HomeMy WebLinkAbout30.274 - Septic System Design (Copy 2)CC 63 ...... ........ .. ACCESS COVERS MUST BE WITHIN 6' OF FINISH GRAD 103.5 FIRST 2' TO 8E LEVEL7 LOCUS MA Gas 99.35 "2",99.081 I/O III �Ccl 98.1 BAFFLE 3 OUTLET 6 HIGH CAPACITY INFILTRATOR 1500 GAL D -BOX CHAMBERS W/3.5'± STONE AROUND 2-10'• X 25.'1 X l0'd SEPTIC TANK 6' CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE / 6 HIGH CAPACITY INFILTRATOR CHAMBERS 9/3.5'+ STONE AROUND CATCH BASIN RIM -99.54 9' MINIMUM. 3' MAXIMUM COVER MIN 2' OF PEASTONE 3/4' - 1 1/2' DIA. DOUBLE WASHED STONE INVERT ELEVATIONS: DESIGN CRITERIA: INVERT AT BJILDING: 100.0 DESIGN FLOW: INVERT IN SEPTIC TANK: 99.75 4 BEDROOMS AT 110 G.P.D. PER INVERT OUT SEPTIC TANK: 99.5 BEDROOM EOUALS 440 G.P.D. INVERT IN DIST. BOX: 99.35 INVERT OUT DIST. BOX: 99.18 NO GARBAGE GRINDER INVERT IN LEACH CHAMBER: 99.0 SEPTIC TANK REQUIRED:q40 BOTTOM OF LEACH CHAMBER: 98.17 G.P.D. X 200% - 880 GAL. ADJUSTED GROUND WATER: N/A SEPTIC TANK PROVIDED: 1500 GAL. MIN, OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE •l.• 91.4 SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED PROVIDED: 6 HIGH CAPACITY INFILTRATOR CHAMBERS W/3.5'1 STONE AROUND. A-600 S.F. 600 S.F. x 0.74 - 444 GPD SOIL TEST PIT DA TA INDICATES INDICATES PERCOLATION OBSERVED TEST GROUNDWATER TP *1 TP *2 0• HORIZON TEXTURE_ COLOR 101.9 O' HORIZON TEXTURE COLOR .101.9 OO LOAMY 10YR -FILL SAND 4/3 q• ........... 101.6 7' .......................................... /01.3 LOAMY E IOYR LOAMY IOYR Q /� SAND 5/1 SAND 4/2 /0'--.. ..................................... 10/.0 /0 .......................................... 101.0 B W LOAMY IOYR p LOAMY IOYR - SAND 4/6 W D SAND 5/8 20 . ..,...................................... 100.2 20' ......... 100.2 B2 LOAMY IOYR B2 LOAMY IOYR SAND 6/8 SAND 6/6 5 • ............. 99.8 42' ..... ....... ............... .. 98.4 C/ FINE -MED 2.5Y C FINE -MED 2.5Y SAND 7/4 SAND 7/4 -L 91.4 120'1 NO WATER 91.9 DATE: OCTOBER 4, 1997 TEST BY: DAVID MASON WITNESSED BY: RICK JUDD PERC RATE: l 2 MIN/INCH GENERAL NOTES: 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EOUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. I -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. ALL UNSUITABLE MATERIAL (A A 8 HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. 9. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 10. lT SHALL REIAAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. SEPT/ C SYS7`EM DES / 0/V 1-4 CADET LANE. MAP 30. PARCEL 274 r� - WES T YA A? "0 U TH 4 "A - PREPARED FOR MR MR S . / O H/V /V / CK,g /VO R O S 220 ME -S7- P0/V0 S TREET . EAS T% SR / DGEWA TER . MA 02333 20' wO VEMBER 9 . 200 / EAGLE SURVEY I NO I NC 923 Route 6A Ydrmouthport MA. 02675 /CT ` -2,/I �i%11/1�1� f.. (508) 362-8132 / I ( 508 ) 432-5333 o !o 20 40 JOB NO: 01-080 F/ELD:CFW/AFW CALC: SAN/CFW CHECK: CFW DRN: SAH e.