Loading...
HomeMy WebLinkAbout236 Center Street - Site & Septic Planr14.8 \\ 2 _11,9.9e9 Vegetated Wetland --i i52 Bor p - ` Vegetated � ga denr+g 0 c° @ L 27p-23' h� do 2onehPr \ .17. 0 17.4_ 18 - 70 r \. ' 185 \ x 9 \ \ 192 20.0_._ O•e Zo x1.2 2,L 41 \ " 197 21.4 x 2 \ .0 N x 18.6 't. x 21.8 R�22:1 LOT 7 _ Area= 79,840 SF -t , \ 22.5 . - - 19.4 ,Z � \ ,r X 21.9 z 19.4 1" ` � 22.9' � IC E x 2d2 16 2.80 _ 201 x NQ -- 198 . / g0 r' - 2.57 22i\ o t }O�1 - 1 + _ 1.O�dg i 2.36 I '1 N / 1.95 x'd,9 x 22.7 -2013 R / 2.75 p1t i "ZU_' -:.. - 1.2 2 _. 3.08 x 22.4 2D.4 Ifc �Isl �/ ( 7* 202 104 r� C�t3�,� f['! 20.7 ��i`'L� j � - x 225 I. N I �....N - l I - a 0.72 ? a 1.88 ) 1.76 2\ c0 '�-•.� ;; „ zo.2x-ear - ''tt�.11..YY 2.14\ 2 jt 20.8 x 21.7 I I �2o.e z 22.0 2C3 .: Z p�:i #3V 20� -Y� -'2.03 21.8cl \ + 20.5 0.17 f e 5 ' 0'4PROPOSEF) WATER 20.4 / w w- W w -I w .7 / _ - 19.6 +I } 198 x 272 /rr TOP OF FOL .D 10:' x18,5 - - 19.8'�x 8 I"1 `'�--..:.�, ExisHn3 323 5.F I Bedroom Cettae /g \ �,19. TO BE DEMOL15tD I A YRB (FNp) ' (3m +19 18 - 7P Y+ _ x 18.3 �. -PROPOSED TIC -H 7A. Appror. Location of / 4 (o (2000 GALLON l'4.) existing Septic ,� 17.63 x .6 Y ` �e� --- - Serwng / t91� - um 17.9 Arproximate Lcc.on Main House TO _ of Fx15tm6j Ce- 51" A r I - ! m ;:^�l^t ° 'x 18.1 _ (SEE NOTE N7) Apr" yam __ la 1 166 x 170 FLOW PROFILE: 16,9 NOT TO SCALE 6 /° x '6 TOP OF FOUNDATION \% 116ro 16.0 --1 EL=22.0- ;i 164 '.1 7.0 x I O ?6 s 0154 - x 1 O f �Lts'� DEPTH FROM SURFACE (INCHES) 501L HORIZON 501L TEXTURE (U5DA) 501L COLOR - (MUN5ELL) 501L OTHER - MOTTLING 0-1 2' A LOAMY 5AND I CYR 3/3 _ NONE 12-3 1' B SANDY LOAM I OYR 8 NONE_ 31-72' CI 15ILT LOAM 101'R 4 NONE 72-165" C2 BLUE CLAY I OYR GLEY 14 G- I NON= LOCU5 S^ �E TEST HOLE 2: EL= 19.6± m 3 DEPTH FROM SOIL SOIL SOIL SOIL OTHER SURFACE HORIZON TEXTURE COLOR MOTTLING (INCHES) (U5DA) - - (MUN5ELL) 0-14" A LOAMY SAND IOYR 3/4' NONE 14-48" B LOAMY SAND I OYR 5/8 _ NONE 48-150' Cl SILT LOAM I CYR 5/2 20% .5 YR 5185 48" 150-195' C2 MEQUIWEINE SAND I OYK 7/3 NONE Homers Dock 3 a Lookout N l TEST HOLE 3: EL=20.0+ DEPTH FROM SOILSOIL - SOIL' SOIL OTHER SURFACE HORIZON TEXTURE - COLOR MOTTUNG (INCHE5) (USDA).. - (MUN5ELL) -.:. O-1 G' A - LOAMY SAND I OYR 3/4 NONE 16146' B LOAMY SAND - IOYR 518 NONE 46-1 20' CI I MEDIUMEINE SAND I OYIZ 713 1203. .5 YK 5/5) 48" NOT TO SCALE LAND COURT PLAN 1 5849-E CERTIFICATE # 1 9GO94 3 : x 1 :'FLOAT INSTALLATION NOTES:. 15 15.2 / Vehcl, ;racks (.)FLOAT SHALL BE INSTALLED WITH ACABLE WEIGHT M _ `'�xs'1FL'I sting - 2.) FLOAT SHALL BE INSTALLED 50 THAT THEY CAN BE x A ACCESSED FROM OUTLET MANHOLE COVER \G 3.) FLOAT MUST BE INSTALLED 50 THAT IT IS .I 1 OUTLET SHALL BE SEALED 15 15��-!, - .5 .