Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2015LOT COVERAGE: DWELLING: 2560.48 SQ. FT. LOT SIZE: 16,002 SQ. FT. COVERAGE: 2,560.48/16,002 = 16% MAP 65 WNm Health Department PCL. 17 N PROVED Date MAP 65 ------- ---� PCL. 187o✓ /l.c�r. .2 1 — — — '9.34°05 E 14100 � - N L_ O T 5 — —1-£,-8o-2± –S:F. �"- F041/ ` x / 03' STOCKADE FENCE / 02 ' / z 26.7 , 1 ffyO � N i MAP 65 PCL. 21 i TP -2 TP -1 i PROP. 2 F3R 1 �wELLING GARAGE 1 TOF �102.5� 1 \ - C7 O 00 0 � RESER�� TELE RISER UTILITY POLE #873/2 0 -qD- CATCH BASIN LEGEND –{] --f- PROPOSED CONTOUR I ® PROPOSED SPOT GRADE EXISTING CONTOUR �i + 96.52 EXISTING SPOT GRADE W— PROPOSED WATER SERVICE t9 TEST PIT MAP 65 PCL. 16 SINGULAIR SESI 600 GPD DENITRIFICATION WASTEWATER TREATMENT SYSTEM MODEL 960 CONCRETE, DN 04 07 O J 30. T15 MAP 65 o PCL. 23 o 1 0 1-3' `n 10'� J J03 \. TBM HYDRANT TAG \ BOLT ELEV.= 102.9' \ UTILITY POLE #873 W 134.94 PA ' EIJGE OF 00 P k,TH 1101 * (HIGHPOINT OF ROAD LAYOUT) 5 FT STRIPOUT MAY BE REQUIRED (SEE NOTE 13) SCALE: 1" = 20' WEST YARMOUTH MICHELLE'S PATH v DANA'S PATH o c i JILLS PATH o LOCUS 56 JILL'S PATH LOCUS MAP LOCUS INFORMATION PLAN REF: BK 240 PG 021 WIND EXPOSURE: B TITLE REF: BK 19626 PG 226 PARCEL ID: MAP: 065 LOT: 022 ZONING SETBACKS: F:30', S:20', R:20' FLOOD ZONE: "X" OTHER AREAS COMMUNITY PANEL: 25001C -0586-J DATED:07/16/14 SITE AND SEPTIC PLAN LOCATED AT: 56 JILL'S PATH WEST YARMOUTH, MA PREPARED FOR MATT HOMER REVISED: NOVEMBER 24, 2015 a�M ofassq OF Mgss JOHN Z. o� D R M , DEMAREST, JR. No. 36859. m MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SHEET 1 OF 2 J#1475 NOTE: MAGNETIC'TAPE TO BE PLACED OVER ALL COVERS F.G. EL: 101.0 F.G. EL: 101.0 EAIE'rIC -4" MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 4• EFFLUENT ]t 2" OF 3/8" DOUBLE WASHED LINE H P STONE OR FILTER FABRIC 1' L: 99.55 RE -CIRCULATION BASIN (SEE DETAIL) F7NA1. CIARIRCATION ,,... CHA A LER SINGULAR SES1600 GPD DENITRIFICATION WASTEWATER TREATMENT SYSTEM MODEL 960 CONCRETE, DN NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) SEPTIC TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. EXCEPT AS NOTED BELOW: - VARIANCE FROM YARMOUTH BOARD OF HEALTH REG. 0.5 FT VARIANCE, FOUNDATION HEIGHT 1.5 FT ABOVE HIGH POINT OF ROAD, VS REQUIRED 2.0 FT. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBIUTY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. ALL PIPING TO BE 4" SCH 40 ® 1/8"/FT (UNLESS SPECIFIED) 11. IT IS THE RESPONSIBILITY OF THE OWNER/INSTALLER TO ENSURE FULL COMPLIANCE WITH THE REQUIREMENTS SET FORTH REGARDING THE USE OF A DE -NITRIFICATION SYSTEM (i.e., 0&M agreement, deed restrictions, testing standards and frequency, etc.) 12. A TWO (2) BEDROOM DEED RESTRICTION IS REQUIRED. 13. A 5 FT SOIL REMOVAL AROUND ENTIRE LEACHING TO TOP OF MEDIUM SAND LAYER MAY BE REQUIRED, REPLACE W/CLEAN MED. SAND 0 B 4" SCH 40 PVC s" Q S= 1% (MIN.) INV.99.05 2 OF. DEPTH INV.98.85 PROPOSED DB -3 DISTRIBUTION BOX TOP CONC. ELEV.= 99.30 INV. ELEV.= 98.30 - INV. ELEV.= 98.30 11 1010® wammaa® ®®10®®®® ®®®®- O ®®1010 1010®®®®®®®®® ®®®®®®®®®®® ®®®®®®®®®®® 4'/ 1 2 X 8.5' 3/4" - 1 -1/2 - DOUBLE WASHED STONE 4' / EFFECTIVE LENGTH = 25.0' 1 BREAKOUT ELEV.