HomeMy WebLinkAbout34.236.1 - Title 5 Site PlanSYSTEM PROFILE TOP FNDN ELEV. = 11.0' ., 3 ACCESS COVERS TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) 4" PVC W/ FEMALE A CLEANOUT TO GRADE. t0.5 MINIMUM .75' OF COVER OVER PRECAST TYPICAL WHERE INDIC 0.33 POUR 1.5 CU. FT. MIN. 2% SLOPE REQUIRED OVER SYSTEM 3000 PSI CONC. 10.25' MIN. THRUST BLOCK M 0 AROUND CONNECTION 2" DOUBLE WASHED PEASTONE PROPOSED 2500 2"0SCH40 PRESSURE UNE 8 O+ 2" x 1.5" TEES OR ELBOWS & REDUCERS i. GAL ST/PC LQ,.JI� $ D, PITCH I COMBINATION \ SLAB ABOVE REAR GRADE r.' 8.25 (SEE DETAIL) .005 FT/FT MIN. \ \ 1.5'0SCH40 LATERAL 9.0 ELi= O' 0.58' (V.LF.) 2"OSCH40 PRESSURE LINE FROM PUMP PIT ( 2 �6" CRUSHED STONE OR MECHANICAL PITCH 2"OSCH 40 PVC MANIFOLD INV. 9.0 DEPTH OF FLOW = 4' COMPACTION. (15.221 [2)) % SLOPE) FLOODZONE FOUNDATION DESIGN TEE SIZES: REQUIRED (BY OTHERS) INLET DEPTH = 10 OUTLET DEPTH = 14" FOUNDATION- 10' ST - .BUOYANCY CALCS.:- 800 LBS UP, WT. 22,000 LBS O.K. 14' LEACHING FACILITY CENTER COVER OFFSET TO PROVIDE ACCESS TO ZABEL FILTER / ZABEL A700 -8X18 -VC FILTER WITH GAS BAFFLE ON BOTTOM \ WWW.ZABELIONE.COM 37.5' (9 QUICK4 INFILTRATORS tN EACH OF 2 ROWS) 2500 G BAFFLE AL, SEPTIC TANK/PULP CHAMBER COMBINATION SHOREY CONCRETE PRODUCTS OR EQUAL (NOT TO SCALE) 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, .DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. l BENCHVARK NAIL IN 12" PINE ELEV = 8.93' NGVD \ BRBBZY POINT ROAD WATERLINE TO BE RE-ROUTED EXIST. - __-___ EDGE OF PAVEMENT 1 `\. STONE ...� - __ 100' OFFSET a 1 n 3 1 6.0• m G t 3 C y STEPS _ S o 10. 2O1HI PERVIOUS 75 10.0 PROP DRIVEWAY 3i� SHR PROP. INTERLOCKING T BLOCK WALL RET. WALL 9.0' (DESIGN BY OTHERS) i 10.0 I N i TW = EL 40 7.d Itut = 27.� INE \" D r W RI( LIMI - t. �� t5 z � F Z Co, o 0 o a Li o° 0 ' _ #2 BVW X5 p4 PLANT WITH NATIVE SPECIES TO CREATE A - 10' BUFFER ZONE TO BVW. NO FURTHER EXPANSION OF LAWN TO REAR OF HOUSE COMBINED LOTS 11,753± SF TTL (7,735± SF UPLAND 4,018± SF WETLAND) "THE RUN" TIDAL \ \ SITE PLAN 20 0 20 40 60 1 " = 20' 05-204 PROVIDE APPROX. 