Loading...
HomeMy WebLinkAboutEngineered Plans - 2015JOSHUA BAKER R❑ PLACE MAGNETIC LOCATOR TAPE OR METAL OBJECT AT D BOX, SEPTIC TANK CLEANOUT PORT, AND INSPECTION PORTS. - / S39° 43' 15" E : INSTALL 15' BY 30' BED 123, 67:' 14 I G ❑HW W I I I ftrah vaNd for RWAtR OF SZFM SYSTIC14 014LY, dae to State sad Local se>pilk vwbutm Board of Nestth review sad appreval is "40Ued tar MY ad' slreasva�sas/ t! setes`t fat ies a straewrretJdwcN Ys moutl► HeafEh ffewrtme CATCH BASIN I I I I I I I I I BM; TOW / i= 14. 5 /.3, BR W -BOX DWELLING L17 00 / ABANDON 7 EXISTING - EXISTING U \ 1500 GAL W N o IN I SYSTEM SEPTIC \.ON LO TANK DECK z PR❑VIDE RISERS \. TO D—BOX ANDr/ INSTALL 4" PERFORATED PIPE \❑IdW / SEPTIC TANK INTO LEACH BED DOWN TO \ TO WITHIN 6" / BED BOTTOM. PIPE TO HAVE \ OF GRADE / SCREW ON TOP AND BE WITHIN 3" OF SURFACE. LOCATION \ \ — — — REMOVE ALL TOP501L AND SUBSOIL (A * B HORIZON) IN AREA BELOW \ AND TO 5 FEET ON ALL SIDES OF PROPOSED LEACHING FIELD. PLACE TITLE V SPECIFICATION FILL TO TOP OF BED. BOARD OF HEALTH TO BE NOTIFIED FOR BOTTOM INSPECTION PRIOR TO PLACEMENT OF FILL N39° 18' 31" W T= n l e i VARIANCE REQUEST: 4' GROUNDWATER SEPARATI❑N RATHER THAN 5' n CIVII L ENGINEERING ASSOCIATES CIVIL ENGINEERS • LAND/SITE PLANNERS PO BOX 916 SOUTH [DENNIS, MA Tel (413) 246-9804 1 J't. 7`f FLAN UI EW SCALE: 1 "= 20'-0" DESIGNED BY: L�NOFMq R.M.0 DRAWN BY: ROW R.M.0 DATUM: MSL BM: SILL ELEV 14,5' HORIZONTAL SCALE: "= 20'-0" VERTICAL SCALE: NONE CHECKED BY: DATE: R. M. C 1 2/ 1 5/ 1 5 ENG\ APPROVED BY: PROJECT NUMBER: R.M.0 15-720 -� AWt s- r� V , r L] BR3 BA BR2 C=l SECOND FLOOR KITCHEN BA BR1 DINING LIVING FIRST FLOOR L] Q C=l o JOSHUA BAKER o � f r AM❑S ROAD 0 v, z 3 3 ROUTE 28 w Q Q W LOCUS = 0 PROPERTY LINES FROM SURVEY PLAN BY OTHERS NO OTHER WELLS OR WETLANDS LOCATED WITHIN 1 50' OF LEACHING FACILITY. \ \ r LEGEND: O CATCH BASIN 0 EXISTING CONTOUR PROPOSED CONTOUR PROPERTY LINE PERCOLATION TEST HOLE NO.: DATE: REVISION PROPOSED SEWAGE DISPOSAL SYSTEM - PREPARED FOR: SHEET NUMBER KEVEN CONBOY 59 1WIN5LOW GRAY ROAD WEST YARMOUTH, MA55ACNU5ETT5 I of 4 PLAN VIEW I ( N N QD z (n C) X z O w � II w w 30 LF OF PERF 4" 5CHED 40 w > > AT 0.5% SLOPE > EXISTING z O 1 2 LF OF 4" PVC z z_ z PLUMBING w w AT 1 % SLOPE TOW= 14.5' z z FINISHED GRADE FINISHED GRADE A 13 \ EXISTING SEPTIC TANK INVERT AT FOUNDATION = EXISTING (12.3') go G" MIN DISTRIBUTION BOX ---\\- J' — 1 5' BY 30' BED 3 OUTLET J/ 2' MIN. LEVEL BOTTOM OF BED 4' MIN. SEPARATION EL.