HomeMy WebLinkAbout23 Carriage Lane - Site Plan 3LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 0--100—o PROPOSED CONTOUR — 100 EXISTING CONTOUR w PROPOSED WATER SERVICE G PROPOSED NATURAL GAS SERVICE CATV PROPOSED CABLE SERVICE T&E PROPOSED TELEPHONE AND ELECTRIC SERVICE AD PROPOSED AREA DRAIN BP PROPOSED BACKWASH PIT PROPOSED LAMP BENCHMARK: HYDRANT TAG BOLT 1008 EL= 70.76' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM TOP FNDN. AT EL. 68.0' VARIANCES TOWN OF YARMOUTH HEALTH REGULATION 3.7 - FOUNDATIONS OF DWELLINGS SHALL NOT BE LESS THAN TWO FEET ABOVE THE HIGHEST POINT IN THE ROAD: FROM 2' ABOVE TO 2.04' BELOW (4.04') ALL GATES TO OPEN OUTWARD AND BE SELF-CLOSING WITH LATCH ON INSIDE. SOLID WOOD FENCE AS PER BUILDING CODE. DOORS TO BE ALARMED. SYSTEM PROFILE 1'� ACCESS COVERS TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) � ACCESS COVER (WATERTIGHT) TO / ACCESS COVER TO WITHIN 3" OF FIN. GRADE WITHIN 6. OF FIN. GRADE - I / *62.58' 62.3D'Ila- 58' SUMP ,LE 61.5' ` DEPTH OF FLOW 4' �6' CRUSHED STONE OR MECHANICAL H-10 SEPTIC TANK COMPACTION. (15.221 [21) TEE SIZES: H-20 DBOX INLET DEPTH = 1� OUTLET DEPTH = 14" (_2.5% SLOPE) FOUNDATION— 11' — SEPTIC TANK DCE ##07-049 (_L% % SLOPE) — 55' — PIPE LEVEL FIRST 2' OliGEOTEXTILE FABRIC (SEE VENT NOTE ON PLAN) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 59.0' BOTTOM TH-2 EL. 52.7' ZONING SUMMARY ZONING DISTRICT. R-40 DISTRICT MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' SHAPE FACTOR 22 0 61.0' O000 30' O 1=11=11=1 SIDE SETBACK 20' 71 o REAR SETBACK 20' MAX. ooaa 35' o 0000 BUILDING COVERAGE NOT TO EXCEED 25% 2' ED o a 000a 3/4" TO 1 1/2" DOUBLE WASHED STONE (4) H-20 500 GALLON CHAMBERS (—L—% SLOPE) D' BOX 35' LEACHING FACI LIN (SEE VENT NOTE ON PLAN) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 59.0' BOTTOM TH-2 EL. 52.7' ZONING SUMMARY ZONING DISTRICT. R-40 DISTRICT MIN. LOT SIZE 40,000 S.F. MIN. LOT FRONTAGE 150' SHAPE FACTOR 22 MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20' MIN. REAR SETBACK 20' MAX. BUILDING HEIGHT 35' MAX. BUILDING COVERAGE NOT TO EXCEED 25% PROPOSED: 9.7% PROVIDE VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT WITH HOMEOWNER CONSULTATION) NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR PROPOSED PRECAST DBOX & LEACH CHAMBERS TO BE AASHO H-20, SEPTIC TANK TO BE H-20. 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. COORDINATE ALL UTILITY INSTALLATION WITH PERMITTING AUTHORITIES AND APPROPRIATE VENDORS. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW. 5 BEDROOMS ® 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD (2) = 1100 USE A 1500 GAL SEPTIC TANK LEACHING: SIDES: 2 (42 + 12.83) 2 (.74) = 162 GPD BOTTOM 42 x 12.83 (.74) = 398 GPD TOTAL: 756 S.F. 560 GPD USE (4) H-20 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4 STONE ALL AROUND APPROVED LOCUS MAP SCALE: 1" = 2,000'± ASSESSORS MAP 112 PARCEL 48 LOCUS IS NOT WITHIN APD (ZONE II) TEST HOLE LOGS ENGINEER: A. H. OJALA, PE WITNESS: PHIL RENAUD, YBOH DATE: MARCH 29, 2007 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS P# Q ELEV. F� p" r —� 63.5' p„ v 0/A 3 1OYR 3/3 E FS 4" 1OYR 7/1 B LS 14" 1OYR 4/4 62.3' PERC C MCS ELEV. 62_7' 0/A 3" 1OYR 3/3 E FS 4 1OYR 7/1 B LS 14" 1OYR 4/4 61.5' C MCS MA 1OYR 6/6 / DATE BOARD OF HEALTH 120" 1 1 53_5' 120" tOYR 6 6 52_7, NO GROUNDWATER ENCOUNTERED flu tov DATE DANIEL A. OJALA, P.E., P.L.S. 4' rrs m C �I i — TITLE 5 SIT E PLA OF 23 CARRIAGE LANE YARMOUTH (PORT), MA PREPARED FOR PETER TROUTMAN DATE: JANUARY 23, 2008 REV. DATE: JANUARY 28, 2008 (SHED, D.W.) Scale:1 "= 20' 0 10 20 30 40 50 off 508 -362 - fox 508 362 -APPROVED JAI N 312901 YARMOUTH 4 LD KING'S HIGHWAY RECEIVED IVED own cope engineering, iZoos C Cl VIL ENGINEERS YARMOUTH LAND SURVEYORS OLD KING'S HIGHWP" 939 Main Street YARMOU THPOR T, MASS. 07-049 TROUTMAN.DWG (DDF) Rte 6A O Qc Locus Sand ' �F �J Como e O Dennis Pond x� a 0 m J � g m Exit 7 Route 6 LOCUS MAP SCALE: 1" = 2,000'± ASSESSORS MAP 112 PARCEL 48 LOCUS IS NOT WITHIN APD (ZONE II) TEST HOLE LOGS ENGINEER: A. H. OJALA, PE WITNESS: PHIL RENAUD, YBOH DATE: MARCH 29, 2007 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS P# Q ELEV. F� p" r —� 63.5' p„ v 0/A 3 1OYR 3/3 E FS 4" 1OYR 7/1 B LS 14" 1OYR 4/4 62.3' PERC C MCS ELEV. 62_7' 0/A 3" 1OYR 3/3 E FS 4 1OYR 7/1 B LS 14" 1OYR 4/4 61.5' C MCS MA 1OYR 6/6 / DATE BOARD OF HEALTH 120" 1 1 53_5' 120" tOYR 6 6 52_7, NO GROUNDWATER ENCOUNTERED flu tov DATE DANIEL A. OJALA, P.E., P.L.S. 4' rrs m C �I i — TITLE 5 SIT E PLA OF 23 CARRIAGE LANE YARMOUTH (PORT), MA PREPARED FOR PETER TROUTMAN DATE: JANUARY 23, 2008 REV. DATE: JANUARY 28, 2008 (SHED, D.W.) Scale:1 "= 20' 0 10 20 30 40 50 off 508 -362 - fox 508 362 -APPROVED JAI N 312901 YARMOUTH 4 LD KING'S HIGHWAY RECEIVED IVED own cope engineering, iZoos C Cl VIL ENGINEERS YARMOUTH LAND SURVEYORS OLD KING'S HIGHWP" 939 Main Street YARMOU THPOR T, MASS. 07-049 TROUTMAN.DWG (DDF)