142' OF 40 MIL. LINER ALONG, - INSIDE OF RETAINING WALL. AND ALONG FOUNDATION IN AREA SHOWN. TOP AT EL. 9.5', BOTTOM AT EL. 5.5' ALARM AND CONTROL PANEL WITNESS: AMY VON HONE, RS 2 267.16' TO Y. 113 PERC. RATE _ PROP. RET. WALL CLASS I { TO BE INSTALLED INSIDE -/ Q ELEV. 0" EXISTING 2 BEDROOM DWELLING L (HATCHED - TO BE REMOVED) BUILDING. ALARM TO BE ON .s J FS I EXISTING 10YR 7/1 SEPARATE CIRCUIT FROM PUMP NV. IN 16.5 Eli ll 2" FRESSURE LINE PROP. 24' x 32' DWELLING TOP FNDN ELEV. 11.0' 10" TEE 7/5YR 4/3 to" TEE SLOFE TO DRAIN BACK TO PC 2'M 330+ GAL 3.0' ELECTRICAL PERMIT C7 19" TEE FS 84" ALARM ON R R SERVE REQUIRED. SEPTIC TANK FS 10 0 GAL t WEEP,HOLE 1500 GAL. MIN. P/C CHECK VALVE PUMP ON THIS SIDE0.5' OF BAFFLE 'MYERS SRM 4 6" WORKING RANGE TANK AND PUMP CHAMBER TO 8E WATER PROOF - g 75• SUBMERSIBLE 4/10 HP PUMP 0.5 AND LEAK FREE. OVERNIGHT TEST OF TANK 5.25' UQ. LEVEL SYSTEM (OR EQUAL) PUMP OFF 2.0' REQUIRED AFTER BAFFLE INSTALLED. CLEAN TEST WATER TO ALSO BE PROVIDED FOR PUMP TEST. �o 00000000 00 0000 FLOAT SWITCH SETTINGS: 6" WATERTIGHT BAFFLE FORMING 2 COMPARTMENTS GAS 2500 G BAFFLE AL, SEPTIC TANK/PULP CHAMBER COMBINATION SHOREY CONCRETE PRODUCTS OR EQUAL (NOT TO SCALE) 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, .DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. l BENCHVARK NAIL IN 12" PINE ELEV = 8.93' NGVD \ BRBBZY POINT ROAD WATERLINE TO BE RE-ROUTED EXIST. - __-___ EDGE OF PAVEMENT 1 `\. STONE ...� - __ 100' OFFSET a 1 n 3 1 6.0• m G t 3 C y STEPS _ S o 10. 2O1HI PERVIOUS 75 10.0 PROP DRIVEWAY 3i� SHR PROP. INTERLOCKING T BLOCK WALL RET. WALL 9.0' (DESIGN BY OTHERS) i 10.0 I N i TW = EL 40 7.d Itut = 27.� INE \" D r W RI( LIMI - t. �� t5 z � F Z Co, o 0 o a Li o° 0 ' _ #2 BVW X5 p4 PLANT WITH NATIVE SPECIES TO CREATE A - 10' BUFFER ZONE TO BVW. NO FURTHER EXPANSION OF LAWN TO REAR OF HOUSE COMBINED LOTS 11,753± SF TTL (7,735± SF UPLAND 4,018± SF WETLAND) "THE RUN" TIDAL \ \ SITE PLAN 20 0 20 40 60 1 " = 20' 05-204 PROVIDE APPROX. 142' OF 40 MIL. LINER ALONG, - INSIDE OF RETAINING WALL. AND ALONG FOUNDATION IN AREA SHOWN. TOP AT EL. 9.5', BOTTOM AT EL. 5.5' ROP. 10' x 32' DEC 20 & THREADED PLUG 1.5"0 THREADED END CONNECTION ON END SWEEP ELL/RISER SCH 40 PVC TO WITHIN ,4" OF GRADE WEEP ELL OR (2) 45S 5. PIN AND BLOCK RETAINING WALL SEE DETAIL 5' USE ADJ. WATER AT EL. 3.5 y� NOTE: INSIDE DIMENSIONS SHOWN RET. WALL DIMENSIONS AT SAS SCALE 1"=10' INFILTRATOR STANDARD QUICK4 CHAMBER PRESSURE DOSING DETAIL 1.5"SCH40 PVC PRESSURE PIPE WITH HOLES AT 12 O'CLOCK ALL WEATHER PLASTIC - EVERY 5TH HOLE AT 6 O'CLOCK FOR DRAINAGE !EL. E STRAP WITH 120 POUNDS 2" DOUBLE WASHED PEASTONE SILE STRENGTH AT EVERY OVER DOUBLE