Loading...
HomeMy WebLinkAbout2016 Jan 07 t � J.M. O'Reilly & Associates, Inc. LETTER OF Engineering&Land Surveying Services T 1573 Main Street,2nd Floor,P.O.Box 1773 ���� L Brewster,MA 02631 (508)896-6601 JA.N i 1 2016 Fax(508)896-6602 HEAITH DEPT. TO: DATE: JOB NUMBER: Town of Yarmouth 01/07/2016 6611AW Board of Health 1146 Route 28 REGARDING: South Yarmouth, MA 02664-4492 Locus: 94 Iroquois Blvd,Yarmouth , Shippinq Method: Regular Mail ❑✓ Federal Express ❑ __ __ Certified Mail � UPS � Priority Mail � Pick Up � , Express Mail � Hand Deliver � ' COPIES DATE DESCRIPTION Routine Operation and Maintenance Checklist for Perc-Rite Drip Dispersal system For review and commenfi � For approval: � As Requested: � For your use: � ' REMARKS: cc: John M. O'Reilly, P.E., P.L.S. Keith E. Fernandes, P.E. Client Oakson, Inc. ', From: els/KEF If enclosures are not as noted,kindly notify us at once . � ROUTINE OPERATION AND MAINTENANCE CHECKLIST FOR PERC-RITE DRIP DISPERSAL SYSTEM Address: 94 Iroquios Blvd,Yarmouth Date: 12/22/15 Homeowner: Tom Sheehan Operator: Keith E. Fernandes, P.E., WWTO 4M-Full #13240 �Ob #: 6611AW HISTORICAL DATA and CURRENT READINGS Previous flow meter reading: 93sao Design flow: 33o Date of last visit: ��i2�i2o�a Current flow meter reading: 12�9so Calculated water usage: 729pd Start-up dose rate Current dose rate ZONE 1: 2.1 GPM 2.z GPM ZONE 2: ZONE 3: ZONE 4: FIELD CONDITIONS A. Drip dispersal field: visible wet spots YES❑ NO� Comments: B. Air release valves: erosion YES❑ NO� leakage/spraying YES❑✓ NO❑ Comments: Release vatve broken.Replaced at time of inspection. PUMP CHAMBER/FLOAT OPERATION A. Floats match pin lights in control panel YESD NO❑ Comments: B. Alarm float working YES� NO❑ Comments: C. So�ids or scum present YES� NOD Comments: CONTROLPANEL A. Switches in AUTO position YESD NO❑ Comments: . • B. Peak Level light on YES❑ NOp Comments: C. Power and Run lights on (microprocessor) YES� NO❑ Comments: PUMP and VALVE OPERATION A. Pump in HAND position: flow meter running YES� NO❑ Comments: B. Zones 1-4 (one at a time): flow meter running YES� NO❑ ' dose rate correct YES 0 NO❑ flush rate > dose rate YES 0 NO❑ Comments: C. Disc filter back flushing: working properly YESQ NO❑ Comments: D. Disc filter inspection: excessive residue YES� NO❑ cleaning required YES� NO� Comments: E. Switches returned to AUTO position YES 0 NO❑ Comments: F. RESET/CYCLE START: functioning properly YES� NO ❑ ' Comments: ' G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO❑✓ : Comments: SEPTIC and/or PRE-TREATMENT TANKS ', '`No cover at grade for access to inspect. ', A. Examine and clean effluent filter: excessive residue YES❑ NO❑ Comments: B. Septic tank pumping recommended YES❑ NO❑ 1. Sludge depth: ' 2. Scum depth: Comments: C. Service pre-treatment system YES❑ NO❑ Comments: � � Operator signat � License No.13240 Comments/Observations: Green air release valve covers missing and should be replaced.Homeowner notified.