HomeMy WebLinkAbout132 Captain Noyes Road - Septic DesignTOP OF FOUNDATION ELEV. - 102.20 ---N 10 FT. MINIMUM 4" CAST -IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4" PER FT. ELEV. - 98.0_0 ELEV. 96.47 - CONCRETE COVERS Z 4" SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FT. ' FLOW LINE 1 L%) 1\—ELEV. _ _95_22_ / F 11 LEVEL 1 BAFFSEV ELEV. = 95_87 J6' SUMIP ` ELEV. _ _95.70 DISTRIBUTION ELEV. (TO BE PLACED ON FIRM BASE) BOX-95Ja-J _ TO BE WATER TESTED 150/� 0 GALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO BE PLACED ON FIRM BASE) 3/4" TO 1 1/2" CLEAN J DOUBLE WASHED STONE FREE OF FINES & SILT SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE a CLEAN SAND INSPECTION PORT LOAM AND SEED 2" LAYER OF i/8' TO 1/2' WASHED STONE 95.9514N. PNVEONTTREQUIRED m "101 ELEV. _ _94.87 SOIL TEST DATE OF SOIL TEST NOV.12 2002__ SOIL TEST DONE BY SWEET5ER ENGINEERING WITNESSED BY B G. MURPHY OOSMVATION HOLE 1 ELEV.- 99.30 03SMVAlION HOLE 2 ELEV.- 98.70 PERCOLATION RATE _<-J2—__ MIN./INCH AT -- 56 INCHES PERCOLATION RATE -< 2_ MIN./INCH IN C HORIZON 4 HIGH CAPACITY INFILTRATORS WITH STONE IN AN z 11' X 36' X 10" TRENCH FORMATION 8.07 SOIL ABSORPTION WELL N/A NO WATER ENCOUNTERED AT —15Il- ELEV. = A6.80 ZONE SYSTEM (SAS) INDEX ADJUST DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-10 O/A LOAMY SAND 10YR3/1 NO ROOTS 10-33 B LOAMY SAND 10YR7/6 SV, 4 7 ER L GAT=v'G 235 GREAT WESTERN ROAD 508— SOUTH 0. BOX ASSN 398-3922 ,. 02660 ROOTS 33-150 C MEDIUM SAND 2.5Y8/2 DEPTH HORIZ TEXTURE COLOR MOTT. OTHER. 0-10 0/A LOAMY SAND 10YR4/1 NO ROOTS 10-31 B LOAMY SAND 10YR6/6 SV, 4 7 ER L GAT=v'G 235 GREAT WESTERN ROAD 508— SOUTH 0. BOX ASSN 398-3922 ,. 02660 ROOTS 31-132 C MEDIUM SAND 2.5Y8/2 NO WATER ENCOUNTERED AT 139" ELEV, R7 -M LEGEND: DESIGN CALCULATIONS USGS PROBABLE WATER TABLE ELEV. = EXISTING SPOT ELEVATION 00 NUMBER OF BEDROOMS _ '1 OBSERVED WATER TABLE ( / / ) ELEV. _ EXISTING CONTOUR ----00---= GARBAGE DISPOSAL UNIT NO _ BOTTOM OF TEST HOLE ELEV. _ _$5 $Q_ FINAL SPOT ELEVATION TOTAL ESTIMATED FLOW FINAL CONTOUR— QOM _J---� ( 110 GAL/9R./DAY X __1 X _ BR.) 10._ GAL./DAY SOIL TEST LOCATION REQUIRED SEPTIC TANK CAPACITY —22Q_ GAL. UTILITY POLE -•o- ACTUAL SIZE OF SEPTIC TANK - _IPP -PL GAL TOWN WATER —WSW SOIL CLASSIFICATION L_ CATCH BASIN (Im DESIGN PERCOLATION RATE !S-A— MIN./IN. GAS LINE G EFFLUENT LOADING RATE DJ -4- GAL./DAY/S.F. CLEAN OUT � LEACHING AREA 474.33 SQ. FT. CESSPOOL C.P. O (1iX36)+(47X2X70/12) OU PIXE OYES RSA TARN � J mw- loom, (Ass¢er_.V) / ✓ / 22 pO 22 p0 '��056 0 � pOM a pF �6�E1 LEACHING CAPACITY (AREA X RATE) ..Sk21,QQ GAL./DAY 474.33 X 0.74 RESERVE LEACHING CAPACITY 351QQ GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF—YA--WQQT-Ft__ RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM.SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED 04 ZON'NG REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL 'DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. - B. PARCEL IS IN FLOOD ZONE _ C 9. LOT IS SHOWN ON ASSESSORS MAP —57 AS PARCEL - 214 10. LOT IS IN A ZONE OF CONTRIBUTION TO A PUBLIC WATER SUPPLY WELL. 11. DUE TO LOT SIZE, THE SEPTIC SYSTEM IS RESTRICTED TO NO MORE THAN 110 GALLONS OF SEWAGE FLOW PER DAY. 12. A PERMANENT DEED RESTRICTION IS TO BE RECORDED AT THE REGISTRY OF DEEDS RESTRICTING THIS PROPERTY TO ONE BEDROOM ONLY. a z a CAp1A`N yMM s ^ CAP 1A�NA d05 n �{P1A�+ LOCUS PROPOSED SEPTIC DESIGN FOR ROBERT -SABER PROJECT LOCATION LOT298 132 COTATIT 110YES RD, YAR1�OUiiI SV, 4 7 ER L GAT=v'G 235 GREAT WESTERN ROAD 508— SOUTH 0. BOX ASSN 398-3922 ,. 02660 DATE NOV , 2, 2002 SCALE n = 20' JOB. NO. -557800 REV SED LOCATION 'MAP EVISED R 11.1 SHEET 1 :OF 1