WASHED 3/4"-1.5" STONE MBER CONNECTION (4' O.C.) LTRATOR QUICK4 STANDARD AMBERS 2 ROWS REQUIRED. N 8.5' CAP EL 9.5' �-�KEYSTONE UNIT (OR EQUAL) PROP. 40 MIL LINER 12 PROVIDE COARSE SAND BACKIILL BEHIND MASONRY BLOCK UNITS EXIST. GRADE ELEV. 6.0' - PROVIDE COARSE SAND OR PEASTONE BACKFILL DOWN TO FREE DRAINING CRUSHED STONE BASE- SOIL AT HEEL OF RETAINING WALL PIN AND BLOCK RETAINING WALL (NTS) CONSULT MANUFACTURER'S SPECS FOR DETAILED DESCRIPTIONS AND INSTALLATION. BATTER BACK PER SPECS. RETAINING WALL `SECTION: NOT TO SCALE 1.5" LATERALS WITH 1/4" NOTE: 7B CHAMBERS AND 26 ORIFICES TOTAL 2" CENTRAL FED MANIFOLD ORIFICES 3' O.C. STRAPPED CHAMBERS 4' GAP OVER CLEANOUT TO GRADE. 37.5' O.A. / I .75' 3 ivl 1.2' DOUBLE -WASHED STONE BETWEEN 2 ROWS OF 9 75' QUICK4 INFILTRATORS, .75' hh-- STONE AT ENDS, NONE AT OUTSIDE EDGES. LEA HING FIELD DETAILS 6.6' X 37.5' D.A. SCALE 1"=10' PRESSURE DOSE SPECIFICATIONS PERFORATION SIZE: 1/4" DIA. - DRILL WITH DRILL PRESS & CLEAN OUT SHAVINGS. PERFORATION SPACING: 36"I (3') ON CENTER AT 12 O'CLOCK POSITION (EXCEPT EVERY 5TH AT 6 O'CLOCK FOR DRAINAGE) LATERAL DIAMETER: 1.6" DIA SCH40 PVC MANIFOLD DIAMETER: 2" DIA SCH40 PVC PUMP: MYERS SRM4 4/10 HP SYSTEM OPERATES AT 14' TDH, 38 GPM± APPROX. 4' RESIDUAL HEAD (IN-LINE PRESSURE) > 2.5' O.K. 25 5075 / 100 SYSTEM CURVE CAPACITY GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP PUMP/SYSTEM CURVE 6.8' , INFILTRATOR DETAIL NOT TO SCALE SEPTIC DESIGN: TEST H0 IL OGS 3 WITNESS: AMY VON HONE, RS 2 267.16' TO Y. 113 PERC. RATE _ PROP. RET. WALL CLASS I T.W. ELEV. 9.5 Q ELEV. 0" EXISTING 2 BEDROOM DWELLING 6 (HATCHED - TO BE REMOVED) TOP FNDN -6.7' .s FS EXISTING 10YR 7/1 DWELLING 16.5 Eli B PROP. 24' x 32' DWELLING TOP FNDN ELEV. 11.0' FLOOD VENTS PER FOUNDATION 7/5YR 4/3 . DRAWING (BY OTHERS) ROP. 10' x 32' DEC 20 & THREADED PLUG 1.5"0 THREADED END CONNECTION ON END SWEEP ELL/RISER SCH 40 PVC TO WITHIN ,4" OF GRADE WEEP ELL OR (2) 45S 5. PIN AND BLOCK RETAINING WALL SEE DETAIL 5' USE ADJ. WATER AT EL. 3.5 y� NOTE: INSIDE DIMENSIONS SHOWN RET. WALL DIMENSIONS AT SAS SCALE 1"=10' INFILTRATOR STANDARD QUICK4 CHAMBER PRESSURE DOSING DETAIL 1.5"SCH40 PVC PRESSURE PIPE WITH HOLES AT 12 O'CLOCK ALL WEATHER PLASTIC - EVERY 5TH HOLE AT 6 O'CLOCK FOR DRAINAGE !EL. E STRAP WITH 120 POUNDS 2" DOUBLE WASHED PEASTONE SILE STRENGTH AT EVERY OVER DOUBLE WASHED 3/4"-1.5" STONE