Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 20155�9 SCALE: 1"=30' I = 30i r� i� C � °� � %t l L � � � 1 � t✓ JANUARY 25, 2015 REV: MARCH 4, 2015 REV: MAY 4, 2015 YARMOUTH 0 LOCUS z 0 U Q R LOCUS MAP LOCUS INFORMATION TITLE REF: BK 3742 PG 035 ZONE: R-40 PLAN REF: BK 205 PG 135 F: 30' S/R: 20' PARCEL ID: MAP 134 PAR. 3.3 LOT AREA: 24,000 SF NOT IN ZONE OF CONTRIBUTION BLDG AREA: 2,439 SF COVERAGE: 10% PROPOSED DWELLING SITE AND SEWAGE PLAN LOCATED AT: 21 ACORN HILL DRIVE YARMOUTH, MA PREPARED FOR BOB DUNPHY DUBLIN COMPANIES �P��� OF Mqs, R�YKES �_D R EI No. 35418 " No. 1144 RE6ISTE.�D 'VITAR\P EASTBOUND LAND SURVEYING P. 0. BOX 442 FORESTDALE, MA 02644 508-477-4511 SHEET 1 OF 2 LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE —98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— PROPOSED WATER SERVICE Q TEST PIT 5�9 SCALE: 1"=30' I = 30i r� i� C � °� � %t l L � � � 1 � t✓ JANUARY 25, 2015 REV: MARCH 4, 2015 REV: MAY 4, 2015 YARMOUTH 0 LOCUS z 0 U Q R LOCUS MAP LOCUS INFORMATION TITLE REF: BK 3742 PG 035 ZONE: R-40 PLAN REF: BK 205 PG 135 F: 30' S/R: 20' PARCEL ID: MAP 134 PAR. 3.3 LOT AREA: 24,000 SF NOT IN ZONE OF CONTRIBUTION BLDG AREA: 2,439 SF COVERAGE: 10% PROPOSED DWELLING SITE AND SEWAGE PLAN LOCATED AT: 21 ACORN HILL DRIVE YARMOUTH, MA PREPARED FOR BOB DUNPHY DUBLIN COMPANIES �P��� OF Mqs, R�YKES �_D R EI No. 35418 " No. 1144 RE6ISTE.�D 'VITAR\P EASTBOUND LAND SURVEYING P. 0. BOX 442 FORESTDALE, MA 02644 508-477-4511 SHEET 1 OF 2 T.O.F. , EL: 101.7 PROPOSED OUTL EL. 97.50 (MAX DEPTH) F.G.EL: 100.70 INV. 97.15 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS NOTE: PLACE RISERS OVER ALL COVERS W/IN 6" OF GRADE /-- F.G.EL: 100.2 F.G. EL: 100.0 TOP TANK=EL. NOTE: PLACE METAL RINGS AND COVERS RISERS OVER LEACHING RISERS FINISHED GRADE (100.0) MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED ,� .� DOUBLE WASHED"STONE STONE OR FILTER FABRfC s., 4" SCH 40 PVC 10" I �6w�14" 1% //MIN. TEES ARE TO BE INV,96.60 (MIN. ) 4" SCH 40 PVC 2 EFF. DEPTH INV.96.90 GAS 1 DB - BAFFLE PROPOSED DB - 3 :.:....:,........... ��20) DISTRIBUTION SOX INV. ELEV.= 96.00 PROP. 1,500 GALLON 'SEPTIC TANK " w4 GAS BAFFLE TO BE INSTALLED ON r`gsr9� OUTLET TEE AS MANUFACTURED BY (UTUF-TITE, ZABEL, OR EQUAL � CA�;,YEE 1� 4 No. 1i40 L) NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 13. NO PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. OTHERWISE) SEPTIC SYSTEM PROFILE SOIL LOGS ®a®®- 0 E3®®® UaE3aUUaUa®a ®®®®®®®®®®® ®®®®®®®®®®® 3' 4 X 8.5' 3' EFFECTIVE LENGTH = 40' TOP CONC. ELEV.= 97.0 INV. ELEV.= 96.0 BOTTOM EL.= 94.0 SEPARATION 5.30 FT. UST. GRNDWATER EL: 88.70 DATE: JANUARY 7, 2015 SOIL 'EVALUATOR: ()ARREN MEYER, CSE 1614 WITNESS: AMY VONHONE, YARMOUTH HEALTH Elev. TH - 1 Depth Elev. TI 7 - 2 Depth 99.40: A " 99.70 A 0" LOAMY SAND LOAMY SAND 10YR 3/2 10YR 3/2 98.73 $" 98.95 9" B B LOAMY LOAMY SAND SAND 10YR 6/6 10YR 6/6 96.73 32" 96.87, 34" C C BOTTOM PERC A SL 94.40 MEDIUM SAND MEDIUM SAND 2.5Y 6/4 '2.5Y 6/4 89.40 12,0" 88.70 1 132" I PERC RATEI <2 MIN/IN. ('C' HORIZON) NO GROUNDWATER OBSERVED i ' I, Darren M. Meyer, R.S., 'CSE, hereby certify that l lom currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify) that I have passed the Soil Evol. Exam in October, 1999. 2.50' 1 5 FT. BREAKOUT ELEV. = 9 7.0 2.50' I EFFECTIVE WIDTH = 10' 1 SOIL ABSORPTION SYSTEM (SECTION) (500 GALLON H2O LEACH CHAMBERS) DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 4 BR = DESIGN FLOW: 440 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 440 gpd x 200% = 880 gpd, USE NEW 1,500 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (440) = 594.59 S.F. .74 USE 'FOUR (4) 500 GALLON H2O PRECAST LEACHCHAMBERS W/ 2.25' STONE ON ENDS & 3' STONE ON SIDES: 40' L x 10' W x 2'D BOTTOM AREA: 40' x 10'= 400 SF SIDE AREA: (40 + 10) X 2 X 2 = 200 SF TOTAL SQUARE FEET PROVIDED = 600.0 vs. 594.59 REQ'D DESIGN FLOW PROVIDED: 0.74(600 S.F.) = 444 G.P.D. vs. 440 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 21 ACORN HILL DRIVE, Prepared for: Dunphy/DL System Design by: Survey by: MEYER & SONS, INC. EASTBOUND PO BOX 981 LAND SURVEYING P.O. BOX 442 EAST SANDWICH, MA 02537 FORESTDALE, MA 01644 508-362-2922 508-477-4511 YARMOUTH, MA blin Companies SCALE DRAWN DATE N.T.S. DMM 01/25/15 REV DATE REV DATE SHEET NO. 03/04/15 05/04/15 2 of 2