Loading...
HomeMy WebLinkAboutEngineered Plans - 201541 EDGE OF WETLAND > I 100' FROM tEf7 D c / i i i STA TE ,�-- _7 N�cHyyAY LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE —98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— APPROX. WATER SERVICE TEST PIT ROUTE Yarmouth Health Department 6A Dl1tnr. r - R91 I\\ 1 I II 5 F1. SOIL REMOVAL �� � j,� \ 1 TH-1 - \ \ ' EXIST. cessP � BM ¢OR TIM \ s ELEv 95.r I n9 �' \ x -PROP. 1,s'oOG- 'A SEPZIC TANK ExIST. CESSPOOL a� 1, \\ O \ \ n DIRT 0Rl►EWAY1 PAVED �� ' E OCT 14 2015 APPROXIMATE WELL LOCATION PER OWNER �/ a ' o ,—; %— r YARMOUTHPORT �a- LOCUS MAP LOCUS INFORMATION TITLE REF: BK 981 PG 283 PARCEL ID: MAP 124 PAR. 111.1 LOT SIZE: 32.88 ACRES SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 555 ROUTE 6A YARMOUTHPORT, MA PREPARED FOR CAPE COD SEPTIC SERVICES OCTOBER 5, 2015 JOHN 'N (f(OEMAREST, JI�, 140 No, 36859— MEYER. MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH: (508) 360-3311 FAX: (774) 413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SCALE: 1"=40' 1SHEET 1 OF 3 J##1747 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX EL.=96.80± OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6" OF GRADE • F.G. EL.=94.2± F.G. EL.=94.0± F.G. EL: 92.30± Rim W 9" MIN COVER/ 36" MAX COVER '' L = 55' L = 10'(MAX) ® S=19e (MIN.) 0 S=1X (MIN.) S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC INV.=92.0 j- - I '" 48" uQUID INV.=91.75 LEVEL I GAS BAFFLE \ r.....,.... ...... :. 1INV.=90.20 Im Am PROPOSED 1.500 GALLON SEPTIC TANK EXIST. SEWER OUTLET INV.=93.80 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED SEPTIC DESIGN CRITERIA tL 6ry l 11.3" TO INVERT PINV.=89.46 BOX INV.=90.0 DB - ,H2O) NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:89.85 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. F.G. EL: 92.0-91.50(MAX.) BREAKOUT=TOP ELEV.=89.85 - INV. ELEV.= 89.46 - BOTTOM ELEV.= 88.50 4' ABOVE UNSUITABLE SOILS 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (4.0'/8.7' PROVIDED) SUITABLE SOILS: EL:84.50 - ADJUSTED GW: EL:79.80 SYSTEM PROFILE NUMBER OF BEDROOMS: 4 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 4 BEDROOMS ® 110 GPD/BR = 440 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS I GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (H20) N.T.S. INSTALL TWO INSPECTION PORTS (MIN.) 4 ROWS OF 6 UNITS AT 6.25'/UNIT = 37.50'/ROW SOIL ABSORPTION SYSTEM (PROFILE) �RESTORE VEGETATIVE COVER � BACKFILL WITH CLEAN PERC SAND EXISTING SUITABLE MATERIAL USE 4 ROWS OF 6 -HIGH CAPACITY INFILTRATOR (H20) UNITS W/ ENDCAP-NO STONE TYPICAL SECTION N.LS SOIL LOGS GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. DATE: AUGUST 19, 2015 (0.74 GPD/SF) SOIL EVALUATOR: DARREN M. MEYER, RS, CSE WITNESS: AMY VONHONE, YARMOUTH HEALTH Elev. TP -1 Depth 91.501'. 0" SEPTIC TANK: 440 gpd x 200% = 880 gpd USE PROP. 1,50OG SEPTIC TANK LEACHING AREA REQUIRED: (440)/.74 = 594.59 S.F. PRIMARY S.A.S. USE 4 ROWS OF 6 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE 88 7. DWELLING IS SERVICED BY MUNICIPAL WATER. 10YR 3/1 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED BOTTOM AREA: TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE (CHAMBER) LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. OF 10. EXISTING CESSPOOLS TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5. Mi4s 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION MEDIUM 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY �,ppc1 e� G AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY rte'' 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 140 " 14. ALL PIPING TO BE 4" SCH 40 ® 1/8"/FT (UNLESS SPEC. ) 0. 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW � FOR THE USE OF A GARBAGE GRINDER. G/S1 SANITAW\a� 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. REMOVE UNSUITABLE SOILS 5 FEET AROUND LEACHING TO EL. 88.50 � OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER 1 TITLE 5. DATE: AUGUST 19, 2015 (0.74 GPD/SF) SOIL EVALUATOR: DARREN M. MEYER, RS, CSE WITNESS: AMY VONHONE, YARMOUTH HEALTH Elev. TP -1 Depth 91.501'. 0" SEPTIC TANK: 440 gpd x 200% = 880 gpd USE PROP. 1,50OG SEPTIC TANK LEACHING AREA REQUIRED: (440)/.74 = 594.59 S.F. PRIMARY S.A.S. USE 4 ROWS OF 6 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE 88 LOAMY SAND 10YR 3/1 GROUNDWATER 0 168" EL. 77.50 PERC TEST BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) WELL: SDW-252 ZONE: B 0 86.75LEVEL: (CHAMBER) 24 UNITS x 6.25 LF x 4.73 SF/LF = 709.5 SF 47.4 ADJ: 2.3 84'5C C1 MEDIUM USE ELEV. 79.80 AS ADJUSTED GROUNDWATER SAND TOTAL AREA = 709.50 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(709.50SF) = 525.03 GPD > 440 GPD req'd 73.60 LOAMY SAND 10YR 3/1 9" B LOAMY SAND 10YR 5/8 36" C1 MEDIUM SAND 2.5Y 7/3 96.. C2 SILT LOAM 10YR 4/2 173" PERC RATE <2 MIN/IN. (*Cl" HORIZON) • I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that' I have passed the Soil Evol. Exam in October, 1999. SECTION 11" H r END CAP INFILTRATOR - HI CAPACITY (H2O) CHAMBER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 555 ROUTE 6A, YARMOUTHPORT, MA Prepared for: Cape Cod Septic Services System Design and Site Plan by: SCALE DRAWN DATE MEYER& SONS, INC. N.T.S. DMM 10/05/15 PO BOX 961 EASTSANDW/CH, MA 02537 CHECKED SHEET NO. 508-3622922 DMM 3 of 3