1 10/15/15 Routine Operation&Maintenance Checklist For Perc-Rite Dispersal System
For review and comment: � For approval: � As Requested: � For your use: �
REMARKS:
cc:John M. O'Reilly P.E., P.LS
Client
�
���:�� KEF/nav �
If enclosures are not as noted,kindly notify us at once
1
� � ;
: �
ROUTINE OPERATION AND MAINTENANCE CHECKLIST
FOR
PERC-RITE DRIP DISPERSAL SYSTEM
Address: 31 Moss Road Date: $�2��15
HomeOwner: Lisciotti Development c/o Gregg Lisciotti
Operator: Keith E. Fernandes, P.E., WWTO 4M-Full #13240
�O b .#: 1276A-W
HISTORICAL DATA and CURRENT READINGS
Previous flow meter reading: sssao Design flow: aao Date of last visit: a�si�a
Current flow meter reading: 87590 Calculated water usage: s�9Pd
Start-up dose rate Current dose rate
ZONE 1: 2�03 GPM z GPM
ZONE 2:
ZONE 3:
ZONE 4:
FIELD CONDITIONS
A. Drip dispersal field: visible wet spots YES❑ NO 0
Comments:
B. Air release valves: erosion YES❑ NOD
leakage/spraying YES❑ NO ✓❑
Comments
PUMP CHAMBER/FLOAT OPERATION
A. Floats match pin lights in control panel YES✓0 NO❑
COmments: See last page
B. Alarm float working YES�✓ NO❑
Comments
C. Solids or scum present YES� NO ✓❑ i
Comments:
CONTROL PANEL
A. Switches in AUTO position YES ✓❑ NO❑
Comments:
a
I
, .
: , .
i
Ii
I
� B. Peak Level light on YES❑ NOD✓
� Comments:
{
,' C. Power and Run lights on (microprocessor) YES❑✓ NO❑
Comments:
{
� PUMP and VALVE OPERATION
A. Pump in HAND position: flow meter running YES ✓❑ NO❑
� Comments:
B. Zones 1-4 (one at a time): flow meter running YES❑✓ NO❑
dose rate correct YES ✓❑ NO❑
� flush rate > dose rate YES�✓ NO❑
Comments:
I
' C. Disc filter back flushing: working properly YES❑✓ NO❑
Comments:
D. Disc filter inspection: excessive residue YES❑ NO ✓❑
cleaning required YES❑ NO�
Comments:
E. Switches returned to AUTO position YES❑✓ NO❑
Comments:
F. RESET/CYCLE START: functionin ro erl YES ✓ NO
9P P Y
❑ ❑
Comments:
G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO❑✓
Comments:
SEPTIC and/or PRE-TREATMENT TANKS
N/A-I/A treatment system O&M handled by others
A. Examine and clean effluent filter: excessive residue YES❑ NO❑
Comments:
B. Septic tank pumping recommended YES❑ NO ❑
1. Sludge depth:
2. Scum depth:
Comments:
�
C. Service pre-treatment system YES❑ NO❑ �
Comments:
Operator signature%�"—� �ticense No. �32ao
Comments/Observations:
Peak enabled float replaced at time of this inspection.