Loading...
HomeMy WebLinkAboutEngineered Plan - 2000TOP FNDN. AT EL. 22.6' SYSTEM PROFILE T EST HOLE LOGS ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO g o RI CK, RS 21.0' MINIMUM .75' OF COVER OVER PRECAST / WITHIN 6" of FIN. GRADE ENGINEER: 2% SLOPE REQUIRED OVER SYSTEM WITNESS: AMY VON HONE, RS 20.0' RUN PIPE LEVEL 2" DOUBLE WASHED PEASTONE -FOR DATE: NOVEMBER 16, 2000 !19:75' - 18.0' FIRST 2' PROPOSED�0 17.0' GALLON SEPTIC 17, 75' Ll - < 2 MIN/INCH PERC. RATE - :•, : - GAS Q TANK (H- 10) 16.5 16.55 d GLASS SOILS P# MIN BAFFLE 16.72' `"'� 2' ® SIDES ( 2 9: SLOPE) \_6" CRUSHED STONE OR MECHANICAL 2' T/ ELEV. COMPACTION. (15.221 f 21 20-n' DEPTH OF FLOW 4, ( 7 r SLOPE) �-.o� 1 4" o<�� 14.5' TEE SIZES: INLET DEPTH 10" 3/4" TO 1 1/2" DOUBLE WASHED STONE 2" OUTLET DEPTH 14" FOUNDATION- 19' SEPTIC TANK 15' D' BOX 3' LEACHING 8pp FACILITY 5.5' Al 0 A/E LFS 1OYR 4/1 Bw LS 10YR 5/6 I C i MS 2.5Y 6/4 + 20.0 �y c� _ NO WATER ENCOUNTERED NOTES: - OT 222 r �. SEPTIC DESIGN: GARBAGE DISPOSER I NOT ALLOWED APPROXIMATED FROM QUAD MAP 1380 SQ. FT. ►.� ( E s ) 1. DATUM IS 0.32 CRES 19.3 DESIGN FLOW: 3 BEDROOMS_- (110 r„pnl 30 ,._ G -P4 _ - - - - _ _ __- - Ml7NlCIPAL WATER IS EXISTING tis' -G y � USE A 330 GPD DESIGN FLOW 21.4 vo 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. TH 0.3 SEPTIC TANK: 330 GPD (2 ) = 660 34.5 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-- 10 a �' USE A GALLON SEPTIC TANK _ 0 5: PIPE JOINTS TO BE MADE WATERTIGHT. � ! � 500- INV. OUT = '"� 6. CONSTRUCTION DETAILS TO BE . IN ACCORDANCE WITH MASS. 19.78' 0' v � LEACHING: ENVIRONMENTAL CODE TITLE V. m' SIDES: 2(30 + 9.83)2 (•74) _ 118 7.` THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE o EXIST. 22.63070 BOTTOM: x 9.83 (.74) = .218 USED FOR LOT LINE STAKING. 04 DWELL 8. ` PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 454S.F. 336 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT + 19. o o G USE (4) H-20 HIGH CAPACITY INFILTRATORS WITH INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED n TOP. FNDN. = W b FROM BOARD OF HEALTH. 0 22.6 21.4 1 3.5' STONE AT SIDES, 2.5' AT ENDS AND 14" UNDER 10. PUMP &REMOVEAN CLEAN FILL OR W ( / SAND) EXISTING SEPTIC SYSTEM Op 0. 19.9 0. + 21.3 PAVED DRIVE 4 20.0 21.9 LEGEND TI TLE S SI TE PLAN + 8 /H UTjL. ' 100.0 PROPOSED T 5 � SPO ELEVATION OF + 8 `�--- 2116 1 25 CAPT. NOYES ROAD 00x0 EXISTING SPOT ELEVATION + 20.8 + .9 � 100 IN .THE TOWN OF: 120.00` 20.3 PROPOSED CONTOUR (SOUTH) YARMOUTH a � + 20. + 21.3 0 100 EXISTING CONTOUR PREPARED FOR: 4L + 20.8 20 0 20 40 60 + 20.6 BOARD OF HEALTH PROVED DATENAIL SET IN UTILITY POLE � O MA SCALE: 1" _ 20' DATE: NOVEMBER 20, 2000 . ELEVATION 21.59 (ASSMD QUAD) off 508-362-4541 fox G3(CCrVLFEDD (OR USE TOP FNDN AT EL. 22.6) 1 • �1N Of MqJ ����N OF JAN Z 6 down CO pe engineering, Inc. o� ARNE NE K G Z� H.HEALTH DEPT. U "t A rte•• CIVIL ENGINEERS OJALA CIVIL F, LAND SURVEYORS 9 N o. s3a$ 7s2 00-329 - 939 rain st, yarmouth, ria 0675 A H. OJALA, P. L, S. DAT_