HomeMy WebLinkAbout54 Cedar Street - Septic DesignY a BM' 1 S ST TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR SOIL &1Y 11 DATE Of SOIL TEST $lL�1t 2QQL__- 100.00_ 10 FT. MINIMUM 10 FT. MINIMUM FROM SIB OR CRAWL SPACE SOIL TEST DONE BY SWFFTSFR c ELEV. _ CLEAN SAND -- -- d0EE@1ClG (ASSUMED) CONCRETE WITNESSED BY A, VON HONE COVERS a LOAM AND SEED OBSERVATION HOLE 1 ELEV.- 98.10 4" SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FL 2' LAYER OF PERCOLATION RATE < 2 MIN./INCH AT 36 INCHES 1/8" TO 1/2" LEGEND: DEPTH HORIZ TEXTURE COLOR MOTT• OTHER 99.73 MAX. w.+SHED STONE VENT EXISTING SPOT ELEVATION 00„0 �(- 0-0 ' Ap LOAMY SAND 10YR2/2 NO 2.90 (O CAST IRON PIPE L (OR EQUAL) MINIMUM �7•� �N• NOT REQUIRED EXISTING CONTOUR ----00---- ���►555- PITCH 1/4" PER FT. 3 1 CU. FT. OF FINAL SPOT ELEVATION B-30 8 LOAMY SAND 10YR5/8 CONCRETE FINAL CONTOUR ANCHOR SOIL TEST LOCATION Q 30-11 Cl MEDIUM SANG 2.5Y6/3 RAISE PIPING FLOW LINE 95.73 ° UTILITY POLE -O (IF NECESSARY) ELEV. s AL10 Lj 10" TOWN WATER =WSW MIN. ELEV. = 9B• 2 0" o o _ ° o CATCH BASIN to LEVEL o _ 0 10• ELEV. 95'40 GAS LINE ELEV. s _4�� GAS ELEV. _ �Q SO 6" SUMP ELEV. _ �� CLEAN OUT C BAFFLE .DISTRIBUTION CESSPOOL C.P. O LIQUID OUTLET ELEV. m ._... 4 HIGH CAPACITY INFILTRATORS WITH DEPTH TFF (TO BE PLACED ON FIRM BASE) BOX _RL2 STONE IN AN 5.00 4 FEET 14 INCHES TO BE WATER TESTED 11' X 34' X 100 TRENCH FOFMATION 5 FEET 19 INCHES IF MORE THAN ONE OUTLET 6 FEET 24 INCHES 1500 GALLON1 10 7 FEET 29 INCHES (TO BE PLACED ON FIRM BASE) SOIL ABSORPTION WELL M1W 29 WATER ENCOUNTERED AT �tOB" ELEV. a 69 11] 8 FEET 34 INCHES SEPTIC TANK '/ ZONE A 3/4" TO 1 1/2" CLEAN STEM (SAS) INDEX 7.6 DOUBLE WASHED STONE ADJUSTI.3 FREE OF FINES Ec SILT DESIGN CALCULA'T'IONS USGS PROBABLE WATER TABLE ELEV. _ _90.4Q_ NUMBER OF, BEDROOMS _3__ SEWAGE DISPOSAL SYSTEM PROFILE OBSERVED WATER TABLE (7/11/1001) ELEV. _ _fl91Q_ GARBAGE DISPOSAL UNIT No NOT TO SCALE BOTTOM OF TEST HOLE ELEV. _ -8172- TOTAL ESTIMATED FLOW ( 110 GAL/BR./bAY X 3 BR.) _M0_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY __flFQ_ GAL. ACTUAL SIZE OF SEPTIC TANK _1.S00 GAL. SOIL CLASSIFICATION I DESIGN PERCOLATION RATE "-- MIN./IN. EFFLUENT LOADING RATE x.74_ GAL./DAY/S.F. LEACHING AREA 412M SQ. FT. (11X34)F(45X2X10/12) LEACHING CAPACITY (AREA X RATE) A= GAL./DAY 449.00 X 0.74 RESERVE LEACHING CAPACITY NONE GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E,P, TITLE 5 AND THE TOWN OF __1YA8M0AffiL_ RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN p \ a fy C 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE �Y w USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. f 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL x 97.3 _. - - cE MORTARED iN PLACE. 5. NO CE 7RMINATION HAS BEEN MADE AS 10 COMPLIANCE WITH 1D0.0�" DEEDED OR ZONING REGULATIONS, OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. W LOT 246 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR X 98.2 4" -_ 9, 395 SQ. FT. IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. - 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS 19 0 \ SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER D. BOX PR OSED N \ IMMEDIATELY. 5, SOIL N AD o 8. PARCEL IS -IN. -FLOOD -ZONE ._ B JEST q SLAB) $ 9. LOT IS SHOWN ON ASSESSORS MAP 34 AS PARCEL 132 1500 GALLON 10. EXISTING CESSPOOLS ARE TO BE PUMPED AND REMOVED. SEPTIC TANK z PORCH .1 \ 11. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR L x 8.7 ' A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED z o, 20.09 - WITH SAND AS SPECIFIED IN 310 CMR 15.255:(3). % OF Lk - 12. VARIANCES 'TO TITLE 5 AND YARMOUTH REGULATIONS: A. SOIL ABSORPTION SYSTEM LESS THAN 10' FROM LOT UNE. EXISTING DWELLING T A S. NO RESERVE AREA. .0 3 BEDROOMS �' o DUMAS lw U 98.4 98.5:. " BQl1 APPROVED: BOARD OF HEALTH X 9E.4 98.8 / x 97.7 W15.4T 8.i 8.7 x �i,g?/ y DATE AGENT x-so.a CL U H r-\ 0 2001 SWEETSER ENGINEERING oJ�ti� MPWN 5 j �` WILLOW zo a DA Locus___ . BRA ALDE PROPOSED SEPTIC DESIGN FOR DONALD THOMAS PROJECT LOCATION IDT 246 154 CEDAR STREET, YARMOUTH S iEMSER ENGINEERD�G 235 GREAT WESTERN ROAD 508-, P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE JULY 13, 2001 SCALE 1 = 20 REV. DEC. 10, 2001 108 NO. 5165-00 LOCATION MAP REvsED SHEET 1 OF�1 0 2001 SWEETSER ENGINEERING