= 99.30 BOTTOM EL.= 96.30 3.75' 5 FT. 3.75' SEPARATION 5.00 FT. FEFFECTIVE WIDTH = 12.5' BOTTOM OF TESTHOLE EL: 91.30 _ SOIL ABSORPTION SYSTEM (SECTION) (500 GALLON LEACH CHAMBER) DESIGN CRITERIA SOIL LOGS PROVIDE RISERS COVERS OVER ALL ELEV. TOP COMPONENTS AND SET TO FINISH GRADE FOUNDATION Elev. TP -1 (Proposed) TP -2 FOR SPECIFIC DETAILS -SEE SHEET 3 = 102.50 F.G.EL: 101.50 F.G.EL: 101.50 REMOVABLE INSPECTION COVER •A GUWR WITH CAST-INHANDLE HANDLE /.r2n PROP. OUTLET: a• , SOIL EVALUATOR: DARREN M. MEYER, RS. CSE 1614 EL: 100.0 * ' PROV. RUBBE :° V-0- BOOT a' S' -D- 12" 100.93 a EL: 99.80 8" A' B .4 B LOAMY SAND 6" CRUSHED 9'-3„ 10YR 6/6 STONE(TYP.) Pte- 10YR 5/5 C> AERATION CHAMBER NOTE: MAGNETIC'TAPE TO BE PLACED OVER ALL COVERS F.G. EL: 101.0 F.G. EL: 101.0 EAIE'rIC -4" MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 4• EFFLUENT ]t 2" OF 3/8" DOUBLE WASHED LINE H P STONE OR FILTER FABRIC 1' L: 99.55 RE -CIRCULATION BASIN (SEE DETAIL) F7NA1. CIARIRCATION ,,... CHA A LER SINGULAR SES1600 GPD DENITRIFICATION WASTEWATER TREATMENT SYSTEM MODEL 960 CONCRETE, DN NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) SEPTIC TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. EXCEPT AS NOTED BELOW: - VARIANCE FROM YARMOUTH BOARD OF HEALTH REG. 0.5 FT VARIANCE, FOUNDATION HEIGHT 1.5 FT ABOVE HIGH POINT OF ROAD, VS REQUIRED 2.0 FT. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBIUTY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. ALL PIPING TO BE 4" SCH 40 ® 1/8"/FT (UNLESS SPECIFIED) 11. IT IS THE RESPONSIBILITY OF THE OWNER/INSTALLER TO ENSURE FULL COMPLIANCE WITH THE REQUIREMENTS SET FORTH REGARDING THE USE OF A DE -NITRIFICATION SYSTEM (i.e., 0&M agreement, deed restrictions, testing standards and frequency, etc.) 12. A TWO (2) BEDROOM DEED RESTRICTION IS REQUIRED. 13. A 5 FT SOIL REMOVAL AROUND ENTIRE LEACHING TO TOP OF MEDIUM SAND LAYER MAY BE REQUIRED, REPLACE W/CLEAN MED. SAND 0 B 4" SCH 40 PVC s" Q S= 1% (MIN.) INV.99.05 2 OF. DEPTH INV.98.85 PROPOSED DB -3 DISTRIBUTION BOX TOP CONC. ELEV.= 99.30 INV. ELEV.= 98.30 - INV. ELEV.= 98.30 11 1010® wammaa® ®®10®®®® ®®®®- O ®®1010 1010®®®®®®®®® ®®®®®®®®®®® ®®®®®®®®®®® 4'/ 1 2 X 8.5' 3/4" - 1 -1/2 - DOUBLE WASHED STONE 4' / EFFECTIVE LENGTH = 25.0' 1 BREAKOUT ELEV.= 99.30 BOTTOM EL.= 96.30 3.75' 5 FT. 3.75' SEPARATION 5.00 FT. FEFFECTIVE WIDTH = 12.5' BOTTOM OF TESTHOLE EL: 91.30 _ SOIL ABSORPTION SYSTEM (SECTION) (500 GALLON LEACH CHAMBER) DESIGN CRITERIA SOIL LOGS Elev. TP -1 Depth Elev. TP -2 Depth DATE: APRIL 15, 2015 102.30 A 0" 101.60 p` - 0" SOIL EVALUATOR: DARREN M. MEYER, RS. CSE 1614 LOAMY / 10YR 4/1 1 LOAMY SAND tOYR 5/3 WITNESS: AMY VONHONE, YARMOUTH HEALTH 101.30 12" 100.93 8" B LOAMY SAND B LOAMY SAND 10YR 6/6 10YR 5/5 98.30 C 48" 98.93 C1 32" SANDY LOAM MEDIUM SAND 97.27/95.60 IOYR 5/6 52"/72" 2.5Y 7 4 C2 MEDIUM SAND 2.5Y 6/4 91.30 132" 91.60 120" PERC RATE <2 MIN/IN. ("C" HORIZON) NO GROUNDWATER OBSERVED. • I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil EveL Exam in October, 1999. DESIGN CRITERIA N OF