Loading...
HomeMy WebLinkAbout23 Carriage Lane - Site Plan 2LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 0-100-o PROPOSED CONTOUR 100 EXISTING CONTOUR w PROPOSED WATER SERVICE G PROPOSED NATURAL GAS SERVICE CATV -PROPOSED CABLE SERVICE T&E PROPOSED TELEPHONE AND ELECTRIC SERVICE AD PROPOSED AREA DRAIN BP PROPOSED BACKWASH PIT PROPOSED LAMP BENCHMARK: HYDRANT TAG BOLT 1008 EL=70.76' VARIANCES TOWN OF YARMOUTH HEALTH REGULATION 3.7 - FOUNDATIONS OF DWELLINGS SHALL NOT BE LESS THAN TWO FEET ABOVE THE HIGHEST POINT IN THE ROAD: FROM 2' ABOVE TO 2.04' BELOW (4.04') OFeP/ G i POINT IN ROAD 70.04' ,, jG i i S �V V �• �L z G �h c° G w-_ w_ ,0 / I " r�F HANDS%. \ r&F c T& c F TEL RISERS G X70 T&F \ ELEC METER ALL GATES TO OPEN OUTWARD AND BE SELF-CLOSING WITH LATCH ON INSIDE. SOLID WOOD FENCE AS PER BUILDING CODE. DOORS TO BE ALARMED. SWALE ST0NF *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM s9 SYSTEM PROFILE �9 TOP FNDN. AT EL. 68.0' ACCESS COVERS TO WITHIN 6' OF FIN. GRADE (NOT 70 SCALE) ACCESS COVER TO WITHIN 3" OF FIN. GRADE /-- ACCESS COVER (WATERTIGHT) TO /F6-6-.5-7± MINIMUM .75' OF COVER OVER PRECAST // WAIN 6' OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM I 65.0'± II *62.58' PROPOSED 1500 GALLON SEPTIC 62.30' TANK (H- 20 ) 1 DEPTH OF FLOW 4' H-10 SEPTIC TANK �CO PACTION. (15.2210[21))ECHANICAL TEE SIZES: H-20 DBOX INLET DEPTH = 0_ OUTLET DEPTH 14" (_2.5% SLOPE) FOUNDATION- 11 - SEPTIC TANK DCE #07-049 (-.L% SLOPE) 55' - PIPE LEVEL FIRST 2' 2" DOUBLE WASHED PEASTONE OR GEOTEXTILE FABRIC Ve- )PAVED LAWNARE DRIVEWAY C5 AROpOSFO ADO G ZONING SUMMARY ZONING DISTRICT. R-40 DISTRICT MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' SHAPE FACTOR 22 MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20' MIN. REAR SETBACK 20' MAX. BUILDING HEIGHT 35' MAX. BUILDING COVERAGE NOT TO EXCEED 25% FS PROPOSED: 9.7% 4 PROVIDE VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT WITH HOMEOWNER CONSULTATION) TREE LINE NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR PROPOSED PRECAST DBOX & LEACH CHAMBERS TO BE AASHO H-20, SEPTIC TANK TO BE H-20. 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM.TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. COORDINATE ALL UTILITY INSTALLATION WITH PERMITTING AUTHORITIES AND APPROPRIATE VENDORS. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 5 BEDROOMS 0 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD (2) = 1100 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (42 + 12.83) 2 (.74) = 162 GPD BOTTOM 42 x 12.83 (.74) = 398 GPD TOTAL: 756 S.F. - -560 GPD USE (4) H-20 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE MA BOARD OF HEALTH LOCUS MAP SCALE: 1" = 2,000'± ASSESSORS MAP 112 PARCEL 48 LOCUS IS NOT WITHIN APD (ZONE II) TEST HOLE LOGS ENGINEER: A. H. OJALA, PE WITNESS: PHIL RENAUD, YBOH DATE: MARCH 29, 2007 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# p" 4 ELEV. 63.5' p" Rte 6A O a ELEV. 62.7' Locus Sand Ff ya Corrin e o Dennis Pond z� a 0 m� J Exit 7 Route 6 1OYR 3/3 3" LOCUS MAP SCALE: 1" = 2,000'± ASSESSORS MAP 112 PARCEL 48 LOCUS IS NOT WITHIN APD (ZONE II) TEST HOLE LOGS ENGINEER: A. H. OJALA, PE WITNESS: PHIL RENAUD, YBOH DATE: MARCH 29, 2007 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# p" 4 ELEV. 63.5' p" ELEV. 62.7' 0/A O/A 31, 1OYR 3/3 3" 1OYR 3/3 E E FS FS 4 1OYR 7/1 4 1OYR 7/1 B B LS LS 14" 1OYR 4/4 62.3' 14" 10YR 4/4 61.5' C C PERC MCS MCS 120" 10YR 6/6 53.5' 120" lOYR 6/6 52.7' NO GROUNDWATER ENCOUNTERED LOT 17 N TITLE 5 SITE PLAIm 49,593 SFf ; of 67 t (SEE VENT NOTE ON PLAN) UNDISTURBED PROPOSED POOL FILTER SHED (80 S.F.) 23 CARRIAGE LANE �£9 YARMOUTH (PORT), MA PREPARED FOR PETER TROUTMAN 62.0' \ DATE: JANUARY 23, 2008 C7 0 E7 O O n o 0 o ALL SYSTEM COMPONENTS SHALL BE REV. DATE: JANUARY 28, 2008 (SHED, D.W.) 61.0' Q 0 Q = p E� p E3 p � MARKED WITH MAGNETIC TAPE OR "=20' E7 ED = 17711771o E7 0 0 o COMPARABLE MEANS FOR FUTURE LOCATION. Scale:l 59 2 O E7 E7 O 0 0 O 7-O o 59.0' 3/4" TO 1 1/2" DOUBLE WASHED STONE 0 10 zo 30 40 5 FEET f" ` e" p; (4) H-20 500 GALLON CHAMBERS log 1HOPdC LWT TOAIL TNR (--L-% SLOPE) EYCRWS AND!70 To_ -_ 35' LEACHING 6.3',67 2%/0f off 508-362-4541 FACILITY YARlMM WATER DEPT DATE fax 508 362-9880 2�SNOFF jA o$-� ROFM BOTTOM TH-2 EL. 52.7' DATE DANIEL A. OJALA, P.E., P.L.S. do wn cape engineering, in c. Cl VIL ENGINEERS LAND SURVEYORS 939 Main Street - YARMOUTHPORT, MASS. 07-049 TROUTMAN.DWG (DD