Loading...
HomeMy WebLinkAbout2 Captain Small Road - Site PlanN SITE PLAN SCALE: 1 "=20' 97A'' x BENCH MARK CORNER of CONCRETE BULKHEAD, ELEV.-99.40' (ASSUMED) o.' �4{' 0 .1 . P / 1-53.51 X 9.25'W X 2.0' D leaching trench using SEVEN (7) H-20 INFILTRATOR g 0 CHAMBERRSS OR EQUAL °s 94' 7tle fp afQ�D�N �. 1?geOlt, 91.77' ry C) y m c OgR4 %• 09927 99.01. e/ab Ge �O 97Ar w3ung Houle 10' min. from *NOTE: ALL PIPES ARE TO BE 40 DIA. SCHEDULE 40 P.V.C. house to septic tank 'NOTE; INSTALL GIS BAFFLE OR EQUAL ON SEPTIC TANK OUTLET TEE. tank sews mut b �� de ebwr 2S ab w r of enbMd 9reds gra eyelem� W away FT aer.-10366' T 5 HOLE 9936' aem post CAPT' SMALL �, P� W. IMh n W. mux. 97-' C -LOT 9 AREA - 16,880± SQ.FT. 10 C�'.r+�9 Design Calculations 0a Number of Bedrooms: 3 Existing + 2 Proposed = 5 Total NaY" S ITE Garbage Grinder: NO, GRINDER NOT ALLOWED WITH THIS DESIGN Leaching Capacity Required: 550 Gal./Day p • °1t D -Y HIGH Leaching Area Required: 550 Gal./(0.74 Gal./Sq,Ft.)=743 Sq.Ft. a efteld SCHOOL L Proposed Leaching Structure: 1-53.5 X 9.25'W X 2'D Leaching Trenchour Sfo Leaching Area Provided: 745 Sq.Ft. Vila el v, TOS Proposed Leaching Capacity. 551 gpd > 550 gpd. req'd. a 9yP Re ionai 6 SSV \ TING POND GENERAL NOTES LOCUS 1. ADDRESS: #2 CAPT. SMALL ROAD 2. ASSESSORS NUMBER: MAP 78 BLOCK 130 NO SCALE 3. DEVELOPER'S LOT: LOT 9 4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM AN ON THE GROUND INSTRUMENT SURVEY. 5. TOWN WATER IS PROVIDED TO SITE & SURROUNDING PROPERTIES. 6. REFERENCE PIAN: PLAN BOOK 151 PAGE 75 7. NO WETLANDS ARE LOCATED WITHIN 150 FEET OF SAS. 8. NO POTABLE WELLS ARE LOCATED WITHIN 150 FEET OF SAS. 9. THE SUBJECT SITE IS NOT LOCATED WITHIN A GROUNDWATER ZONE OF CONTRIBUTION (ZONE II). CONSTRUCTION NOTES 1. Contractor is responsible for Digsafe notification and protection of all underground utilities and pipes. 2. The septic tank a d distribution box shall be set level on 6 of 3f4 -11/2' stone. 3. Backfill should be clean sand or gravel with no stones over 3' in size. 4. This system is subject to inspection during installation 97s7• by Glen E. Harrington, R.S. 5. The contractor shall install this system in accordance with Title V of the Massachusetts Environmental Code and the Regulations of the Town of YARMOUTH. 6. Provide an Acme Precast H-tO 5 -hole D -Box and SEVEN (7) H-20 rated infiltrator 3050's or equal. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install gas baffle or equal on septic tank outlet tee end. 9. All existing inverts and site conditions shall be verified by contractor. 10. Existing cesspools to be pumped and backfilled. �^ 11. Underground utilities located in the field per Digsafe #20044504189. 19. Fwt.f:nn Inr,nrlry rre 10 �, of dna;Iiry tr. INFILTRAT13R SYSTEMS 3050 CHAMBER TRENCH DETAIL �•-•PRO= ICE -4'11M PVC 1133ERVATI7N PORT FOR 1 / /- ESTAMMH VEGETATNE COVER W MUR E-VASNED• ' or Select FRI Ia. wmml1 W-214' PEA$TRIE-� *rale 3 SanrD SOIL EVALUATION & PERK TEST Date of Test Hole.: NOVEMBER 8, 2004 Performed By. CLEN E. HARRINGTON, R.S. Witnessed by. DAVID FLAHERTY, R.S. Excavator. D.A. BROWN LANDSCAPING PERK DEPTH: 66'-84' IN C2 RESULT: 24 GALS. APPUED IN 12 MIN. 50 SEC. Perk Rate: <2 mpi no groundwater encountered LEGEND 0 o00 x 104.46 -95- RAT EXISTING CESSPOOLS TO BE PUMPED & BACKFILLED PROPOSED 1,500 GAL H-10 SEPTIC TANK DENOTES EXISTING SPOT GRADE EXISTING CONTOUR APPROX. LOCATION EXISTING WATER LINE APPROX. LOCATION EXISTING WATER LINE 3050 Chamber End View -'sa•-+I �• Test Hole N o. 1 EP SOILS ELEV. o 1 OF 1 s Pipe Invert to m be Set 24' Above_ bw" emd Chamber Base 9' 1om1 3050 Chamber se Side View bmry .aw PROPOSED 28• 1ome/s 96.03 c PREPARED FON . S°= H HILARY TOLMAN-MICHON HA I 0 ti umiw AT ez• #2 CAPT. SMALL ROAD 0 Cc S9FGISTEQ�� ON ss4 YARMOUTH, MA 2.M/a 35 no groundwater encountered LEGEND 0 o00 x 104.46 -95- RAT EXISTING CESSPOOLS TO BE PUMPED & BACKFILLED PROPOSED 1,500 GAL H-10 SEPTIC TANK DENOTES EXISTING SPOT GRADE EXISTING CONTOUR APPROX. LOCATION EXISTING WATER LINE APPROX. LOCATION EXISTING WATER LINE 3050 Chamber End View -'sa•-+I �• BY: GEH END VO:V 2005 FILE: NOT TO Scar NDT TO SCALE 1 OF 1 Pipe Invert to m be Set 24' Above_ pr - Chamber Base 3050 Chamber Side View PROPOSED SEPTIC SYSTEM UPGRADE jN OF Mos ' p�. PREPARED FON . S°= H HILARY TOLMAN-MICHON HA I 0 ti AT .1 70 #2 CAPT. SMALL ROAD 0 S9FGISTEQ�� YARMOUTH, MA r OF 31V -111r STONE I I I LEACH TRENCH ' (art (a' Rzoutap) �� r ! Bottom of T.H. #1 Elev.-68.36• SCALE: 1 "=20' SYSTEM PROFILEno groundwater encountered s aF3/4•-11/rsTaE Not to Souls DATUM: ASSUMED PREPARED BY: GLEN E. HARRINGTON, R.S. 9 LEDA ROSE LANE MARSTONS MILLS, MA 02648 TEL: 508-428-3862 FAX: 508-428-3862 DRAWN BY: GEH I FEB. 2, 2005 FILE: RYONE -jl SHEET 1 OF 1