= 10.62' LOAM AND SEED VARIANCE REQUESTED GROUNDWATER : ADJUSTED HIGH GW @ G.G' Pf�OE=I LE SCALE: NONE FINISHED GRADE (2% MIN.) 12" MINIMUM COVER 2" MIN. OF 1/8" - 1/4" DOUBLE WASHED STONE 3/4" - 1 112" DOUBLE WASHED STONE 4" PERFORATED PVC PIPE (TYP.) 5-0" (TYP.) 5'-0" CKC)SS SECTION SCALE: 1/2"= 1'-0" CIVIL ENGINEERING ASSOCIATES CIVIL ENGINEERS • LAND/SITE PLANNERS PO BOX 916 ENNIS, MA SOUTH TENNIS, Tel (413) 246-9804 ��`"��M��y ROB T M. AF VI LLI 3002 cn °9 9 �O �Q � FEP � GIST ass/ONALEN�\ DESIGNED BY: R.M.0 HORIZONTAL SCALE: I =2o " NO.: DATE: REVISION PROPOSED SEWAGE DISPOSAL SYSTEM PREPARED FOR: f, KEVEN CONBOY 59 WI NSLOW GRAY ROAD WEST YARMOUTH, MASSACHUSETTS ' SHEET NUMBER 2 of Q DRAWN BY: RMC VERTICAL SCALE: AS NOTED CHECKED BY: R.M.0 DATE: 12/15/15 APPROVED BY: R.M.0 PROJECT NUMBER: 15-720 PROFILE AND CROSS SECTION 2"Iv,.. REMOVABLE COVER 1 i" NAIKI 2" (TYP . ) PR❑VIDE RISERS TO D -BOX AND SEPTIC TANK TO WITHIN 6" OF GRADE 5" DIA. INLET ITLET COMPACTED SUB -BASE F ISE C AST C O N C INET E [DISTF;�,'IBUTI(DN BOX SCALE: I"= 1'-0" MIN. WALL THICKNESS: 3" W/ REINFORCING 4" W/O REINFORCING MIN. FLOORTHICKNE55: 3" W/ REINFORCING 4" W/O REINFORCING G' -O" MIN.* 1 2" MAX. (TYP.) * MIN. INSIDE LENGTH TO WIDTH RATIO MUST BE GREATER THAN OR EQUAL TO 1 .5: 1 REMOVABLE COVER (TYP. -3) 4" MIN. r — 3" MIN. (TYP.) 20" MIN. MANHOLE r �-'�. (TYP.-3) � G" MIN. (TYP.) 7 FEET OUTPUT ELEVATION �jNOF,yqR.M.0 RO RT A cn 30026 �c9F-/STIEV, SSS/ONAL ENG\ DESIGNED BY: OUTLET TEE 2" MIN. TO EE TABLE 3" MAX. = BELOW VERTICAL SCALE: AS NOTED z_ CHECKED BY: R.M.0 w o APPROVED BY: R.M.0 o C) GAS BAFFLE DEPTH OF OUTLET TEE C' 141NCHE5 J 19 INCHES 24 INCHES 29 INCHES s 34 INCHES COMPACTED SUB -BASE F IZE C AST C O N C SET E SEFTIC TANK SCALE: 3/8"= 1'-0" MINIMUM REQUIREMENTS FOR D. BOX * TANK: 1. CONCRETE STRENGTH OF 4000 PSI AT 28 DAYS. 2. REINFORCING PER ASTM AG 15 FOR WIRE FABRIC, GRADE 40 OR GO WITH I " COVER. l9mCIVIL ENGINE=ERING )%NSOCIATES CIVIL ENGINEERS • LAND/SITE PLANNERS PO BOX 97 6 SOUTH [DENNIS, MA Tel (41 3) 246-9804 �jNOF,yqR.M.0 RO