Loading...
HomeMy WebLinkAbout2015 Oct 15 , : . J.M. O'Reilly & Associates, Inc. LETTER OF Engineering&Land Surveying Services 1573 Main Street,2nd Floor,P.O.Box 1773 T� �-� ' ��l`:.�uL�."'`:�'- Brewster,MA 02631 ', (508)896-6601 ���' r Q ��1� , Fax(508)896-6602 ��; H�AL i i-I D�r�T. TO: DATE: JOB NUMBER: Yarmouth Board of Health 10/15/2015 1276AW 1146 Route 28 South Yarmouth, MA 02664 REGARDING: 3� Moss �oo� West Yarmouth, MA Shipping Method: Regular Mail ❑✓ Federal Express � ' Certified Mail � UPS ❑ Priority Mail � Pick Up � Express Mail � Hand Deliver � � COPIES DATE DESCRIPTION 1 10/15/15 Routine Operation&Maintenance Checklist For Perc-Rite Dispersal System For review and comment: � For approval: � As Requested: � For your use: � REMARKS: cc:John M. O'Reilly P.E., P.LS Client � ���:�� KEF/nav � If enclosures are not as noted,kindly notify us at once 1 � � ; : � ROUTINE OPERATION AND MAINTENANCE CHECKLIST FOR PERC-RITE DRIP DISPERSAL SYSTEM Address: 31 Moss Road Date: $�2��15 HomeOwner: Lisciotti Development c/o Gregg Lisciotti Operator: Keith E. Fernandes, P.E., WWTO 4M-Full #13240 �O b .#: 1276A-W HISTORICAL DATA and CURRENT READINGS Previous flow meter reading: sssao Design flow: aao Date of last visit: a�si�a Current flow meter reading: 87590 Calculated water usage: s�9Pd Start-up dose rate Current dose rate ZONE 1: 2�03 GPM z GPM ZONE 2: ZONE 3: ZONE 4: FIELD CONDITIONS A. Drip dispersal field: visible wet spots YES❑ NO 0 Comments: B. Air release valves: erosion YES❑ NOD leakage/spraying YES❑ NO ✓❑ Comments PUMP CHAMBER/FLOAT OPERATION A. Floats match pin lights in control panel YES✓0 NO❑ COmments: See last page B. Alarm float working YES�✓ NO❑ Comments C. Solids or scum present YES� NO ✓❑ i Comments: CONTROL PANEL A. Switches in AUTO position YES ✓❑ NO❑ Comments: a I , . : , . i Ii I � B. Peak Level light on YES❑ NOD✓ � Comments: { ,' C. Power and Run lights on (microprocessor) YES❑✓ NO❑ Comments: { � PUMP and VALVE OPERATION A. Pump in HAND position: flow meter running YES ✓❑ NO❑ � Comments: B. Zones 1-4 (one at a time): flow meter running YES❑✓ NO❑ dose rate correct YES ✓❑ NO❑ � flush rate > dose rate YES�✓ NO❑ Comments: I ' C. Disc filter back flushing: working properly YES❑✓ NO❑ Comments: D. Disc filter inspection: excessive residue YES❑ NO ✓❑ cleaning required YES❑ NO� Comments: E. Switches returned to AUTO position YES❑✓ NO❑ Comments: F. RESET/CYCLE START: functionin ro erl YES ✓ NO 9P P Y ❑ ❑ Comments: G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO❑✓ Comments: SEPTIC and/or PRE-TREATMENT TANKS N/A-I/A treatment system O&M handled by others A. Examine and clean effluent filter: excessive residue YES❑ NO❑ Comments: B. Septic tank pumping recommended YES❑ NO ❑ 1. Sludge depth: 2. Scum depth: Comments: � C. Service pre-treatment system YES❑ NO❑ � Comments: Operator signature%�"—� �ticense No. �32ao Comments/Observations: Peak enabled float replaced at time of this inspection. i