Loading...
HomeMy WebLinkAbout96.40 - Title 5 Site PlanLEGEND 1OO.Q PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION F _ 100 _ PROPOSED CONTOUR — 100 EXISTING CONTOUR W PROPOSED WATER BICE ##02-206 SYSTEM PROFILE PROP. TOP FNDN. AT EL. 40.0' ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT To SCALE) ACCESS COVER TO WITHIN 3' OF FIN. -GRADE ACCESS COVER (WATERTIGHT) TO 38.0' MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM zl ri•� INSTALL INLET TEE 1" ABOVE 37:0' OUTLET]INVERT - .75' 35.0'1213, AS 8" SUMP 33.57' MIN. (2.5% SLOPE) \_6' CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) DEPTH OF FLOW = 4' TEE SIZES: INLET DEPTH = 10_ OUTLET DEPTH = 14" FOUNDATION— 18' — SEPTIC TANK (39 % SLOPE) — 3' — PIPE LEVEL / 2" DOUBLE WASHED PEASTONE FIRST 2' OR GEOTEXTILE FABRIC 0.4' L 4 DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW 0" SEPTIC TANK: 330 GPD (2) = 660 37.3' 0^ ED =1 O pppp = 33.3` _ pppp SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD p pppp o GPD p p p p E3 p p ED p 2-1 pppp p pppp 3/4" TO 1 1/2" DOUBLE WASHED STONE (-!—X SLOPE) 37.2', B D' BOX 12' B LEACHING LS .., 32" FACILITY oP0 J REQUIRED AROUND OF PERIMETER OFLLEACHNGPORTI]IFACILITY; DOWN TO SUITABLE SOIL LAYER REPLACE WITH CLEAN MED. SAND. A \ / / / /41 / X42 / / / / / / / 3' MAX. 5' BOTTOM TH-1 EL. 26.3' NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO "BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND.' 12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT -ALLOWED L 4 DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW 0" SEPTIC TANK: 330 GPD (2) = 660 37.3' 0^ USE- A 1500 GAL. SEPTIC TANK 38.0' LEACHING: 0/A/E SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM'25 x 12.83 (.74) 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4 STONE ALL AROUND 1OYR 4/2 APPROVED , MA DATE BOARD OF HEALTH FILE COPS' V �\ s. a :6 LOCUS Route 6 LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 96 PARCEL 40 LOCUS IS WITHIN FEMA FLOOD ZONE 'C' AS SHOWN ON COMMUNITY PANEL #250015 0003 C DATED JUNE 17, 1996 TEST HOLE ..LOGS ENGINEER: DAVID FLAHERTY, R.S. WITNESS: PHIL RENAUD, YBOH DATE: JANUARY 16, 2007 PERC. RATE _ < 2 MIN/INCH {ASSUMED) CLASS I SOILS P# TITLE 5, SITE PLAN OF 61 BRUSH -HILL RD. YARMOUTH (PORT), MA PREPARED FOR OUR FIRST- HOME DATE: FEBRUARY 9, 2007 REV. DATE:` SEPTEMBER 24, 2007 (BLDG ENVELOPE) ...: me (I' �egzrL. •c . Scale: 1"=20' 0 10 20 30 40 .-50 FEET �--� off 508-362-4541 FILE COPY fax 508 362-9880 '(H OF MASy�c/Y /.� �`N.qC 1 w `T, i•..�.'.� oDANIELA. aN �� DANIEL down cape en gin eerin g, Inc. OJALA c A k CIVIL OJALA H tj - - 502 4 No.40990 Cl l�lL ENGINEERS P�ARF /STE���?� 9OF 5l P NAL EAG D �, LAND SURVEYORS 1 DATE DANIEL H. OJALA, P.E., P.LS` 939 Main Street — YARMOU THPOR T, Mil SS. 02-206OUR-FIRSTHOME TOPO LOTS 4-7.9,10.DWG (DDF; L 4 ELEV. W Q ELEV. 0" 37.3' 0^ 38.0' 0/A/E 0/A/E LS LS 10" 1OYR 4/2 36.5'" 9 1OYR 4/2 37.2', B B LS LS .., 32" 1OYR 4/ 6 34.6' 36" 10YR 4/6 35.0 C C MS MS 2.5Y 5/6 2.5Y 5/6 132" 126.3', 120" 28.0' NO GROUNDWATER ENCOUNTERED TITLE 5, SITE PLAN OF 61 BRUSH -HILL RD. YARMOUTH (PORT), MA PREPARED FOR OUR FIRST- HOME DATE: FEBRUARY 9, 2007 REV. DATE:` SEPTEMBER 24, 2007 (BLDG ENVELOPE) ...: me (I' �egzrL. •c . Scale: 1"=20' 0 10 20 30 40 .-50 FEET �--� off 508-362-4541 FILE COPY fax 508 362-9880 '(H OF MASy�c/Y /.� �`N.qC 1 w `T, i•..�.'.� oDANIELA. aN �� DANIEL down cape en gin eerin g, Inc. OJALA c A k CIVIL OJALA H tj - - 502 4 No.40990 Cl l�lL ENGINEERS P�ARF /STE���?� 9OF 5l P NAL EAG D �, LAND SURVEYORS 1 DATE DANIEL H. OJALA, P.E., P.LS` 939 Main Street — YARMOU THPOR T, Mil SS. 02-206OUR-FIRSTHOME TOPO LOTS 4-7.9,10.DWG (DDF;