Loading...
HomeMy WebLinkAboutPlan used for PLS Referencer LEGEND LOCAL UPGRADE APPROVAL Existing Contour Titles 15.211 Minimum Set back Distances Proposed Contour x 37.5 Existing Spot Grade - YRB Fn S.A.S.. to Foundation 20 Ft. Required 43.1 Proposed Spot. Grade i 13 Ft. Provided w Water Service i ohu - overhead Utility Line(s) S.A.S. to Foundation Slab 10 Ft. Required u Uned d Ut'l't L'ne(s) 7 Ft. Provided 9 rgroun � i y � Gas Line i ® TH Test Hole and/or Boring Location 0• , [k Percolation TestLocation YRB Fn / o �`o�� p Concrete Bound (CB) Ly p�lS S.T. Septic Tank D.B. Distribution Box �. SAS. Soil Absorption System BENCHMARK RA Reserved for Future S.A.S. Top of Concrete Monument (CB) cob ® utility Pole Catch Basin Elev. =14.00 NGVD29 Fire Hydrant >- ISS ®� Leaching Catch Basin per Tree or Hedge Line / / Yarmouth Engineering Dept. [15.000] Reference to 310 CMR Title 5 // //i 4 Ft. of Stone Assumed ' I Q<p� TH-1 \+ s CB Fn LOT 9�o Area 9, 200 S F. f o. or 0.21 Ac.f \ �� �9 o��� IsrR j0� N�\�ohu �III�� �, \\� •� s • I �,� t�Je Igo `� 1�'s Approximate Location of -- f <� IQ Jed U.P. Existing Septic Components to be Pump & Removed' �o+\ o N � `�� foo. g + AO d �� G/Q 3'� 00� I�9 Permit v / �\ o �\ Qt ,gyp ' CFNLY, < co\ /� I/ Board of > 0 0- + Iv?) spy. tut 7 \ �' O. sb w:1ge fa 0 Existing o Green House 4- to be Relocated�atie W i s � ` RA OF T N7 0 �o • �'� yG DONALD T. C o POOLE O . �� No_32ii62 y s T 41`co G S4 t D 0 20 40 60 P. 28 Chatham, Mass. LOCUS �a 0, Silver leaf Ln �°� o�. a iP Rainbow ° m .c LOCUS PLAN ZONING REQUIREMENTS Zone R-25 Minimum Area 25, 000 S F. Q Minimum Frontage 150 Ft. Front Yard Setback 30 Ft. Side Yard Setback 15 Ft. oal Rear Yard Setback 20 Ft. �G Assessors' Map 22 Parcel 147 OWNER OF RECORD: Muriel E. Horgan Certificate No. 38386 Land Court Plan 11435-A, Lot 9 alit` for RFPAIid OF SEI �'IC SVSTFf69 lite *to State and I.utal s,.l,t, variances. ROBERT HORPAN ttealth review incl approv;il is re�uir�il for are additions/renov itions/alterati.•ns to eaitiesas,d/grstructuFesicl,,el,ing. 77 Silver Leaf Lane, West Yarmouth, MA Yarmouth health Department A PPR VE 1) CLARK ENGINEERING. LLC 156 Crowell Road Suite B, Chatham, MA. 02633 Date Tel.: (508) 945-5454; Fax.: (508) 945-5458 U a~ aC= WOUTERMOST LAND SURVEY, INC. 3904 Main . Street, Brewster, MA 02631 3:Tel.: (508) 255-0477, Fax. (508) 255-0577 SITE PLAN Rev. # Description of Revision Date hereby certify that the existing structures nd physical features depicted on locus as hown hereon are located as they exist on he ground. ate Date: 01-06-2015 Drawing No.: L.S. 1207010A Scale: 1 " = 20' Sheet No. 1 of 2 GENERAL NOTES DEEP OBSERVA T/ON HOLE LOG A.) Neither driveway nor Parking areas are allowed over septic system unless H-20 components are used and system is vented. PROFILE OF SYSTEM B.) The designer will not be responsible for the system as de- T.H.#1 T.H.#2 Not To Scale signed unless constructed as shown. Any changes must be Date of Test 12-17-14 Date of Test approved in writing by the designer. C.) Contractor shall be responsible for verifying the location of Existing Grade Existing Grade all underground and overhead utilities prior to the commencement Depth 0 14.0 Depth 0 of work. p P Top of Foundation 14.7 Finish Grade 14.4 Finish. Grade 14.4 8"min. Raise covers of the D -Box with pre -cast Raise covers of the septic tank with pre -cast concrete •:•:•:• " concrete water tight risers over inlet and FILL 6" wafer tight risers over inlet and outlet tees to within 6 outlet tees to within 6" of finish grade. CONSTRUCTION NOTES Elev. = I of finish g [ rade 15.228(2)]. - 13 36„ 1 4 G (0.75) .6 G Max.x. Elev. = 1.) Al/ construction shall conform to the State Environmental 14" 12.8 ( C1 00.75) 96 m°n 13.6 Code, Title 5 and the requirements of the local Board of Health IT J 2.) Topsoil, subsoil, peat, or other unsuitable or impervious A 00 1 .material [15.255 (1)] shall be removed five (5) feet laterally Loamy -IF1 in all directions beyond the outer perimeter of the soil absorp- Sand 1.59 minimum slope 19 minimum slope 19 minimum slope tion system to the depth of the naturally occurring pervious min. 6' min. materials) and replaced with fill material meeting the spec- / /cc 3/4 / Flow Line 4" schedule 40 PVC pipe " " " Outlet if/cat/ons of 310 CMR 15.255 3 , 15.255 5 p p 4 schedule 40 PVC pipe 6 min. pipes from D -box shall O [ O� 