- /-PRCPl7iED ROPT (SEE MOTES) _ %� r7' / FREE TO MOVE THROUGHOUT ITS TRAVEL 19.0± _ � 17.63 ON at 3/5 Capacity GROU (1373 Gal.) 4'-3' EL- G.0- YRB (TND 4 1'- 2'_6' HF;H -NDWATFR BASED ON MOTTLING .Tim Sherry N o m e s - 1q 13.6 - 14.4 BUOYANCY CALCULATIONS: 3 ° P.O. Box 1 69, East Dennis, Ma 02G41 13.5 F. r ... + a (.Ils I'` .,:+ ,m .,, JR I g0, P P f 2000 GALLON MONO SEPTIC TANK a E 1a9� 1304 / PROPOSED SITE SEPTIC SKETCf1 PLAN ,q t J S 236 Center Street, Yarmouthport, Ma N d 14,3 Fel=(1 .234118'X3.C)62:?LE/CF S• G-1 a JIM. �1REILLY $C ASSOCIATES INC. - 16,294 lbs 2000 GALLON MONO -, - S l_TANK 17,853 MIGHT TIGHT TANK S^�v 1j CB (TND) Fw = 17,853 IIs. (Per. Spec) c orc. ) Professional Engineering & Land Surveying Services BENCHMARK: F\.+1= 17,853 lbs > FBI= 16,293 lbs i "'- - _- - --` g g m o � Top of Concrete Bound U5E 5T -20C MONO 5EMC TANK BY 5HOREYP,ECA5T CONCRETE PRODUCTS N - EI =22.8± (1988 NAVDj (Based On High 7 �� �. ,,{t/� pn p� eQi4.3 �T WOR[ MUST CONFO O ALL UP#43/40 Groundwater EL=16.0) �J% /�/" 0 3O GO 90 1573 Main Street - Route BA P.O. Hos 1773 2p p p - (508)896-6801 `Office Brewster, MA 02631 (508)896-6602 Fax T - j 1\I U L#WS CX REGULArTIONS SCALE I"=3O'.. DATE: SCALE: BY: CHECK: JOB NUMBER: G:Wl1ot\Tlm5herryHomes\23GCenter5treet\7030TIGHT TANK.DWG 2/ 1 O/ 1 5 A5 Noted AFM KEF SMO -7030 saw �� r�i ri, rernTrR flCr]T f1 ATC - ASSESSORS' MAP 140 PARCEL 45 DATE OF TESTING: 12/12/14 - WITNESSED BY: KEITH E. FERNANDE5, PE, J.M. O'REILLY t ASSOCIATES, INC. ,'YARMOUTH HLTP DEPARTMENT AMY Von HONE, A5515TANT HEALTH DIREC`TORfA ESTIMATED 5EA50NAL HIGHGROUNDWATER BASED ON ELEVATION OF MOTTLING IN TEST PIT #3 (EL= I G -0-t) LEGEND uffer.. -F 32 EXISTING CONTOUR e GENERAL NOTES: 32 PROPOSED CONTOUR xr2.34 EXISTING SPOT GRADE 24x5 PROPOSED SPOT GRADE A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER TIGHT TANK cs (TND) _w_ WATER SERVICE LINE It22.6 UNLE55 H-20 COMPONENTS ARE USED. B.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UN- -E- UNDERGROUND. ELECTRIC LINE - LF55 CONSTRUCTED AS SHOWN ANYCHANGE5 SHALL BE APPROVED IN WRITING. - -'-U- - UNDERGROUND UTILITY SERVICE C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERJFYING THE LOCATION OF ALL GAS SERVICE LINE.' UNDERGROUND AND OVERHEAD UTILITIES PRIORTO COMMENCEMENT Of WORK. TEST HOLE /BORING LOCATION CONSTRUCTION NOTES: TT PROPOSED TIGHT TANK CO UTILITY POLE ® CATCH BASIN 1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, - 100 FIRE HYDRANT TIME 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH. ® WELL 2-) TIGHT TANK SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS BEEN ® DRAINAGE MANHOLE MECHANICAL LY COMPACTED, OR ON A G INCH CRUSHED STONE BASE. CONCRETE BOUND, FOUND 3.) THE BOARD OF HEALTH SHALL REQUIRE INSPECTION OF ALL CONSTRUCTION -- TOP OF BANK BY AN AGENT OF THE BOARD OF HEALTH (OR THE DESIGNER IF THI5 SYSTEM RE- QUIRES A VARIANCE) AND MAY REQUIRE SUCH PERSON TO CERTIFY IN WRITING iL -x-z- LIMIT OF WORK THAT ALL WORT. HAS BEEN COMPLETED IN ACCORDANCE WITH THE TERMS OF TH`. O'I "FENCE F-P.'.RiT AND An ROVFD PLANS. 48 HOURS ADVANCE NOTICE 15 REQUESTED +.