RT A cn 30026 �c9F-/STIEV, SSS/ONAL ENG\ DESIGNED BY: HORIZONTAL SCALE: I"=2o' NO.: DATE: REVISION PROPOSED SEWAGE DISPOSAL SYSTEM PREPARED FOR:SHEET KEVEN CONBOY 54 WINSLOW GRAY ROAD WEST YARMOUTH, MASSACHUSETTS NUMBER 3 of Q DRAWN BY: RMC VERTICAL SCALE: AS NOTED CHECKED BY: R.M.0 DATE: 12/15/15 APPROVED BY: R.M.0 PROJECT NUMBER: 15-720 DIST. BOX & SEPTIC TANK DETAILS GENERAL NOTES I CONSTfZUCTION NOTES DESIGN CALCULATIONS 1. ALL UNDERGROUND UTILITIES (WATER, GAS, ETC.) SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. AS REQUIRED BY STATE LAWS, THE INSTALLER MUST CONTACT "DIG -SAFE" (1 -800- DIG5AFE) THREE BUSINESS DAYS PRIOR TO ANY DIGGING. 2. ALL WORK t- MATERIALS SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 (3 10 CMR 15.00) PLUS ALL OTHER BOARD OF HEALTH REGULATIONS APPLICABLE TO THE INSTALLATION OF THIS SYSTEM. 3. THE INSTALLER SHALL VERIFY LOCATION OF PROPERTY LINES AND ALL SITE CONDITIONS *- DIMENSIONS PRIOR TO THE INSTALLATION OF THE SEWAGE DISPOSAL SYSTEM. THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY UPON THE DISCOVERY OF DIFFERING CONDITIONS BETWEEN THE REQUIREMENTS OF THIS PLAN AND THE SITE. 4. THE ELEVATIONS SHOWN ON PLAN ARE BASED ON A TEMPORARY BENCH MARK (TBM) VALUE AS ESTABLISHED BY THE ENGINEER, REFER TO PLAN FOR LOCATION OF TBM AND GIVEN DATUM VALUE. 5. AT NO TIMES SHALL HEAVY CONSTRUCTION EQUIPMENT OR TRUCKS PASS OVER ANY PART OF THE SEWAGE DISPOSAL SYSTEM. IF THE INSTALLER REQUIRES CROSS -OVERS, THE ENGINEER MUST BE NOTIFIED. G. A MINIMUM OF 24 HOURS NOTICE MUST BE GIVEN TO THE ENGINEER PRIOR TO ANY INSPECTIONS OF THE SEWAGE DISPOSAL SYSTEM. 7. THE SYSTEM SHALL BE LEFT OPEN FOR AN INSPECTION BY THE ENGINEER AND THE BOARD OF HEALTH AGENT AND WILL NOT BE BACKFILLED UNTIL A CERTIFICATE OF COMPLIANCE HAS BEEN ISSUED. BOH MUST BE NOTIFIED FOR A BOTTOM INSPECTION AFTER EXCAVATION CIVIL ENGINEERING STH OF Mq ASSOCIATES �P ROBERT CIVIL ENGINEERS • LAND/SITE PLANNERS A CI ` PC:) BOX 916 30026 SOUTH UENNIS, MAGISTEP���� 9 O 2 Tel 413 246-9804 sF� `S�ONAL EN I . CHECK CONDITION OF EXISTING OUTLET BAFFLE AND REPLACE IF NEEDED. 2. ALL PIPING DOWNSTREAM OF THE SEPTIC TANK SHALL BE SCHD 40 SEWER PIPE. THE INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF ASTM STANDARD D232 1. 