MBER CONNECTION (4' O.C.) LTRATOR QUICK4 STANDARD AMBERS 2 ROWS REQUIRED. N 8.5' CAP EL 9.5' �-�KEYSTONE UNIT (OR EQUAL) PROP. 40 MIL LINER 12 PROVIDE COARSE SAND BACKIILL BEHIND MASONRY BLOCK UNITS EXIST. GRADE ELEV. 6.0' - PROVIDE COARSE SAND OR PEASTONE BACKFILL DOWN TO FREE DRAINING CRUSHED STONE BASE- SOIL AT HEEL OF RETAINING WALL PIN AND BLOCK RETAINING WALL (NTS) CONSULT MANUFACTURER'S SPECS FOR DETAILED DESCRIPTIONS AND INSTALLATION. BATTER BACK PER SPECS. RETAINING WALL `SECTION: NOT TO SCALE 1.5" LATERALS WITH 1/4" NOTE: 7B CHAMBERS AND 26 ORIFICES TOTAL 2" CENTRAL FED MANIFOLD ORIFICES 3' O.C. STRAPPED CHAMBERS 4' GAP OVER CLEANOUT TO GRADE. 37.5' O.A. / I .75' 3 ivl 1.2' DOUBLE -WASHED STONE BETWEEN 2 ROWS OF 9 75' QUICK4 INFILTRATORS, .75' hh-- STONE AT ENDS, NONE AT OUTSIDE EDGES. LEA HING FIELD DETAILS 6.6' X 37.5' D.A. SCALE 1"=10' PRESSURE DOSE SPECIFICATIONS PERFORATION SIZE: 1/4" DIA. - DRILL WITH DRILL PRESS & CLEAN OUT SHAVINGS. PERFORATION SPACING: 36"I (3') ON CENTER AT 12 O'CLOCK POSITION (EXCEPT EVERY 5TH AT 6 O'CLOCK FOR DRAINAGE) LATERAL DIAMETER: 1.6" DIA SCH40 PVC MANIFOLD DIAMETER: 2" DIA SCH40 PVC PUMP: MYERS SRM4 4/10 HP SYSTEM OPERATES AT 14' TDH, 38 GPM± APPROX. 4' RESIDUAL HEAD (IN-LINE PRESSURE) > 2.5' O.K. 25 5075 / 100 SYSTEM CURVE CAPACITY GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP PUMP/SYSTEM CURVE 6.8' , INFILTRATOR DETAIL NOT TO SCALE SEPTIC DESIGN: TEST H0 IL OGS ENGINEER: CRAIG SHORT, PE WITNESS: AMY VON HONE, RS DATE: 5/25/05 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. 0" 6.0' 26" 10YR 3/1 E FS 10YR 7/1 29" B LS 7/5YR 4/3 36" OBS WATER 3.0' C7 FS 84" tOYR 6/4 C2 (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: 2 BEDROOMS ( 110 GPD) = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2_) = 440 USE A 1500 GALLON SEPTIC TANK COMPARTMENT LEACHING: SIDES: 2(37.5 + F.8)l,58) (.'74) = 51 37.5 x 6.8 (.74) = 188 BOTTOM: TOTAL: 323 S.F. 239 GPD USE 2 ROWS OF 9 QUICK4 INFILTRATORS, WITH 1.2' STONE BETWEEN ROWS (0.75' AT ENDS, NONE ON SIDES) PRESSURE DOSE PEF PLAN. **2 BEDROOM DEED RESTRICTION REQUIRED LEGEND PS l.J WATER GATE OCATCH BASIN PROPOSED CONTOUR �) UTILITY POLE _�-- ORIFICE ON LATERAL �C O CLEANOUT EXISTING CONTOUR 50.5 PROPOSED SPOT GRADE +49.40 EXISTING SPOT GRADE CP EXISTING CESSPOOL E ELECTRIC LINE S SEWER LINE -W-W- WATER LINE G GAS LINE - 0 AIR VENT, FORCE