Loading...
HomeMy WebLinkAbout29.101.2 - Proposed Subsurface Sewage Disposal System (Copy 2)10' min. from - PROPOSED Foundation house to septic tank) Septic tank coven must be T.O.F. Slay. - 16.00 within a In. or Finished grade *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. w ovir Septic Tank - 15.00 Grad. over 0 -Bo. - 15.00 e.w SAS - EIEV• 15.00 NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITHIN 6' BELOW GRADE PERCOLATION TEST Date of Percolation Test: APRIL 12, 2006 Test Performed By. BSC GROUP Results Witnessed By. AMY VON HONE, R.S. ( YARMOUTH B.O.H.) Excavator: UNKNOWN Percolation Rate: 2 min./Inch O 42" BELOW GRADE. Test Hole No. 1 / / S - 0.02 Loamy Sand 3 HOLE IOYR 4/3 114.67 PL S-0.04 (H-20) DIST. BDX J' Mad...Cow. Top of SAS-Ebv.• 17.00 14' NEV PIPE n NEW 1,500 GAL 25. - 0.070' per foot • rn«ti.. dou FROM FOUNDATION ri SEPTIC TANK 5' e ��• Effftil a D.PM Bw H-10 FENCE 1 It R N N o ri 4' ~ 4' CONCRETE FULL FOUNDATIO � II 10.00 - I 4 I o V 11 II s 12 SYSTEM PROFILE 80'-132-1 u u u z I Effective Meth I > Not to Scale , - i i s• sTRlrouT ALL AROUND a L To cLEvAnv lua J c c - 0 0 Ca 6 In.of 3/4"-1 1/2' u Hotton of Test Hole a Rev.- 3.50 compacted stone w Obs. Croundsnter - Test Note I Elev.- 3.5 V A01 Groundwater - Test Hots, I Elev.93.20 7rj NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITHIN 6' BELOW GRADE PERCOLATION TEST Date of Percolation Test: APRIL 12, 2006 Test Performed By. BSC GROUP Results Witnessed By. AMY VON HONE, R.S. ( YARMOUTH B.O.H.) Excavator: UNKNOWN Percolation Rate: 2 min./Inch O 42" BELOW GRADE. Test Hole No. 1 DEPTH SOILS ELEV. 0 15.00 SPOT ( Loamy Sand DENOTE IOYR 4/3 114.67 PL 0•_8• Ar 13.50 97---------97 Loamy n 1 10 YR 5/8 PERCOL 8"-24' Bw 13.00 FENCE Sandy Loam PRIVATE REVISIONS 1018 5/4 13.50 24'- 60' Q 10.00 Med. Sand EHI' 10YR 7/1 80'-132-1 C• 4.00 Perc #'1 0 Test Hole #I Depth to Perc: 24' to 42" Perc Rate= 2 min./inch Groundwater Observed m ELEV 3.5 0 TH-2 BOTTOM OF TEST HOLE Elev. = 132' MIW-29/ZONE A - INDEX = 8.2 for 4/06 ADJUSTMENT 11.3 FEET ADJUSTED H2O Elev. Q.9 SECTION A -A PTOFILE VIEW OF LEACHING SYSTEM Not to Scale e" of I/!• - 1p• rw rMwe C PVC (CAPPED) NSPECT1pNCr'�I PONT TO eE NSTAt1EO AND TO BE 'im le" or DRADE 6 Units 2 7' e Effective Length SOIL ABSORPTION SYSTEM (SAS) NUT INLE TYPICAL 1500 GALLON SEPTIC TANK NOT TO SCALE 3-24• DIAM. ACCESS MANNOLES STEEL REINFORCED PRECAST CONCRETE PLAN VIEW l 3-24• REMOVA&Z COVERS THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT SHALL BE RAISED TO MITHIN 6' OF FINISHED GRADE. INSTALL TUf-TITE GAS BAFFLES OR EQUALS ON ALL OUTLET TEE ENDS Test Hole No. 2 DEPTH SOILS ELEV. 0 14.50 SPOT ( Loamy Sand DENOTE 1018 3/3 PL 0'-12' Ar 