Loading...
HomeMy WebLinkAboutEngineered Plan - 2016*23.83' PRECAST H-10 RISERS (TYP.) 2'0 *23.68' SYSTEM PROFILE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION PROVIDE MIN. 20" DIAM. WATERTIGHT (NUI IU SCALL) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILECONCRETE COVERS TO WITHIN 3" GRADE FILTER FABRIC OVER STONE 24.9' MINIMUM .751 OF COVER OVER PRECAST F2% SLOPE REQUIRED OVER SYSTEM 24.0' , NOTE: 2" MIN. WALL THICKNESS REQUIRED BLOCKS OR 4"0SCH40 PVC MORTAR ALL PRECAST RISERS 6" MIN. SUMP PIPES LEVEL 1ST 2' ' COMPONENTS H-10 12" MIN. INT. DIM. 4 ENDSJ a (TYP') 20.8 10" 1500 GAL H-10 14 SIDES � 21.63' • 0000°°°° .. ... , . ... ... :... .. .:...:.... ... ... .. ;00000000 TEE SEPTIC TANK TEE 5� o 0 0 0 0 0 0 0 o �0�0 21.16 1.91 ° ° ° ° ���0 �0�0 000 0 °°°°° WATERTEST D'BOX °o°o°o° . oaa000aaoMZ ®ij aaoa�� 7. GAS BAFFLE:: ° ° ° ° b °0°0 oa0000aa�®a ®������DODO '0000000°°° °o"'�'� FOR LEVELNESS ci 0000 ° ° °° ° °o°o°o°o aao�aaaa®aa ®aoaoa®aa�� :00000, �o 4' LIQ. LEVEL (ACME OR EQUAL) 21.9' 21.73' >00-0-000 :00000000 18.8 10 D0o0o.o�o�o;o'0000000�oco�o�o�ono'000000 I L 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED �6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' - COMPACTION. (15.221 [21) r (10 % SLOPE) FOUNDATION 25' SEPTIC TANK (LONGEST RUN) LEGEN D 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING ( 1 % SLOPE) 1' D' BOX (_ % SLOPE) 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 1/20/16 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS ELEV. 1 Opp 24.3' LS 12" 1OYR 4/2 B LS 30" 1OYR 5/6 21.8' C PERC MS 2.5Y 7/3 126" 1 113.8' NO GROUNDWATER ENCOUNTERED INCE #16-004 13.8' BOTTOM TH-1 NO GROUNDWATER FOUND LEACHING FACILITY NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP NOT TO SCALE ASSESSORS MAP 78 PARCEL 273 SITE IS LOCATED WITHIN A ZONE II 2 BEDROOM DEED RESTRICTION REQUIRED SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD -USE "A_ 330_ GPD DESIGN FLOW - - _.- - __ - - I SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND Yarmouth Health Department SPP VES hme Date MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #103 CAPTAIN BACON ROAD SOUTH YARMOUTH, MA PREPARED FOR a� NMq OF A,. DANIELA. tiN��HOFhc o OJALA DANIEL �� CIVIL 1 1 � A. 'A ' No. 46502 �Q_Y+is OJALA �� s T eR� No. 40980 'S" NAL Ed °� SCF �0\41 Scale: 1 "= 20' �( 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P.E., P.L.S. B&B EXCAVATIONMEBERT DATE: JANUARY 26, 2016 off 508-362-4541 I fax 508-362-9880 downcope.com down cape ezo ' eerki7e. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-004 B&B-HEBERT.DWG