Loading...
HomeMy WebLinkAbout19 Bass River Parkway - Proposed Septic Design 4BASS RIVER PARKWA Y Safi 9.3 i i rl r i SOIL SOIL Q� 9.5 / / TEST 1 TEST 2 / r r f o l : o v 8.6 8.5��y���� VENT •\94 a\3 /''< 1 N'r ` 60 00 D. BOX � �9c3,• 91 \ TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR 1242 10 FT. MINIMUM 10 FT, MINIMUM FROM SLAB OR CRAWL SPACE ELEV. _ - 24" HDCI MANHOLL COVERS 4" SCHEDULE 40 PVC PIP MIN. PITCH 1/8" PER FT FLOOD ELEV. J11.00 I PITCH 1/4' PER FT. 4" CAST IRON PIPE (OR EQUAL) MINIMUM FLOW LINE MAX. 10.75 10" " ---7 SLAB ELEV. = 9.25 ELEV. _ MIN. 10 25 LEVEL _o HORIZ ELEV. _ -=-- VEL 6" SUMP 9.43 .r ELEV. GAS ELEV. _ _ 9.80_ ELEV. _ A LOAMY SAND _10_50_ BAFFLE DISTRIBUTION NO .3 LIMIT OF 5' GARAG;150 t� ELEV.3 LIQUID OUTLET �_�;ly' BOX A L 10-28 LI ER (TO BE PLACED ON FIRM UaSE) TO BE WATER TESTED IN 4DEPTH FEET 5 FEET 1TFF4 INCHES 19 INCHES 1500 GALLON! IF MORE THAN ONE OUTLET 6 FEET 24 INCHES (TO BE PLACED ON FIRM BASE) 7 FEET 8 FEET 29 INCHES 34 INCHES SEPTIC TANK 3/4" TO 1 1/2" CLEAN 27 ELEV. = TRENCH FORMATION (H-20) DOUBLE WASHED STONE --�_ FREE OF FINES do SILT j SSAS) ADJUST SEWAGE DISPOSAL SYSTEM PROFILE (H-2 NOT TO SCALE SERVED WATER TABLE (6/21/04) ELEV. _ SOIL TEST BOTTOM OF TEST HOLE ELEV. = =0,bQ_ .- 1117.7 , DATE OF SOIL TEST �ur1E 0, _2004_ TEST DONE BY SWEETSER ENGINEERING PR05 coBooM51NG r NUMBER OF BEDROOMS 5 SOIL WITNESSED BY OBSERVATION HOLE 1 ELEV.=_s so_ 00SERVATI0N HOLE 2 ELEV.=_9.50 carni ATIM RATE <2_ MIN./INCH AT __- INCHES - PERCOLATION RATE <_2-_ MIN./INCH IN C HORIZON _o HORIZ TEXTURE .r MOTT. OTHER 0-3 A LOAMY SAND 10YR4/2 NO .3 LIMIT OF 5' GARAG;150 E LOAMY SAND 40 AdL. VI O RDIG SLAB = 10-28 LI ER 2000' 10YR4/6 8.3 C 1500 GALLON 1162 - = LINER SEP CBTANK CH CAPACITYW1LTRATORS NTH STONE z 6'0 27 ELEV. = TRENCH FORMATION a INDEX 8.0 S 04) SYSTEM 1.50 j SSAS) ADJUST 8.1 (H-2 USGS PROBABLE WATER TABLE ELEV. _ _333 - SERVED WATER TABLE (6/21/04) ELEV. _ BOTTOM OF TEST HOLE ELEV. = =0,bQ_ .- 1117.7 , DESIGN CALCULATIONS PR05 coBooM51NG r NUMBER OF BEDROOMS 5 GARBAGE DISPOSAL UNIT - o - I O; 1. 1-L1t�G 1 '71 EX:7 SIN �R CEJ 1 - �M7 I I 1 1 r 1 lr - i � ' 11 -(6)� • 51 m T �48.4 ) X5/2- e / •;8.6 PgOX 24 1 rl •ij•8 tII, b�AaN. 12.9, I N LOT 3 LEGEND: ' i 20,605 L- S F. EXISTING SPOT ELEVATION •0.0 EXISTING CONTOUR ----00---- L „ . , , FINAL SPOT ELEVATION A cm- axnm i 7.4 FINAL CONTOUR SOIL TEST LOCATION ttcZ 0) �» �` Mcr¢) BO.