HomeMy WebLinkAboutEngineered Plan - Rev. 2015BM @ T.O.F 107.81 COVERS TO WITHIN 6" OF FINISHED GRADE - 107.0 F.G. OUTLET COVER 105.7 \ '0 TO GRADE 10" INLET TEE 06 104.66 14" OUTLET TEE FILTER 1500 GALLON H-10 MONO SEPTIC TANK 104.41 SEPTIC SYSTEM PROFILE not to scale PIPE TO BE LEVEL FOR 2' OUT OF D -BOX 04.07 102. 104.24 H 1 20 6 HOLE D -BOX, WATER TEST FOR EQUAL FLOW WHEN USING MORE THAN ONE OUTLET 6" COMPACT STONE OR COMPACTED B ASE Eage \ f water Scale: 1"=20' 0 20 40 60 62.5' X 34" TRENCH (10) INFILTRATORS HI CAPACITY H2O, NO STONE X 96.14 POND ELEV o 0 o oa ?J 7 LOCUST. ' 16at«ho..ne 5.01 WATER 1.1 WATER ENCOUNTERED 95.91 86.0 BOTTOM OF TEST HOLE #2 Permit valid for REPAIR OF SEPTIC SYS -1-E161 ONLI'; due to State and Local septic variances. Board of Ilealth review and approval is required for any. future additions/rends ations/aIterations to sewage facilities and/or structures/dwelling. Yarmouth lleal It lkpar[nrent ue4 Po� �o .�• ✓ I N :tee' D►te TEST HOLE LOG DATE: 8/12/15 TEST BY: MIKE O'LOUGHLIN WITNESS: AMY VONHONE PERC RATE: < 2 MIN TEST HOLE # 1 TEST HOLE # 2 n" 103.74 EL n" 8" FILL 103.07 E 10" A LOAMY SAND 102.9 EL 10Y 2/1 20" FINE SAND 101.84 EI 16" E 10Y 6/1 102.4 EL 18" BS LOAMY SAND 102.24 E'. 10Y 3/6 34" Bw LOAMY SAND 100.9 EL 10Y 5/8 C FINE SAND 2.5Y 6/4 120" 1 193.74 EL WATER ENCOUNTERED AT 94" - 95.91 EL ADJ WATER 2.1' - 98.01 EL EXISTING FIRST FLOOR EXISTING BASEMENT -I-"--p[ELFflwD S P �OujJF_h17l 1H i W1.1 wk; not to scale in -K r, m 12" FILL 102.5 EL 15" A LOAMY SAND 102.26 E 10Y 2/1 20" E FINE SAND 101.84 EI 10Y 6/1 24" BS LOAMY SAND 101.5 EL 10Y 3/6 40" BW LOAMY SAND 100.18 El 10Y 5/8 C FINE SAND 2.5Y 6/4 120" 93.5 EL WATER ENCOUNTERED AT 91" - 95.91 EL ADJ WATER 2.1' - 98.01 EL BOTTOM OF PERC 57" PRESOAK 3 MINUTES 13 SECONDS < 9" GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, ABOVE & UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00: TITLE V. 3. THIS PLAN IS NOT TO BE USED FOR PROPERTY LINE DETERMINATION. 4. DESIGNER TO INSPECT & CERTIFY OVER -DIG, WHEN REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL. 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 6. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE DISPOSAL. 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 8. IF SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG, CONTACT DESIGNER AND THE BOARD OF HEALTH. 9. IF AN OVERDIG IS REQUIRED, OR IF UNSUITABLE SOIL IS FOUND IN A & B LAYERS, CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) SHALL BE USED AS FILL MATERIAL, 5' AROUND AND UNDER S.A.S. 10. ALL 4" PIPE CONNECTIONS AT SEPTIC TANK AND D -BOX SHALL BE MORTARED IN PLACE. IF USING 18" PLASTIC RISER PIPES, THESE TOO SHALL BE MORTARED IN PLACE OR SEALED. NOTES -1.-REMOVE-THE EXISTING -SEPTIC- TANK, _D-BOX,»FLQW.-D11 FUSERS,_AND_ __,,_._,___ CONTAMINATED SOIL WITHIN THE NEW LEACHING AREA. 2. WATER SERVICE TO BE RELOCATED 10' FROM ALL SEPTIC COMPONENTS. IF THE EXISTING WATER LINE WAS USED FOR ELECTRICAL GROUNDING, THEN THE GROUNDING MUST BE REPLACED BY AN ELECTRICIAN. 3. REMOVE A & B SOILS IN OVERDIG AREA AROUND AND UNDER THE S.A.S., ACCORDING TO GENERAL NOTE 9. 4. INSTALL SILT FENCE ALONG 50' BUFFER FROM VEGETATED WETLAND DESIGN DATA DAILY FLOW: (3) BEDROOMS X 110 GPD = 330 GPD SYSTEM NOT DESIGNED FOR A GARBAGE GRINDER SEPTIC TANK: 330 GPD X 2 = 660 GPD USE: 1500 GALLON H-10 MONO SEPTIC TANK DISTRIBUTION BOX USE: DB -6 H-20 SOIL ABSORPTION SYSTEM: USE: (10) INFILTRATORS HIGH CAPACITY H-20, NO STONE 330/.74 = 445.95 445.95/7.79 SF/LF = 57.25 LF REQUIRED 57.25 LF/6.25 LF/UNIT = 9.16 UNITS REQUIRED - USE 10 UNITS 10 UNITS X 6.25 LF/UNIT = 62.5 LF X 7.79 SF/LF X .74 = 360.29 GPD VARIANCE REQUESTS 1. REQUESTING 1' RELIEF FROM THE ADJUSTED GROUNDWATER FROM WELL MIW 29 ZONE A 8/15/15 2. REQUESTING 25' RELIEF FROM THE TOWN OF YARMOUTH REGULATION 3.7 REQUIRING 100' SETBACK FROM WETLANDS HEALTH AGENT APPROVAL SEWAGE PLAN LOCATION: 60 ICE HOUSE ROAD SOUTH YARMOUTH, MA PREPARED FOR: ESTATE OF FAITH M. HALFYARD SCALE: 1" = 20' DATE: AUG 31, 2015 JOB NUMBER: REVISION: SHEET NUMBER: SEP 29, 2015 MAP: 59 PARC EL: 136 J. O'LOUGHLIN INC. 714 MAIN STREET, YARMOUTH PORT, MA 02675 (508) 362-4942 DATE ENGINEER: STEPHEN HAAS