AIR LINE G� lJ GAS GATE FIRE HYDRANT S'YQ TH TEST HOLE �•�- EXIST. TREES SEPTIC INSPECTIONS: INSPECTIONS BY OWNERS ENGINEER REQUIRED FOR SEP n, SYSTEM: 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION S COMPLETE. (UNSUITABLE SOIL REMOVAL) 2. ENGINEER SHALL STAKE FOOTING PRIOR TO WA PLACJENT 3. ENGINEER SHALL INSPECT WHEN CLEAN FILL HATS BEEN ROPERLY DEPOSITED (UNSUITABLE SOIL REPLACEMENT) 4. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPOF.NTS AND PUMP MECHANISMS AFTER INSTALLATION + LEAI TEST 1.FFLE TANK. INSTALLER SHALL PROVIDE WATER FOR CLEARW'pTER Ti ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH EPARTMIIT THAT THE RETAINING WALL. SEPTIC SYSTEM AND PUMP 1pECHANl:�,4 HAVE BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE AIROVED PLAN. � INSTALLER SHALL NOTIFY HEALTH DEPT. OF ALL I SPEC'l HEALTH DEPARTMENT TO INSPECT AS REQUIRED. Yarm®61�'FiD ,fns 1i OF 11TH MA APPROVED DATE fox 508-362-4541 fax 506 362-9880 down cape nglneel g, CIVIL ENGINEER LAND SURVEYOR 939 main st. yarmouth, �a 026 LOCATION MAP NTS ASSESSORS MAP 34 PARCEL 236 ZONING DISTRICT: R-25 YARD SETBACKS: FRONT = 30' SIDE = 15' REAR = 20' FLOOD ZONE: A11 ELEV. 11 (ENTIRE LOT) GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 0.5 VARIANCES REQUESTED: TOWN OF YARMOUTH REG 3.7: REDUCTION IN SETBACK TO WETLAND (100' TO 85' - A 15' VARIANCE) TITLE 5 VARIANCE REQUESTED: 15.211: REDUCTION IN SETBACK. SAS TO LOT LINE (10' TO 6') REDUCTION IN SETBACK, SAS TO FNDN (20' TO 18') 15.248: NO RESERVE REFERENCE: OB 13263 PG 164 OB 7738 PG 12 DB 1285 PG 1014 PB 72 PG 51 PB 607 PG 16 (LOCUS IS LOT B) SEE SPECIAL PERMIT #4010 RECORDED IN DB 20817 PG 39 NOTES. 1. VERTICAL DATUM IS NGVD29 2. MUNICIPAL WATER IS EXISTING (RELOCATION REQUIRED) 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOL 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JCN-JTS TO SC I'iA✓c 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC UNLESS NOTED. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING SEPTIC SYSTEM 11. LOT DOES NOT LIE WITHIN APD 12. DRYWELLS/DRIP TRENCH PROPOSED FOR ROOF RUN-OFF 13. FLOODZONE FOUNDATION DESIGN REQUIRED (BY OTHERS) FINAL GRADING AND FOUNDATION DESIGN TO CONFORM TO FEMA FLOODZONE REGULATIONS. ALL MECHANICALS SERVICING THE DWELLING, TO INCLUDE DUCTWORK AND EXTERIOR A/C UNITS, SHALL BE ABOVE THE FLOODZONE ELEVATION 11.0' 14. PLEASE REFER TO ORDER OF CONDITIONS FOR CONCOM REQMNTS. 