M�Ss9�y D/�RREN MI �, NUMBER OF BEDROOMS: PROP. 2 BEDROOM DWELLING SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN GARBAGE GRINDER: NO DAILY FLOW: 110 G.P.D./BR DESIGN FLOW: 2 X 11OGPD = 220 G.P.D. (MIN REQ'D) ALLOWABLE FLOW: SINGULAR (660GPD/40,000 SF) = 6667 SF/110 GPD 110GPD/6667SF X 16,002SF(ON LOT) = 264 GPD ALLOWED ON LOT PROPOSED SEPTIC TANK: 220 GPD X 2.0 = 440 GPD USE SINGULAIR SESI600 GPD DENITRIFICATION WASTEWATER TREATMENT SYSTEM MODEL 960 CONCRETE, DN ***USE UNDER MADEP PROVISIONAL USE APPROVAL *** LEACHING AREA REQUIRED: (220) /0.74 = 297.29 S.F. USE 2-50OG PRECAST LEACHING CHAMBER WITH 4' STONE ON ENDS AND 3.75' STONE ON SIDES i25'Lx12.5'Wx2V BOTTOM AREA: 25 x 12.5 = 312.50 SF SIDE AREA: (25 + 12.5) X 2 X 2 = 150 SF TOTAL SQUARE FEET PROVIDED = 462.50 vs. 297.29 REQ'D DESIGN FLOW PROVIDED: 0.74(462.5 S.F.) = 342.3 G.P.D. vs. 220 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 56 JILL'S PATH, WEST YARMOUTH, MA Prepared for: Homer System Design and Site Plan by: SCALE DRAWN DATE: MEYER& SONS, INC. N.T.S. DMM 11/09/15 PO BOX 981 REV. DATE: CHECKED SHEET NO. EAST SANDWICH, Ma o2537 508.-3622922 11/24/15 DMM 2 of 3 ALTERNATE I N LET LOCATION 4" DIAMETER INLET LINE REMOVABLE INSPECTION COVER WITH CAST -IN-PLACE HANDLE UNDERGROUND POWER SUPPLY TO AERATOR AND RE -CIRCULATION PUMP II 1 II I I � AERATOR -1 L 1 PLAN VIEW REMOVABLE _\ INSPECTION COVER SINGULAIR WITH CAST -IN-PLACE AERATOR HANDLE �- 0 18' 0 4" INLET AND OUTLET INTEGRATED PIPE GASKET CONNECTIONS -T _ WITH STAINLESS t � - STEEL RETRACTABLE , » CLAMPS -0 CONTRACTOR TO INSTALL 4" SDR 35 PVC TEE 9,_3„ - PRE-TREATMENT EXTENDED CHAMBER AERATION SECTION A -A CHAMBER BIO -KINETIC SYSTEM 1" PVC RE -CIRCULATION PIPE TO PRETREATMENT CHAMBER UL LISTED WEATHERPROOF 11 OV ELECTRICAL ENCLOSURE POLY-LOK BASIN 24"X36" BASIN OR APPROVED EQUAL A 4" DIAMETER EFFLUENT LINE 1" PVC RE -CIRCULATION PIPE BIO -KINETIC SYSTEM 1'-4" 4" DIAMETER I LET AND TEE ABS ROPUSTA 100 W/ TSR -CIRCULATION PUMP OR APPROVED EQUAL CONCRETE ANTI FLOATATION I COLLAR ,AS NEEDED BY DESIGN POLY-LOK BASIN 24"X36" BASIN OR APPROVED EQUAL GENERAL NOTES 1. THE SINGULAIR MODEL 960 IS SOLD AND SERVICED EXCLUSIVELY 4" DIAMETER BY SIEGMUND ENVIRONMENTAL OUTLET SERVICES INC., 49 PAVILION AVE, PROVIDENCE RI 02905 -..- 2. SEE ATTACHED FOR ANTI -FLOTATION CALCULATIONS 4, RI DEM & MA DEP MAY REQUIRE SESI TO REVIEW THE PLANS PRIOR TO SUBMISSION. SES WILL REVIEW PLANS ONLY FOR ; CONFORMITY WITH GENERAL LAYOUT AND DIMENSIONS AND NOT FOR APPLICABILITY OF USE RE -CIRCULATION BASIN DETAIL BIO-KINETIC®SYSTEM MOUNTING RISER AND COVER 4" DIAMETER EFFLUENT'. LINE RE -CIRCULATION BASIN (SEE DETAIL) `-FINAL CLARIFICATION BIO -STATIC CHAMBER SLUDGE RETURN 5. THE SINGULAIR MODEL 960 MAY BE LOCATED UNDER A PARKING LOT OR DRIVEWAY IF MODIFICATIONS ARE MADE TO THE DESIGN. SEE SES DRAWING FOR H-20 LOADING DESIGN 6. ALL SINGULAIR MODEL 960 RISER COVERS MUST BE ACCESSIBLE AT DEPTH OF GRADE FOR SERVICE & FILL 1'-2' INSPECTION 7. CONCRETE TANK MEETS ASTM STANDARD SPECIFICATION FOR PRECAST CONCRETE SEPTIC TANKS C-1227-09, 51- 6" ---� OUTLET END VIEW 1Ar-1 �-"--