10 min. 14" remain level for at least 2 feet 3.) Septic tonk(s), grease trop(s), dosing chambers) and dist- 18" 12.5 1 before pitching to soil absorption ribution box(es) shall be set on a level stable base which has Schedule 40 1 system Elev. [15.232(3)(c)]. been mechanically compacted. If component is placed in fill, PVC Tee 48" min. Baffle Elev. Elev. = Elev. = proper compaction is required to ensure stability and to prevent = Elev. = Tuf-Ti;e 12.71 min* 12.50 (GB -11 12.25 12.19 12.02 settling; native ground with a 6 inch stone base is otherwise B adequate [15.221(2)]. Loamy * Re -Pipe as Necessary 4.) Base aggregate shall consist of 3/4" to 1-1/2" double Sand Distribution BOX washed stone free of iron, fines and dust and shall be installed 10 YR 5/8 DB -9 from below the crown of the distribution line to the bottom of the soil absorption system [15.247(1)]. Base aggregate shall be Septic ••tonk(s�••sha/l•tie.•instal%d •on•,'a •Ievel•atob%•tiase (.3O" X .J0"� covered with a 2" layer of 1/8" to 1/2" double washed stone Pipe Run that has been mechanically compacted and onto vhich 6 (10' min.) inches of crushed stone has been placed [15.228(1)]. free of iron, fines and dust [15.247 (2)]. 44" 10.3_ 5.) From the date of installation of the soil absorption system 14' - i 1500 gallon Polyethylene Septic Tank 6' --� 3' to 7' until receipt of a Certificate of Compliance, the perimeter of the soil absorption system shall be staked and flagged to prevent (1-i-10) the use of such area for all activities which might damage the system [15.246(2)]. 64" ® 8.7 6.) The Board of Health shall require inspection of all construction by on agent of the Board of Health and the designer and shall require such persons to certify in writing that all . work . has been completed in accordance with the terms of the permit and approved plans. 48 hours advance notice is requested. C Z) All system components shall be marked with magnetic marking tape or a comparable means in order to locate them once buried. Fine Sand 10YR 6/8 Elev. Arrows stamped on units _must point toward d -box __1.2.4 'Distribution lines `shall consist of 4" PVC schedule 40 backfill with clean sand to a -_NSF pipe [15.251(5)] with 3/8"_ to 5/8" orifices placed 6"' PVC depth of 9'; excluding topsoil - midway between the invert and centerline [15.251(8)]. 6 PVC inspection pipe Adj. gw 78" 6.5 brought to finish grade with cap. 0 0 0 0 0 0 0 0 O0 0O 00 0O 0O O0 0 O0 0O 0O OO O O O O 0 0 O0 O0 O no O ro= Og��•- - ��N OF IdgSSgi Elev. DAVID A. G .r 11.95 CLARK Elev. = o Cn } CIVIL . 11.95 N®. 41125 Obs. gw 120" 4.0Cultec Feld Drain Contactor C4 Leaching Chambers 5'Elev. 0 1 Starting Unit (closed) and 5 Intermediate Units (open) 1 11.70 .1Sl � xJ Adjusted Groundwater at e%=6.5 Representative of Approving Authority: Bottom of test hole elev. Amy Von Hone, R.S. Yarmouth Board of Health Soil Evaluator. • David A. Clark, P.E. - Clark Engineering Effective Lengh 48' Percolation Rate:,See SECT/ON A -A for' Further Details #1 - < 2 min. per inch in fine sand; Substratum C D HOR #2 - min. per inch in CUL TEC - Field Drain Contactor C4 t. -AN ROBERT Yes Wafer Encountered ® 120" Soil AbSorp th- System Appropriate Index well: MIW-29 77 Silver Leaf Lane, West Yarmouth, MA Water Level Range Zone: B Water Level for Index Well: 8.2 for Month - Year: 12-14 Adjustment 2.5 CLARK ENGINEERING LLC Observed Ground Water Elev.: 4.0 Adjusted Ground Wafer Elev.: 6.5 143 29. Slope minimj14.1 156 Crowell Road Suite B, Chatham, MA. 02633 3 Max. for mounded 1 system [15.255 (2)] Te %: (508) 945-5454; Fox.: (508) 945-5458 9" min. of compacted and 1.0' to be placed over system 1.0' 1._ 15' Min. --� SYSTEM DESIGN CALCULA TIONS -cover each row of chambers with SEWAGE DISPOSAL SYSTEM PLAN 1.) Basis of Design �- O O O O O O O O Cultec 410 engineering fabric or Number of Bedrooms: 4 equal Rev. # Description of Revision Date Other. 0.71' 2.) Design Daily Flow Sewage Flow: 440 GPD 3.) Septic Tank Capacity Required: 880 Gal. 1.0' 1.0' 1.0' 1.0' 1.0' 1.0' 1.0' 1.0' Provided 1500 Gal. 4.) Soil Absorption System Capacity I Effective Width 8' l Required: 440 GPD r- - Provided: 474* GPD 5.) A garbage disposal is NOT permitted with this design gal/SF. x 1.67 SF/SF** Date: 01-06-2015 Drawing. No.: * 8' x 4s x o.74 SECTION A -A ** per DEP Remedial Use Permit Not To Scale Scale: 1 " = 20' Sheet No.: 12o7o1oA 2 - Of 2