15. CONTRACTOR TO NOTIFY DIGSAFE + VERIFY ALL UTILITY LOCATIONS. TITLE 5 SITE PLAN OF 126 BREEZY POINT ROAD IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: DAVID & LYNDA TAGLIAVINI 20 0 20 40 60 SCALE: 1" = 20' DATE: DECEMBER 16, 2005 REV 2/70/06 (CONCOM) REV 3/2/06 (WALL ) REV 4/6/06 (PRESSURE DOSE) ARNE P.E., P.L.S. DATE PILE COPY FILL 20" A L5 26" 10YR 3/1 E FS 10YR 7/1 29" B LS 7/5YR 4/3 36" OBS WATER 3.0' C7 FS 84" tOYR 6/4 C2 FS gg" 10YR 6/2 -2.0 OF 11TH MA APPROVED DATE fox 508-362-4541 fax 506 362-9880 down cape nglneel g, CIVIL ENGINEER LAND SURVEYOR 939 main st. yarmouth, �a 026 LOCATION MAP NTS ASSESSORS MAP 34 PARCEL 236 ZONING DISTRICT: R-25 YARD SETBACKS: FRONT = 30' SIDE = 15' REAR = 20' FLOOD ZONE: A11 ELEV. 11 (ENTIRE LOT) GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 0.5 VARIANCES REQUESTED: TOWN OF YARMOUTH REG 3.7: REDUCTION IN SETBACK TO WETLAND (100' TO 85' - A 15' VARIANCE) TITLE 5 VARIANCE REQUESTED: 15.211: REDUCTION IN SETBACK. SAS TO LOT LINE (10' TO 6') REDUCTION IN SETBACK, SAS TO FNDN (20' TO 18') 15.248: NO RESERVE REFERENCE: OB 13263 PG 164 OB 7738 PG 12 DB 1285 PG 1014 PB 72 PG 51 PB 607 PG 16 (LOCUS IS LOT B) SEE SPECIAL PERMIT #4010 RECORDED IN DB 20817 PG 39 NOTES. 1. VERTICAL DATUM IS NGVD29 2. MUNICIPAL WATER IS EXISTING (RELOCATION REQUIRED) 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOL 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JCN-JTS TO SC I'iA✓c 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC UNLESS NOTED. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING SEPTIC SYSTEM 11. LOT DOES NOT LIE WITHIN APD 12. DRYWELLS/DRIP TRENCH PROPOSED FOR ROOF RUN-OFF 13. FLOODZONE FOUNDATION DESIGN REQUIRED (BY OTHERS) FINAL GRADING AND FOUNDATION DESIGN TO CONFORM TO FEMA FLOODZONE REGULATIONS. ALL MECHANICALS SERVICING THE DWELLING, TO INCLUDE DUCTWORK AND EXTERIOR A/C UNITS, SHALL BE ABOVE THE FLOODZONE ELEVATION 11.0' 14. PLEASE REFER TO ORDER OF CONDITIONS FOR CONCOM REQMNTS. 15. CONTRACTOR TO NOTIFY DIGSAFE + VERIFY ALL UTILITY LOCATIONS. TITLE 5 SITE PLAN OF 126 BREEZY POINT ROAD IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: DAVID & LYNDA TAGLIAVINI 20 0 20 40 60 SCALE: 1" = 20' DATE: DECEMBER 16, 2005 REV 2/70/06 (CONCOM) REV 3/2/06 (WALL ) REV 4/6/06 (PRESSURE DOSE) ARNE P.E., P.L.S. DATE PILE COPY