Loading...
HomeMy WebLinkAbout106.26.2 - Title 5 Site PlanI TOP FNDN. AT EL. 48.5' SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO 48.0' MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM �I 45.5'PROPOSEDD 1500 GALLON SEPTIC 45.30' TANK (H— 10 ) ( 2 % SLOPE) DEPTH OF FLOW = 4 TEE SIZES: INLET DEPTH = 10" OUTLET DEPTH - 14" FOUNDATION— 10' +46J RUN PIPE LEVEL FOR FIRST 2' 0 iI GAS 44.76' BAFFLE 44.93' 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 (21) (-Z-7 SLOPE) % SLOPE) +40.21 2" DOUBLE WASHED PEASTONE 3/4" TO 1 1/2" DOUBLE WASHED STONE SEPTIC TANK 6' D' BOX 12' LEACHING FACILITY BENCHMARK: NAIL IN 12" \ -{-40.24 PINE AT ELEV. 47.4' 02-206-11 xm 3' MAX. AROUND 5,16' 37.5' TEST HOLE LOGS ENGINEER: RICK JUDD, RS WITNESS: L. McCARTIN DATE: 9/10/02 PERC, RATE _ < 2 MIN/INCH CLASS I SOILS P# n" Q ELEV. 48.5' 0" N 4 48.5' 0 —� A/E LS 9„ 1OYR 5/6 BW LMS 36" 10YR 4/6 45.5' Cl LS 2.5Y 6/6 80" C2 MS 2.5Y 7/4 i _I 4f 0 LOCUS 5" 0 PARCEL P/0 26 YARD SETBACKS: A/E BRUSH = 25'1 CLUSTER LS = 12'� 91, 10YR 5/6 A Y1P�c1US 4i PLAN REF. LOCATION MAP ( NTS CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. :R4 38" 00Y/6 45.3' 7. C1 IS NOT 2(25 + 12.83) 2 (.74) _ 12 COS TO BE USED FOR ANY OTHER PURPOSE .1 2.5Y 6/6 SIDES: 96" " PIPE FOR SEPTIC SYSTEM TO SCH. 40-4PVC. 25 x 12.83 (.74) _ 37 BOTTOM: C2 COMPONENTS NOT TO BE BACKFILLEDIOR CONCEALED WITH[ MS INSPECTION BY BOARD OF HEALTH AND PERMISSION 2,5Y 7/4 ,349 _GPD 132" FROM BOARD OF HEALTH. N 4 48.5' 0 —� A/E LS 9„ 1OYR 5/6 BW LMS 36" 10YR 4/6 45.5' Cl LS 2.5Y 6/6 80" C2 MS 2.5Y 7/4 i _I 4f 2. LOCUS ASSESSORS 0 PARCEL P/0 26 YARD SETBACKS: BRUSH = 25'1 CLUSTER ag OZ = 12'� JA`'MME REAR A Y1P�c1US 4i PLAN REF. LOCATION MAP ( NTS 37_5' 129" �_� 37.75' NO WATER ENCOUNTERED NOTES' 1. DATUM IS ASSUMED SEPTIC DESIGN: (GARBAGE DISPOSER IS Nnr AI 1 QMED ) 2. MUNICIPAL WATER IS AVAILABLE ASSESSORS MAPI106 PARCEL P/0 26 YARD SETBACKS: FRONT = 25'1 CLUSTER SIDE = 12'� SUBDIVISION REAR = 20 PLAN REF. — 469/97 FLOOD ZONE: C 37_5' 129" �_� 37.75' NO WATER ENCOUNTERED NOTES' 1. DATUM IS ASSUMED SEPTIC DESIGN: (GARBAGE DISPOSER IS Nnr AI 1 QMED ) 2. MUNICIPAL WATER IS AVAILABLE OJALA y CIVIL ItSiGN FLvvi: BEDROOMS ( 110 GPD) = 330—GPD 3. MI"d;MUM PIPE PITCH TO BE 1/8" PER FOOT. —3 USE A 330 GPD DESIGN FLOW 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H— 10 SEPTIC TANK: 330 GPD ( 2 ) = 660 5. PIPE JOINTS TO BE MADE WATERTIGHT. 1 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. USE A 15OQ GALLON SEPTIC TANK ENVIRONMENTAL CODE TITLE V. I LEACHING: 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT 2(25 + 12.83) 2 (.74) _ 12 TO BE USED FOR ANY OTHER PURPOSE .1 SIDES: B. " PIPE FOR SEPTIC SYSTEM TO SCH. 40-4PVC. 25 x 12.83 (.74) _ 37 BOTTOM: 9. COMPONENTS NOT TO BE BACKFILLEDIOR CONCEALED WITH[ TOTAL: 472 S.F. INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAIN ,349 _GPD FROM BOARD OF HEALTH. 3 USE (2) 500 GAL LEACHING CHAMBERS (ACME OR 10. WATER TEST D'BOX FOR LEVELNESS. EQUAL) WITH 4' STONE ALL AROUND LEGEND 100.0 PROPOSED SPOT ELEVATION 100xO EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR — 100— EXISTING CONTOUR -- U BOARD OFHEALA• 0C� JG v MA APPROV DTE off 506-362-4541 fox 506 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main St. yarmouth, ma 02675 TITLE 5 SITES PLAN_ OF # 32 BRUSH HAL ROAD IN THE TOWN OF: YARMOUTH PORT PREPARED FOR: OUR FIRST HOME, l INC 0 SCALE: 1 = 20' DATE: DECEMBER 10, 2002 �" OF t q�yG ARNE H. �o� ARNE OJALA y CIVIL 44 H. OJA1A n No. 30792 o y„ No 2634. ARNE H OJALA, P.EyP.L.S. DATE FILE Cfmy -FILE COPY !FILE COP