Loading...
HomeMy WebLinkAbout25.351 - Site PlanN 4 LOCUS LOCATION MAP LOT 21 (7500 SF) ASSESSORS MAP: 25 PARCEL: 351 PLAN BOOK: 284, PAGE: 99 CURRENT ZONING: R-25 MINIMUM BUILDING SETBACKS: FRONT: 30' SIDE: 20' REAR: 20' FLOOD ZONE: B Q! Ok V V� Wq n� �a o BENCHMARK AT¢ GAS GATE 98.8 I ELEVATION = 9891 .` 99 EXISTING DWELLI REMOVED AND Rl (existing top fnd. _ (proposed top fnd. _ KEY: EXISTING CONTOUR: - - - PROPOSED CONTOUR: -•••-•^•••^••'•' EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE; * UTILITY POLE: -0-- FENCE LINE: -tJ� - - - HYDRANT: RETAINING WALL: JOB # M746 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS =_M0_ GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 12 INFILTRATOR CHAMBERS (QUICK 4 HI CAPACITY CHAMBERS) WITH WITH 1.75' OF STONE AROUND SIDES AND 1.5' AT ENDS (53'x 6.5'x 11" DEEP) SIDE AREA: (53' + 6.5') x 2 x ll/12 = 109 SF (0.74) = 81 GAL/DAY BOTTOM AREA: 53' x 6.5' = 344 SP (0.74) = 255 GAL/DAY C PACITY = 336 GAL/DAY 99 D,' TH� \,' r a DFCk N689'f OI0, 03 00, R� '5 8' 16' DK. i' 16.5' )N PORCH EXISTING DWELLING ELLING v ............ OSED ADDITION BE MOVED17500 AND REPLACED) Sr i 100 SEPTIC SYSTEM SECTION BENCHMARK AT WOOD STAKE ELEVATION = 100.0 BATH LIVING BED DECK ROOM KIT AREA DECK EXISTING FLOOR PLAN EXISTING SHED TO BE REMOVED Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department AutFROVLI) Wk COVERS WITHIN 12" OF FINISED GRADE (ONE INSPECTION COVER TO BE WITHIN 6" OF GRADE) 00 98.63 /9\ 8.46 ELEV. ELEV. D -BOX (6" OF STONE UNDER) GAS BAFFLE AT OUTLET TEE FILE GO 3' MAX. COVER (V MIN) e, 1.75'- 1.5 ELEV. 12 INFILTRATOR WITH 1.75' ADJUSTED 2" P ASTONE 3/4" -1 112" �-WASHED STONE INSPECTION PORT / ELEV.= 98.88 1.75' -1.5' -53'x6.5' 5 SRS (QUICK 4 HIGH CAPACITY CHAMBERS) fE AROUND SIDES AND 1.5' AT ENDS ;'x 6.5' x 11" DEEP) (TO BE VENTED) I i WATER ELEVATION = 92.5 TEST HOLE LOGS 101.5 / ELEV. 5" TOPOF FOUNDATION E HORIZON 2.5' LOAMY ISAND ENGINEER: RON CADALLAC, R.S. 99.0 IOYR 5/3 12" IOYR 5/3 ELEV. WTTNESS: AMY VON HONE, R.S. SANDY LOAM 98.9 '19 1500 GAL 36" ELEV. SEPTIC TANK PERCOLATION RATE: < 2 MIN/IN (6" OF STONE UNDER OR MECHANICALLY COMPACTED) 2.5Y 6/4 TEE SIZES: 112" OBSERVED INLET: 6" UP, 13" DOWN 1.91124" OUTLET: 6" UP, 14" DOWN INVERT OF OUTLET PIPE TO BE II 2.5' BELOW TOP OF FOUNDATION BENCHMARK AT WOOD STAKE ELEVATION = 100.0 BATH LIVING BED DECK ROOM KIT AREA DECK EXISTING FLOOR PLAN EXISTING SHED TO BE REMOVED Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department AutFROVLI) Wk COVERS WITHIN 12" OF FINISED GRADE (ONE INSPECTION COVER TO BE WITHIN 6" OF GRADE) 00 98.63 /9\ 8.46 ELEV. ELEV. D -BOX (6" OF STONE UNDER) GAS BAFFLE AT OUTLET TEE FILE GO 3' MAX. COVER (V MIN) e, 1.75'- 1.5 ELEV. 12 INFILTRATOR WITH 1.75' ADJUSTED 2" P ASTONE 3/4" -1 112" �-WASHED STONE INSPECTION PORT / ELEV.= 98.88 1.75' -1.5' -53'x6.5' 5 SRS (QUICK 4 HIGH CAPACITY CHAMBERS) fE AROUND SIDES AND 1.5' AT ENDS ;'x 6.5' x 11" DEEP) (TO BE VENTED) I i WATER ELEVATION = 92.5 TEST HOLE LOGS 6" FILL 11 ELEV. 5" FILL E HORIZON E HORIZON LOAMY ISAND ENGINEER: RON CADALLAC, R.S. 10" IOYR 5/3 12" IOYR 5/3 B HORIZON WTTNESS: AMY VON HONE, R.S. SANDY LOAM DATE: 2-28-07 96" IOYR 518 36" 10YR 5/8 C HORIZON PERCOLATION RATE: < 2 MIN/IN FINE SAND FINE SAND 2.5Y 6/4 USGS GROUND WATER ADJUSTMENT: 112" OBSERVED WELL: MIW-29, ZONE: A, ADJUSTMENT: 1.91124" GROUND WA' ADJUSTED GROUND WATER ELEV.= 92.5 II 99.5 TH-2 ELEV. 5" FILL E HORIZON LOAMY SAND 98.7 12" IOYR 5/3 B HORIZON SANDY LOAM 96.5 36" 10YR 5/8 C HORIZON FINE SAND 2.5Y 6/4 90.2 loll, nTtgFRvF.n NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM wil H AASHTO H-20 LOADING SPECIFIC) 5. PIPE PITCH = 1/8° PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENT, CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS I 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 11 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 11. ALL UNSUITABLE SOIL B HORIZON, APPROX. 36" DEEP) WITHIN 5' OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOW DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME, 13. EXISTING CESS POOL IS TO BE PUMPED AND REMOVE . REQUIRED VARIANCES FROM TITLE FIVE; 1. SECTION 15.211 (1): LEACH AREA TO BE LESS T�� N 20' FROM CELLAR WALL (VARIANCE OF 4.6'). 2. SECTION 15.211 (1): SEPTIC TANK TO BE LESS THAN 10' FROM CELLAR WALL (VARIANCES OF 2'). RICHARD HOOD, P.L.S. SITE Pi ,AN LOCATION: 38 B R CIRCLE, S. YARMOUTH, MA I" = 20' PREPARED FOR: ELLEN DUGGAN BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-385-3426