� FfIC+FOF (I F/jplp.Ir •.Y APPLE TREE FI 105 IIJT �iO1JT OF TANKS, INCLUDING RISEE CR COMPO(JEN75. COVERS TO GR^ -.i _L'ALL ALSO EE r<AD WATERTIGHT. MAPLE- TREE 5J CONTFAC70R SHALL VERIFY BUILDING 5t7BACK5, BUILDING HEIGHT, AND O CEDAR TREE BUILDING COVERAGE: COMPLIANCE WITH ZONING SETBACKS 15 NOT EXPRESSED J OR IMPI-IED HEREON. 6.)OWNER /CONTRACTOR. SHALL REVIEW AND APPROVE HOUSE LOCATION AND F SYSTEM DESIGN. CALCULATIONS: - GRADING PRIOR TO EXCAVATION. - - 7.) EXISTING CESSPOOL TO BE PUMPED DRY, FILLED WITH CLEAN SAND, SEWAGE DESIGN FLOW: - I BEDROOM DWELLING @ 110 GPD = I 10 GPD AND ABANDONED IN PLACE. TIGHT TANK. CAPACITY REQUIRED: DAILY FLOW = I 10 GPD @ 5CYT,' = 550 GAL. REQUIRED TIGHT TANK CAPACITY PROVIDED: ' 2000 GALLON MONO TIGHT TANK (MIN. ALLOWED) - INSTALL F" OVER ONE (1) - 2000 GALLON MONO TIGHT TANK ONE (1) - ALARM PANEL WITH FLOAT v - ONE (1) - POLYLOK 3008 -WEST - 24" PLASTIC FLAT COVER WITH FOAM GASKET Name Date COVER SHALL BE SCREWED TO RISER WITH PROVIDED 5QUARF_ DRIVE 5CRJEN5 24' PLASTIC COVER �y�jHC!/?� gP<'\AN OFA^ r SsL Fa Use POLYLOK 3008-WE5T > (Water -Tight and Screwed in Place) /1Gr /y;?yr/ y-� u<.< * ° ",tip a ev'>`J JOIiN g { Prono5ed EL= 19.5± hl. i O'RE1LLY41, ala NO. 4M3 'd cp 9' Proposed 1A 7+ 3 : x 1 :'FLOAT INSTALLATION NOTES:. 15 15.2 / Vehcl, ;racks (.)FLOAT SHALL BE INSTALLED WITH ACABLE WEIGHT M _ `'�xs'1FL'I sting - 2.) FLOAT SHALL BE INSTALLED 50 THAT THEY CAN BE x A ACCESSED FROM OUTLET MANHOLE COVER \G 3.) FLOAT MUST BE INSTALLED 50 THAT IT IS .I 1 OUTLET SHALL BE SEALED 15 15��-!, - .5 .- /-PRCPl7iED ROPT (SEE MOTES) _ %� r7' / FREE TO MOVE THROUGHOUT ITS TRAVEL 19.0± _ � 17.63 ON at 3/5 Capacity GROU (1373 Gal.) 4'-3' EL- G.0- YRB (TND 4 1'- 2'_6' HF;H -NDWATFR BASED ON MOTTLING .Tim Sherry N o m e s - 1q 13.6 - 14.4 BUOYANCY CALCULATIONS: 3 ° P.O. Box 1 69, East Dennis, Ma 02G41 13.5 F. r ... + a (.Ils I'` .,:+ ,m .,, JR I g0, P P f 2000 GALLON MONO SEPTIC TANK a E 1a9� 1304 / PROPOSED SITE SEPTIC SKETCf1 PLAN ,q t J S 236 Center Street, Yarmouthport, Ma N d 14,3 Fel=(1 .234118'X3.C)62:?LE/CF S• G-1 a JIM. �1REILLY $C ASSOCIATES INC. - 16,294 lbs 2000 GALLON MONO -, - S l_TANK 17,853 MIGHT TIGHT TANK S^�v 1j CB (TND) Fw = 17,853 IIs. (Per. Spec) c orc. ) Professional Engineering & Land Surveying Services BENCHMARK: F\.+1= 17,853 lbs > FBI= 16,293 lbs i "'- - _- - --` g g m o � Top of Concrete Bound U5E 5T -20C MONO 5EMC TANK BY 5HOREYP,ECA5T CONCRETE PRODUCTS N - EI =22.8± (1988 NAVDj (Based On High 7 �� �. ,,{t/� pn p� eQi4.3 �T WOR[ MUST CONFO O ALL UP#43/40 Groundwater EL=16.0) �J% /�/" 0 3O GO 90 1573 Main Street - Route BA P.O. Hos 1773 2p p p - (508)896-6801 `Office Brewster, MA 02631 (508)896-6602 Fax T - j 1\I U L#WS CX REGULArTIONS SCALE I"=3O'.. DATE: SCALE: BY: CHECK: JOB NUMBER: G:Wl1ot\Tlm5herryHomes\23GCenter5treet\7030TIGHT TANK.DWG 2/ 1 O/ 1 5 A5 Noted AFM KEF SMO -7030 saw �� r�i ri, rernTrR flCr]T f1 ATC -