x > 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. \ >/ 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS x 97.86 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE \ ` DIRECTED BY THE APPROVING AUTHORITIES. CD 3 ob 99.3 '� 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 95.95 1 122.90' I �r� 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 95.57 IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND S 1524'00" E I c�0 REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 27,00 99,39 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 95,19 96,38 edge oaf pavement 97 72 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. Permit valid for REPAIR OF' SEPTIC SYSTEIN 98,87 ONLY; due to State and Local set ri n s OF M ss9 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC lth eve a d approv,11 i qu� d SYSTEM COMPONENTS NOT SHOWN ON THE PLAN y iMV, a d' is DovaIion's a (t rat oyds o PETER T. PROPOSED SEPTIC SYSTEM UPGRADE PLAN W swage farrhhes and/or structu� is/dwelling:' M ENTEE Yarmouth "callh De artment ' Jo L. e CIVIL 95 WENDWARD WAY, SOUTH YARMOUTH, MA CHU HI JR. I No, 35109 APPRON1 Ea / j .4 66 A �/51���0 Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 OWNER OF RECORD J p0� SI ��\ Engineering by: Surveying by: SCALE DRAWN JOB. NO. OrFG/ Engineering Works Inc. JC Engineering, Inc. 1 =20 P.T.M. 255-15 LEONOVICH, GEORGE A , ; ' 12 West Crossfield Road 2854 Cranberry Hwy. 95 WENDWARD WAY j/ Forestdale, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO. 'a' SOUTH ve`r, MA 026 a ` Date l (508) 477-5313 (508) 273-0377 1/15/16 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, FINAL GRADE SEPTIC TANK SHALL NOT BE AT, OR BELOW, EL.=94.5 INSTALL RISERS & COVERS OVER INLET & FOR A DISTANCE OF 15' FROM THE EDGE OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED D -BOX OF THE PROPOSED S.A.S. SHED INSTALL RISER & COVER SET TO 6" OF GRADE T.O.F=98.87± PROPOSED S.A.S. INSTALL RISER & COVER OVER EACH CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSP TIQN PORT F.G. EL.=97.81 F.G. EL=97.3± F.G. EL.=98.31 F.G. EL.=98.5 to VENT ! iN / %p99.5± S'4 a MAINTAIN 2% SLOPE OVER S.A.S. S 6g' ��/N L = 12' 3'(max.) L = 33' -- ®S=1% (MIN.) ®S=1% (MIN.) ®S 1%5(MIN.) 4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC 2" LAYER OF 1/8" TO 1/2" shr SH 40 " DOUBLE WASHED STONE , e• ®®®�®®® (OR APPROVED FILTER FABRIC) / EXIST SEWER a" INV.=94.80 48��IU10 0000000 ®0000®®-3/4' W SHED STONEUBLE V. ADDINV.=94.22 PRS OX � INV.=94.05 4' 5.2' - '4' EFFECTIVE WIDTH = 12.8 iHOUSE(#95)1 INV.=94.55 " 3 OUTLETS INV.=94.00 TO. .=98.87± PROPOSED SEPTIC TANK 2-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN CONNECT TO EXISTING SUITABLE SEWER PIPE/S AT HOUSE, AT OR ABOVE, INV.=95.0±(verify) H-20 RATED TOP CONIC. ELEV.= 95.1± BREAKOUT ELEV.= 94.500000 SEPTIC LAYOUT NOTES: INV. ELEV.= 94.00 00000 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & INVERTS EXITING HOUSE, PRIOR TO INSTALLATION, BOTTOM ELEV.= 92.00 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND4' TRUE TO GRADE ON A MECHANICALLY COMPACTED 4' OF NATURALLY OCCURRING 2 x 8.5' = 17.0' 4' EFFECTIVE LENGTH = 25.0' SIX INCH CRUSHED STONE BASE, AS SPECIFIED PERVIOUS MATERIAL 5 (MIN.) ABOVE G.W. IN 310 CMR 15.221(2). LEACHING SYSTEM SECTION ® ® ® ® O 3) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTTOM OF TEST PIT, EL.=86.5 r ® ® ® ® ® ® ® ® ® ® ® 37 „ 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE ® E3 E2 E3 Ea E3 E2 Ea E3 E3 Ea AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. N Z ®L3 -ED ®®®®® SEPTIC SYSTEM PROFILE 102" DESIGN CRITERIA SOIL LOG 4" KNOCKOUT NUMBER OF BEDROOMS: 3 BEDROOMS DATE: DECEMBER 23, 2015 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) 20" DIA. COVER SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) WITNESS: AMY VON HONE R.S. HEALTH AGENT DESIGN PERCOLATION RATE: <2 MIN/IN ELEV. TP -1 DEPTH 4" KNOCKOUT 4" KNOCKOUT 58" 0 DAILY FLOW: 330 GPD 98.5 A 011 DESIGN FLOW: 330 GPD LOAMY SAND 10YR 4/2 4" KNOCKOUT GARBAGE GRINDER: NO -not allowed with design 97.5 e 12„ LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF LOAMY SAND 10YR 5/8 500 GALLON CAPACITY, H-20 LOADING .74 GPD/SF 95.8 32" C CHAMBERS PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY PERC PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED 32"/50" N.T.S. USE 2-500 GALLON LEACHING CHAMBERS IN SERIES M -C SAND PROPOSED SEPTIC SYSTEM UPGRADE PLAN SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES 2.5Y 6/6 95 WENDWARD WAY, SOUTH YARMOUTH, MA SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. Prepared for: D.A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 by: Surveying by: SCALE DRAWN JOB. NO. TOTAL AREA: .............................................................. 471.2 S.F.Engineering 86.5 144" Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 255-15 DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD PERC RATE <2 MIN/IN. "C" HORIZON 12 West Crossfield Road 2854 Cranberry Hwy. SHEET N0. DATE CHECKED NO GROUNDWATER ENCOUNTERED Forestdole, MA 02644 (508) 477-5313 E.Wareham, MA 02538 (508) 273-0377 1/15/16 P.T.M. 2 Of 2