13.50 97---------97 Loamy Sonc DEEP T 10 YR 5/a PERCOL 12'-42• Be 11.00 FENCE COARSE SAND PRIVATE REVISIONS 10 YR 8/4 13.50 42'- 132 G EHI' 1r 5-e'005" OM xN�v� 4' - SCH. 40 Tes-' %R' PLAN SECTION CROSS-SECTION 3 HOLE DISTRIBUTION BOX - H-110 LOADING NOT TO SCALE cavo Number of Bedrooms: 4 Equivalent to 440 Col./Doy Garbage Grinder No Leaching Capacity Proposed: 440 Gal./Day Septic Tank : - 2 x Gal./Dey - .4160' USE NEW 1,500 GAL Septic Tank. SOIL ABSORPTION AREA: tb51ng percolotion rate of <2 min./inch Bottom Area: 0.74 gal/sq. ft. x 420sq. ft. = 311 gallons Sdewall Area 0.74 gol./sq. ft. x 188 sq. ft. - 139 gallons Providing: - 450 gallons Use: (4) 3050 H-20 INFILTRATOR CHAMBERS, HAVING A 2' EFFECTIVE DEPTH, (4' W x 7' L) TO BE USED WITH 4' OF WASHED STONE ON THE SIDES AND 4' OF WASHED STONE ON THE ENDS. PREPARED FOR: MR. PAUL SCHLAEGAL 25 BROWNFIELD ROAD BRIDGEWATER, MA 02324 (508)-292-8183 S.WehbeAvd4 - o or a4 1ae'd C. tntr 4 a M to a ►an Fiw,.e4eeta4eMwla•nNA.N. N1 GENERAL NOT 1. Contractor is responsible for Dig! and protection of all undergrounl 2. The septic tank an$ distri ution level on 6' of 3/4 -1 1�2" sto 3. Backfill should be clean sand or stones over 3' in size. 4. This system is subject to inspect by Carmen E. Shay - Environme 5. The contractor shall install this I with Title V of the Mossachusett! and Local Regulations. 6. If, during installation the controc soil conditions or site conditions from those shown on the soil to installation must halt h immedio made to Cormen E. Shay - Env 7. No vehicle or heavy machinery is septic system unless noted as H 8. install Tuf-Tito gas baffles or eq 9. All Distribution Lines shalt be 4" 10. All solid piping, tees & fittings Schedule 40 NSF PJC pipes wit) 11. MUNICIPAL WATER is AVAILABLE NOTE THE PROPERTY LINES AND WELTLAND THE BASE PLAN AND SURVEY DATA C BSC GROUP OF YARMOUTH, MA, DATE ENTITLED"EASEMENT PLAN OF LAND C PROPOSED LOT COVERAOE - 2.3 PERCENT PROPOSED HOUSE - 1966 S.F. LOT SIZE 84,287 S.F. THERE ARE WETLANDS LOCATED WIT WETLAND FLAGGING AND BASE MAP G DATED DECEMBER 14, 2005 ZONING DISTRICT = R-25 SETBACK RQUIREMENTS FRONT = 30' SIDE = 15' REAR - 20' ASSESSORS MAP - 29 PARCEL 10 FEMA FLOOD ZONE DISTRICT: FLOOD ZONE C AS SHOWN ON COMMUNITY PANEL 250015 0005 C LEGEND 8X0 DENOTE SPOT ( X 104.46 DENOTE SPOT C PL PROPEf -[ED- PROPO! 97---------97 EXISTIN DEEP T PERCOL 0 WF#A2 WETLAN! o ----o FENCE PRIVATE REVISIONS NO. DATE: #1 7/24/06 PROPOSE[ SUBSURFACE SEWAGE DISPC or OF °" T. LOT #4 BAXTER AV T. m yir YARMOUTH, M/ wI TAKE" I { SCALE: 1"=30' )JECT#SD-938pp.dwg PREPARED BY: CARHEN E. ENVIRONNENTAL SEA P.O. BOX 627 EAST FALMOUTH, MA 025; TEL/FAX : 508-539-7966 DRAWN BY: CES FILENAME: SD -938