Loading...
HomeMy WebLinkAbout19 Bass River Parkway - Proposed Septic Design 2BASS R/VER PARKWA Y J 9.3 LEGEND: EXISTING SPOT ELEVATION x0.0 EXISTING CONTOUR ----GO---- FINAL SPOT ELEVATION FINAL CONTOUR Qv SOIL TEST LOCATION UTILITY POLE ca� TOWN WATER -W-.�W CATCH BASIN �0j GAS LINEC G CESSPOOL CLEANOUT C.O. TOP OF FOUNDATION HORIZ SOIL COLOR SOIL 9.5 10 FT. MINIMUM TEST 1 CLEAN SAND TEST 2 /I / 24" HDCI MANHOLL INSPECTION PORT 3-10 E COVERS 4" SCHEDULE 40 PVC PIPE LOAM AND SEED B LOAMY SAND 10YR4/6 MIN. PITCH 1/8" PER FT. 2" LAYER OF - 10YR4/6 MEDIUM SAND 2.5Y7/6 1/8" TO 1/2- rn C -_- 1293 MAX. WASHED STONE VENT WITHIN 6" OF FINISHED GRADE. 8.6 3 ALL COMPONENTS OF THE SANITARY SYSTEM 10.68 MIN. REQUIRED FLOOD ELEV. 11.00_ (OR EQUAL) MINIMUM PITCH 1/4" PER FT. T Z 8.5 FLOW LINE � - m = 9.93 ELEV. -10.00---- . ELEV.10.75 _ r VENT \.3 +\94 ELEV. _ / 6" SUMP ELEV. 9.43 _ ELEV. _ _ Q��_ o 0 ELEV. LINER _E4 _ BGA EV DISTRIBUTION D. BOX LIQUID OUTLET '^ BOX - 9.43HIGH CAPACITY INRLTRATORS WTH STONE z_ 8 4 FEET TEE 14 INCHES (TO BE PLACED ON FIRM BaSE) TO BE WATER TESTED IN AN 11' 80' 10 " TRENCH FO4MA77ON •27 ELEV. _ _ LEGEND: EXISTING SPOT ELEVATION x0.0 EXISTING CONTOUR ----GO---- FINAL SPOT ELEVATION FINAL CONTOUR Qv SOIL TEST LOCATION UTILITY POLE ca� TOWN WATER -W-.�W CATCH BASIN �0j GAS LINEC G CESSPOOL CLEANOUT C.O. TOP OF FOUNDATION HORIZ 1. 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE COLOR 1242 ELEV. _ _-- 10 FT. MINIMUM 0-3 CLEAN SAND LOAMY SAND 10184/2 24" HDCI MANHOLL INSPECTION PORT 3-10 E COVERS 4" SCHEDULE 40 PVC PIPE LOAM AND SEED B LOAMY SAND 10YR4/6 MIN. PITCH 1/8" PER FT. 2" LAYER OF - 10YR4/6 MEDIUM SAND 2.5Y7/6 1/8" TO 1/2- 1.67* C -_- 1293 MAX. WASHED STONE VENT WITHIN 6" OF FINISHED GRADE. 4" CAST IRON PIPE 3 ALL COMPONENTS OF THE SANITARY SYSTEM 10.68 MIN. REQUIRED FLOOD ELEV. 11.00_ (OR EQUAL) MINIMUM PITCH 1/4" PER FT. T Z FLOW LINE � - m = 9.93 ELEV. -10.00---- SLAB ELEV. 11-5- ELEV.10.75 _ 10" MIN. 2 `ELEV. = 10• LEVEL e 3. 10. 0 8.80 40 ML VINYL ELEV. _ / 6" SUMP ELEV. 9.43 _ ELEV. _ _ Q��_ o 0 ELEV. LINER _E4 _ BGA EV DISTRIBUTION ELEV. _ LIQUID OUTLET '^ BOX - 9.43HIGH CAPACITY INRLTRATORS WTH STONE z_ 8 4 FEET TEE 14 INCHES (TO BE PLACED ON FIRM BaSE) TO BE WATER TESTED IN AN 11' 80' 10 " TRENCH FO4MA77ON •27 ELEV. _ _ 5 FEET 6 FEET 19 INCHES 24 INCHES 1500 GAl LO�i IF MORE THAN ONE OUTLET (TO BE PLACED ON FIRM BASE) WELL MIW 29 SOIL ABSORPTION A 7 FEET 8 FEET 29 INCHES 34 INCHES SEPTIC - TANK 3/4" TO 1 1/2" CLEAN ZONE INDEX 8.0 504) SYSTEM (H-20) DOUBLE WASHED STONE FREE OF FINES & SILT SSAS) 1 ADJUST 1.50 _ (H-2 / USGS PROBABLE WATER TABLE ELEV. _ - 3.33 c SEWAGE DISPOSAL STEM PROFILE OBSERVED WATER TABLE (6/21/04) ELEV. =_1.133-_ NOT TO SCALE BOTTOM OF TEST HOLE ELEV. = -=QM- SOIL TEST' DESIGN CALCULATIONS ' 24_ DATE OF SOIL TEST JUNE_ 2G,04 5 SOIL TEST DONE BY SWEETSERENGINEERING NUMBER OF BEDROOMS _ _ WITNESSED BY _@Sz_MLJKV�fY ____ - GARBAGE DISPOSAL UNIT �V��7Gpf�,r � ry ELEV.=_ 950_ 08smVAi1ON HOLE 2 ELEV.--9.5G ' TOTAL ESTIMATED FLOW Q GA X _.aACI BR.). _110- GAL./DAY nrenn•n^M CA= e 2 ulm /WCH TAY REQUIRED SEPTIC TANK CAPACITY _1149_ GAL. t,T 72INCHES PERCOLATION RATE -_<_-2-- MIN./INCH IN C HORIZON IR SEPTIC _ f 8. .3 LIMIT OF 5' GARPGE 50 40 A{L. VINYL RDIG11 LIFTER. 20.00. 1500 GALLON �1 tSEP C'TANK " (8) 8.1 • '8.4 -" ,; PROP BEORpO 18.0 ,-ry- ' 1 1 _ 5` 1 / 1 o Y ; 7:4�� 1 e J 1$I��u ).�lon 8.4 8.6 PgOXZ4 COHC APRON >� 1 � 20.0 '• 8 r'1.9 t LOT J u 20,605 f S.F. 7.4 'JF�KCtl 4P✓i ' Q1+C bCClW s r-- STREET 1�ttR/ VE I 1f DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-3 A LOAMY SAND 10184/2 NO E 3-10 E LOAMY SAND 10YR5/1 B LOAMY SAND 10YR4/6 10-28 B LOAMY SAND 10YR4/6 MEDIUM SAND 2.5Y7/6 FOR THE 28-120 C MEDIUM SAND 2.5Y7/6 WITHIN 6" OF FINISHED GRADE. WATER ENCOUNTERED AT _ '132"_ ELEV. = _ 1-93- DEPTH HORIZ TEXTURE COLOR MOTT, I OTHER 0-2 A LOAMY SAND 10YR4/2 NO 778.33 SO. FT. 2-9 E LOAMY SAND 10YR5/1 37.94 GAL.JDAY 778.33 X 0.74 9-27 B LOAMY SAND 10YR4/6 NOTES: 27-120 C MEDIUM SAND 2.5Y7/6 FOR THE SUBSURFACE DISPOSAL OF SEWAGE. ACTUAL SIZE OF SEPTIC TANK 1500 GAL. SOIL CLASSIFICATION J.__ DESIGN PERCOLATION RATE i