� i UTILITY POLE TOWN WATER ®W=� W X81 TREET CATCH BASIN VO_7 GAS LINE C G ✓TBI R� VER S CESSPOOL CLEANOUT C.O. _ -. DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-3 A LOAMY SAND 10YR4/2 NO 3-10 E LOAMY SAND 10YR5/1 10-28 8 LOAMY SAND 10YR4/6 28-120 C MEDIUM SAND 2.5Y7/6 = LINER WATER ENCOUNTERED AT _52_ ELI�V. = 1 CLEAN SAND - HORIZ TEXTURE INSPECTION PORT MOTT. LOAM AND SEED 0-2 2' LAYER OF s 1/8" TO 1/2" WASHED STONE VENT E LOAMY SAND 10.68 MIN. REQUIRED 9-27 B LOAMY.SAND 10YR4/6 b, ELEV. s 10.00_ 3 C MEDIUM SAND 0 10' ° ELEV. s 8.60 40 ML VINYL = LINER CH CAPACITYW1LTRATORS NTH STONE z 6'0 27 ELEV. = TRENCH FORMATION WELL MIW 29 ;OIL ABSORPTION ZONES INDEX 8.0 S 04) SYSTEM 1.50 j SSAS) ADJUST (H-2 USGS PROBABLE WATER TABLE ELEV. _ _333 - SERVED WATER TABLE (6/21/04) ELEV. _ BOTTOM OF TEST HOLE ELEV. = =0,bQ_ DESIGN CALCULATIONS NUMBER OF BEDROOMS 5 GARBAGE DISPOSAL UNIT - o - TOTAL ESTIMATED FLOW ( 110 GAL/BR./DAY X SR.) _M0_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY 110- GAL. DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-2 A LOAMY SAND 10YR4/2 NO 2-9 E LOAMY SAND 10YR5/1 9-27 B LOAMY.SAND 10YR4/6 27-120 C MEDIUM SAND 2.5Y7/6 WATER ENCOUNTERED AT __92. ELEV. = -1 83._ ACTUAL SIZE OF SEPTIC TANK SOIL CLASSIFICATION �--- DESIGN PERCOLATION RATE 5�- MIN./IN. EFFLUENT LOADING RATE -014-GAL./DAY/S.F. LEACHING AREA 778.33 SQ. FT, (11X60)+(71X2X10/12) LEACHING CAPACITY (AREA X RATE) .5Z3,$4 GAL./DAY 778.33 X 0.74 RESERVE LEACHING CAPACITY 428,83 GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN to FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH 10, ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO FOR A MINIMUM OF 5 AROUND SOIL ABSORPTION SYSTEM AND BE OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. REPLACED WITH SAND AS SPECIFIED IN 310 CMR 15.255:(3)- 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION 11. ALL EXISTING UTILITIES ARE TO BE DISCONNECTED, REMOVED CONTRACTOR IS TO CALL 'DIG -SAFE" AT 1-888-344-7233 AND REPLACED WITH NEW SERVICES. I AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 12. EXISTING SEPTIC SYSTEM IS TO BE PUMPED AND REMOVED ALONG 7• CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL WITH ANY POLLUTED SOILS. AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. 13. A 40 ML VINYL LINER IS TO BE INSTALLED WHERE SHOWN. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIA LY. 8. PARCEL IS IN FLOOD ZONE A11 EL 11,0) 9. LOT IS SHOWN ON ASSESSORS MAP - 34 AS PARCEL X65 APPROVED: BOARD OF HEALTH DATE AGENT 2a PROPOSED SEPTIC DESIGN FOR N SHEET JOHNSON HOMES 's- MPI LOC.19 BASS RIVER PARKWAY f ' TAhrr - / SOUTH YARMOUTH, MASS. 'r• CAI(,+t STEETSER ENGINEERIhIG R 235 GREAT WESTERN ROAD gAss RIVER 508- P. 0. BOX 713 RKwA 39508- SOUTH DENNIS, MASS, 02660 PA i Q REv. RI F? sr. i m DATE JUNE 20, 2004 SCALE 1" _ 20' LOCUS G I1 REV. WClJti7: 1 REV.. JULY 13, 2004 JOB N0. .5999-00. REV. REV. 20041 SHEET 1 OF .1� NOV. 15, 2004 LOCATION MAP OCT. 18, C. 58PROJ 5999-00 dw 5999-sos3.DWO 02004 SWEETSER ENGINEERING