Loading...
HomeMy WebLinkAbout132.130 - Title 5 Site Plan(IN AREA OF PIPE EXIT) PRECAST/ �H-10 RISERS (TYp.) 2'0 *21.8'± (PROP.) 21.38' ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 25.0' MINIMUM .75' OF COVER OVER PRFr.A4 10" 1500 GAL H-10 14" TEE SEPTIC TANK TEE GAS BAF (NOT TO SCALE) FOR CARRIAGE HOUSE/GARAGE BLDG. ONLY 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE WATER -TEST D'BOX FOR LEVELNESS PROP. TEE O 4 0PVC PIPEESS LLEE VEL 1ST 2' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE. REQUIRED OVER SYSTEM 22.0' BLOCKS OR MORTAR ALL PRECAST RISERS COMPONENTS H-10 (TYPENDS I SIDES 19.23' A 'Rod 4' UQ. LEVEL (ACME OR EQUAL)j'. 18.66' 18.49' ° 16.4 JPO"O"O�OpO"O�O�OQO"ODOR""OpOpOQOQO"O�O000- pL !I �"S�,","g"000"gags°oge�etnffl0000P `H-10 500 GiL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 22.0' X 8,83 4.4' COMPACTION. (15.221 [21) (-2-% SLOPE) (14,77 SLOPE) (-L-% SLOPE) FOUNDATION- 21' SEPTIC TANK 23' D' BOX 11' LEACHING FACILITY 120' BOTTOM TH-1 *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM NOTE: BUILDING SEWER TO EXIT IN AREA SHOWN, AT MIN. ELEVATION SHOWN LEGEND TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE WITNESS: PHIL RENAUD DATE: 4/15/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. 1 0" 22.0' - A LS 1OYR 3/2 19" B LS 1OYR 5/8 43" 18.4' PERC C MS 1OYR 7/4 120" I 112.0' NO GROUNDWATER ENCOUNTERED 14-061 X25.74 X 21.38 X yry61- CHERRY „CHERRY 23\ X23.47 --y�{�L((L✓� 37.6 4 _ 21.87 GARDEN X 20 1 3 � -- 7�;aQ.44 0.97.._ _. X21. 0 X 20.700 ? �g21.33. X21.25 \�� \ � 21.133 X 23.46 CB END NO GROUNDWATER FOUND S3' LOT AREA: 22,571± SF NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. I 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL 8E RESPONSIBLE FOR LAmniw wINIUVK X BB.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 99 v `m ti Locus PROPOSED SPOT EL. TH1 0 TEST HOLE 2Z; SLOPE OF GROUND a UTILITY POLE y % FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE WITNESS: PHIL RENAUD DATE: 4/15/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. 1 0" 22.0' - A LS 1OYR 3/2 19" B LS 1OYR 5/8 43" 18.4' PERC C MS 1OYR 7/4 120" I 112.0' NO GROUNDWATER ENCOUNTERED 14-061 X25.74 X 21.38 X yry61- CHERRY „CHERRY 23\ X23.47 --y�{�L((L✓� 37.6 4 _ 21.87 GARDEN X 20 1 3 � -- 7�;aQ.44 0.97.._ _. X21. 0 X 20.700 ? �g21.33. X21.25 \�� \ � 21.133 X 23.46 CB END NO GROUNDWATER FOUND S3' LOT AREA: 22,571± SF NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. I 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL 8E RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF NOT TO SCALE WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED ASSESSORS MAP 132 PARCEL 130 SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 9 N EXISTING SEPTIC SYSTEM FOR HOUSE - -' INSTALLED 1993 (RETAIN) r,? 22.70 1 O 3.3 z�.70 TWIN MAPLES -��\/r / 22.94 O O LP a (TO BE SLAB 3. O REMOVED) EXIST. 23.92 / 11 X 23.57 CARRIAGE HOUSE/GAR. X/.73 70 14 2 70 6 �X 2 .56 (PROP. 1 BR) 24 8 4.11 4.1 s / - 3.7 24.26 4.22 EXISL.DWELLING 23.36 3 25.70 PROP. RO WATERL'N 24.46 4 458 4.61 4.72 . gas 3 24.33 4.74 meter GASCI 25.46 4.75 Nf yC.�A.60 24.70 4.87 -X 25.35 GRAVEL (V� \ DRIVEWAY \ y. BENCHMARK: /44>> X24.55 DOORSILL HERE AT ELEV. 25.T \ X2725.50 \�fC 94 5 Scale: 1 "= 20' 0 10 20 30 40 50 FEET WORK MUST C FORM TO ALL TOWN R LAREGULATIO S YARMO TH)NATER DEPT DATE 52 AN -: A r /, e/veae� U.1 A � a v `m ti Locus 0 t a o 2 'N CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF NOT TO SCALE WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED ASSESSORS MAP 132 PARCEL 130 SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 9 N EXISTING SEPTIC SYSTEM FOR HOUSE - -' INSTALLED 1993 (RETAIN) r,? 22.70 1 O 3.3 z�.70 TWIN MAPLES -��\/r / 22.94 O O LP a (TO BE SLAB 3. O REMOVED) EXIST. 23.92 / 11 X 23.57 CARRIAGE HOUSE/GAR. X/.73 70 14 2 70 6 �X 2 .56 (PROP. 1 BR) 24 8 4.11 4.1 s / - 3.7 24.26 4.22 EXISL.DWELLING 23.36 3 25.70 PROP. RO WATERL'N 24.46 4 458 4.61 4.72 . gas 3 24.33 4.74 meter GASCI 25.46 4.75 Nf yC.�A.60 24.70 4.87 -X 25.35 GRAVEL (V� \ DRIVEWAY \ y. BENCHMARK: /44>> X24.55 DOORSILL HERE AT ELEV. 25.T \ X2725.50 \�fC 94 5 Scale: 1 "= 20' 0 10 20 30 40 50 FEET WORK MUST C FORM TO ALL TOWN R LAREGULATIO S YARMO TH)NATER DEPT DATE 52 AN -: A r /, D` .IE L U.1 A Clan 0 eW FSC , STE�i1 \� �•r c r�"^ 41 DATE DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED PROPOSED 1 BR IN EXIST. CARRIAGE HOUSE/GARAGE DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (22 + 8.83) 2 (.74) = 91 GPD BOTTOM 22 x 8.83 (.74) = 143 GPD TOTAL: 317 S.F. 234 GPD USE (2),500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2.5' STONE AT ENDS AND 2' AT SIDES �;>� Feai#; G I�e�s;;rta 1ert a ED alne Date MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 41 CENTER STREET YARMOUTH PORT PREPARED FOR JACK HANNON APRIL 17, 2014 REV. MAY 5, 2014 (ELEV.) l off 508-362-4541 fax 508-362-9880 downcope.com down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675