Loading...
HomeMy WebLinkAboutEngineered Plan - 2016N KEY: TH-1 100.0 LOCUS EXISTING CONTOUR: - - - - 4 _ ELEV. PROPOSED CONTOUR: ........... • 10" EXISTING SPOT ELEVATION: 25.5 W PORCH PROPOSED SPOT ELEVATION: 25.5 0/A HORIZON FORTUNE RD 0 TEST HOLE: WITNESS: AMY VON HONE, R.S. LOAMY SAND 10YR 3/1 UTILITY POLE: -p- 0_5 S FENCE LINE: :0 HYDRANT: B HORIZON 0 RETAINING WALL: LOCATION MAP LOT 58 (12,737 SF) ASSESSORS MAP: 123 PARCEL: 71 PLAN BOOK: 241, PAGE: 109 M I --,y '-qAi, 99 R SEPTIC SYSTEM DESIGN FLOW ESTIMATE: (3 BEDROOM DESIGN,MINIMUM) 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) =_L12 GAL/DAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAL/DAY CAPACITY = 349 GAL/DAY 100 ` Fdgepav i R=212` e��I/betrn i \ p A--81.3'0,os� ., 98 I `99 112" \ o \ s�, I tree 100 °o co I I 101 97 I I ( OR VFO I 12" tree / 98 I l 1`40 / 96 t 97 95 / G pO�ch I W 94 93 No fan 0 �nV� 93 94 95 T 96 oak T / m F 11 994 �E O 95�� y ! / Az bb th-1he h' b q'�ti Ova 96 iC lllllllljjjjjjjJ BENCHMARK AT - RIGHT CORNER OF BULKHEAD ELEVATION = 101.46 97 \ 12" oaks 94 Q -99_ oak_ - 98- - 2'0"jO- 9s 97 / ap(c i /s °nc, b7 96 / / / V °Cki7;e j 95 J 94 1 SEPTIC SYSTEM SECTION 102.17 TOP OF ° FOUNDATION 99.4 ELEV, a ° 98.15 / ELEV. 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN COVERS WITHIN 6" OF FINISHED GRAC 1'42'/78 MAX. C 1$f COVER �L(1' MIN) ELEV. 96.48 96.31 ELEV. D -BOX ELEV. (6" OF STONE UNDER OR MECHANICALLY COMPACTED) -GAS BAFFLE AT OUTLET TEE ELEV. PEASTONE OR FILTER FABRIC 3/4" - 1 1/2" WASHED STONE //-INSPECTION PORT ELEV.= 97.0 l l9° °I'I 94.17 4 <--> ELEV. -25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) Date RECEIVED AUG1 0 x6116 ,�. HEALTH DEPT ( SITE PLAN i ER 'v 4 " LOCATION: 51 AMY LN., YARMOUTHPORT, MA r I `� : •'i1� �w PREPARED FOR: JACK HASTINGS DATE: 1-22-16 SCALE: V = 20' BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048 TH-1 100.0 GARAGE TEST HOLE LOGS _ ELEV. 10" FILL 99.2 PORCH ENGINEER: THOMAS McLELLAN, P.E. 0/A HORIZON BED WITNESS: AMY VON HONE, R.S. LOAMY SAND 10YR 3/1 LIVING ROOM ROOM 16" DATE: 1-21-16 98.7 B HORIZON PERCOLATION RATE: < 2 MIN/IN LOAMY SAND 34" 10YR 5/8 97.2 BATH KITCHEN BED C HORIZON MEDIUM SAND ROOM PERC AT 60" 2.5Y 7/6 W/p DINING BATH 132" 89.0 PORCH DECK Eh NO GROUND WATER ENCOUNTERED NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. EXISTING FLOOR PLAN 3. SCHEDULE 40 - 4' PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING LEACH PIT IS TO BE PUMPED AND FILLED WITH SAND OR REMOVED. Yarmorth Health Dep rtint 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. _,_APPROVED Date RECEIVED AUG1 0 x6116 ,�. HEALTH DEPT ( SITE PLAN i ER 'v 4 " LOCATION: 51 AMY LN., YARMOUTHPORT, MA r I `� : •'i1� �w PREPARED FOR: JACK HASTINGS DATE: 1-22-16 SCALE: V = 20' BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048