Loading...
HomeMy WebLinkAbout2015 Dec 011 J.M. O'Reilly & Associates, Inc. LETTER OF Engineering&Land Surveying Services � 1573 Main Street,2nd Floor,P.O.Box 1773 TRANSMITTAL ! Brewster,MA 02631 � (508)896-6601 1 Fax(508)896-6602 TO: DATE: JOB NUMBER: Yarmouth Board of Health 12/01/2015 6699W � 1146 Route 28 South Yarmouth, MA 02664 REGARDING: 74 Pheasant Cove circle Yarmouth, Ma Shippinq Method: Regular Mail Q✓ Federal Express � Certified Mail � UPS � a Priority Mail � Pick Up � Express Mail � Hand Deliver � � COPIES DATE DESCRIPTION � 1 12/01/15 Perc-Rite Maintenance Checklist � � i i � For review and comment: � For approval: � As Requested: � For your use: � i REMARKS: cc:John M. O'Reilly P.E., P.L.S Client � 1�t�i�t: KEF/nav If enclosures are not as noted,kindly notify us at once T t �+. I � ROUTINE OPERATION AND MAINTENANCE CHECKLIST FOR PERC-RITE DRIP DISPERSAL SYSTEM Address: �4 Pheasant Cove Circle,Yarmouth Date: 11-19-15 Homeowner: Terrance& Maria Bane Operator: Keith E. Fernandes, P.E., WWTO 4M-Full #13240 lOb #: 6699W HISTORICAL DATA and CURRENT READINGS Previous flow meter reading: 5a33o Design flow: 33o Date of last visit: ��i2�n4 Current flow meter reading: sssoo Calculated water usage: 22cPo Start-up dose rate Current dose rate ZONE 1: 5�8 GPM 5�8 GPM � ZONE 2: � ZONE 3: ZONE 4: � FIELD CONDITIONS A. Drip dispersal field: visible wet spots YES❑ NO� Comments: broken pipe repaired B. Air release valves: erosion YES❑ NO� leakage/spraying YES❑ NO ✓� Comments: PUMP CHAMBER/FLOAT OPERATION A. Floats match pin lights in control panel YESD NO❑ ' Comments: B. Alarm float working YESD NO❑ Comments: C. Solids or scum present YESD NO❑ Comments CONTROL PANEL A. Switches in AUTO position YES� NO❑ Comments: , i i i i ' B. Peak Level light on YES❑ NOD ' Comments: ; C. Power and Run lights on (microprocessor) YESD NO❑ � Comments: , � PUMP and VALVE OPERATION A. Pump in HAND position: flow meter running YESD✓ NO❑ Comments: B. Zones 1-4 (one at a time): flow meter running YES ✓❑ NO❑ dose rate correct YES❑✓ NO❑ flush rate > dose rate YES❑✓ NO❑ ' Comments: C. Disc filter back flushing: working properly YES❑✓ NO❑ Comments: D. Disc filter inspection: excessive residue YES❑ NO ✓❑ cleaning required YES❑ NO� � Comments: ' E. Switches returned to AUTO position YES❑✓ NO❑ Comments: F. RESET/CYCLE START: functioning properly YES ✓❑ NO ❑ Comments: G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO❑✓ Comments: SEPTIC and/or PRE-TREATMENT TANKS � A. Examine and clean effluent filter: excessive residue YES❑ NO❑✓ ; Comments: i B. Septic tank pumping recommended YES❑ NO � 1. Sludge depth: �" 2. Scum depth: �" Comments: C. Service pre-treatment system YES❑ NO❑ Comments: N/A Operator signa ei���� License No. �32ao Comments/Observations repair to broken line in field caused by landscapers