3. INSTALL ONE (1) NEW PRECAST CONCRETE DISTRIBUTION BOX MEETING THE REQUIREMENTS SHOWN IN DISTRIBUTION BOX DETAIL. i. 4. INSTALL ONE 1 5' BY 30' BED. REFER TO PROFILE FOR REQUIRED ELEVATIONS. i 5. REMOVE ALL TOPSOIL AND SUBSOIL (A * B HORIZON) IN AREA BELOW AND TO 5 FEET ON ALL SIDES OF PROPOSED LEACHING FIELD. PLACE TITLE V SPECIFICATION FILL TO TOP OF UNITS. REMAINING FILL MAY BE ORDINARY SITE FILL, SIMILAR TO EXIST. SOILS FOUND ON SITE. G. LINES OUT OF DISTRIBUTION BOX SHALL BE LEVEL FOR A MINIMUM OF TWO FEET DEEP OBSERVATION 1-10LE # 1 03/12/08 EL. 12.50' NOTE: WELL MIW-29 READ I NG: FEB 2, 2008 ADJUSTMENT: 2.4' USE 1.1' ADJUSTED GW ELEVATION ELEV G.G' OBSERVED ELEV GW 5. 5' = 88" 1 O" FILL 8 LS AE 12 LS 5w 24 I C1 S 32' S C2 I I 7 132" PERC. DEPTH 150" FERC. RATE _ MIN./INCH DESIGNED BY: HORIZONTAL SCALE: R.M.0 1 1 "=20' DRAWN BY: RMC CHECKED BY: R.M.0 VERTICAL SCALE: NONE DATE: 12/15/15 APPROVED BY: PROJECT NUMBER: R.M.0 1 15-720 ESTIMATED SEWAGE FLOW: TYPE OF ESTABLISHMENT: Family Dwelling, Single UNIT: per bedroom NUMBER OF UNITS: 3 REQUIRED FLOW PER UNIT: 110 GPD/UNIT EXISTING OR PROPOSED ,�GARBAGE GRINDER?: NO 3 BEDROOMS x 110 GP[)/BEDROOM = 330 GPD FERC * SOIL DATA: FERC RATE: 2 MIN./INCH SOIL CLASS: 1 SOIL TEXTURE: S EFFLUENT LOADING RATE: .74 GPD/SF VOLUME OF SEPTIC TANK: EXISTING 1 500 GAL SEPTIC TANK TO BE USED. LEACHING AREA REQUIREMENTS: MIN. REQUIRED LEACHING AREA: (330 GPD x 1.0*) / (0.74 GPD/SF) = 44G SF *(1.0 FOR NO GARBAGE GRINDER; 1.5 WITH GARBAGE GRINDER) BOTTOM CAPACITY: 0.74 GPD/SF x 15' WIDE x I' LENGTH = 1 1. 1 GPD/LF TOTAL CAPACITY PER LINEAR FOOT: 0.0 GPD/LF + 1 1. 1 GPD/LF = 1 1. 1 GPD/LF REQUIRED LENGTH OF LEACHING FACILITY: (330 GPD) / (1 1. 1 GPD/LF) x 1.0* =29.7' TOTAL LEACHING CAPACITY PROVIDED: 30 LF x 1 1. 1 GPD/LF = 333 GPD > 330 GPD (OK) TOTAL LEACHING AREA: 0 + (I 5'X 30) = 450 SF > 44G SF (OK) *(1 .0 FOR NO GARBAGE GRINDER; 1.5 WITH GARBAGE GRINDER) N I(1Tr�-. 1. SOIL EVALUATIONS PERFORMED BY EAS SURVEY ON 3/12/05 2. SOIL EVALUATIONS WITNESSED BYYARMOUTH HEALTH AGENT 3. SEE ATTACHED SOIL EVALUATION SHEET FOR ADDITIONAL INFORMATION. DATE: REVISION PROPOSED SEWAGE DISPOSAL SYSTEM ,PREPARED FOR: SHEET NUMBER KEVEN CONBOY 59 WIN5LOW GRAY ROAD WEST YARMOUTH, MA55ACHU5ETT5 4 OF 4 NOTES & DESIGN CALCULATIONS