HomeMy WebLinkAbout132.123 - Title 5 Site Plan (Copy 2)SYSTEM PROFILE TOP FNDN. AT EL. 26.0'NOT TO SCALE) ACCESS COVER TO WITHIN 6" OF FIN. GRADE ( ACCESS COVER (WATERTIGHT) TO % MINIMUM .75' OF COVER OVER PRECAST / WITHIN 6" OF FIN. GRADE RUN PIPE LEVEL FOR FIRST 2' PROPOSED GALLON SEPTIC 22.25' 2% SLOPE REQUIRED OVER SYSTEM 2" DOUBLE WASHED PEASTONE 3' MAX. 22.0' ._22.50 TANK (H- 10 ) GAS 21.45' �� 21.28 MM M CIC' BAFFLE MMMM M Moon MIN P21,17 MMMM M MMMM ( % SLOPE) �6" CRUSHED STONE OR MECHANICAL 2' M [] (� M M E] M ' COMPACTION. (15.221 (21) DEPTH OF FLOW = 4' (2.5 % SLOPE) (--1-7 SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STONE TEE SIZES: INLET DEPTH = 10" OUTLET DEPTH - 14" FOUNDATION- 21' SEPTIC TANK 31 D' BOX - BENCHMARK CONCRETE BOUND ELEV = 25.0' �-24.40 J 2�. PROP, 4'x 6'x 2' UTILITY ~� SCREEN BOARD FENCE 5.01 +25.31, HIGH PT. 9j LOT 2 15,875 SFt / N 24.91 'S 0' 2^ f o } < / + .36 `24.5 i Vy 25.2 1 PROP. 4 BR ' U � DWELLING ' DECK 125.14 TOP FNDN. 26.0' TH 2 -24.9 PROP. LI T$ 4.56 DRAINAGE �. `�� GAR MANHOLE PROP. BRICK +23.54 COVER �,� '� WALK , ` 0 13' +23.61 36 �, /r �Cq3 i ®e .57 TH1 -f-24.78 R<SER i 2 , �• +23.97 LOT 1 +24.221 -2 TOWN OF YARMOUTH VARIANCE REO'D: TOP OF +0,00 1,.1 FOUNDATION TO BE 1.09' ABOVE HIGH POINT IN v N ROAD (0.91' VARIANCE) +23.44 +21.17 00-095 19.17' TEST HOLE LOGS ENGINEER: MICHAEL FARIA, SE WITNESS: KELDA GORMAN, SE DATE: 5/10/00 PERC. RATE _ < 2 MIN/INCH CLASS i SOILS P# O" 4 DISTURBED Ap ELEV. Q 23_2' DISTURBED Ap 24.0' LEACHINGASSESSORS MAP 132 PARCEL 123 FACILITY 7.97' 48" 19.2' 48" 20.0' ZONING DISTRICT: R 40 (CURRENT) YARD SETBACKS: FRONT = 30' C C SIDE = 20' (REAR = 20' 11.2' MS MS PLAN REF. - 435/39 FLOOD ZONE: C 2.5Y 7/4 2.5Y 7/4 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY DOWN TO SUITABLE SOIL LAYER. WITH CLEAN MED. SAND. 144" 11.2' 144" 12.0' NO WATER ENCOUNTERED NOTES: SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED ) 1. DATUM IS APPROXIMATED FROM QUAD DESIGN FLOW: 4- BEDROOMS (110 GPD) = 440 GPD 2. MUNICIPAL WATER IS `gV'AI ARI F USE A Ala GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8" PER FMT. N SEPTIC TANK: 440 GPD (Z) = 880 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- .0 N 5. PIPE JOINTS TO BE MADE WATERTIGHT. +21.40 USE A _1_500 GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. LEACHING: ENVIRONMENTAL CODE TITLE V. 2(33.5 + 12.83) 2 (.74) = 137 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT 4.31 SIDES: TO BE USED FOR ANY OTHER PURPOSE. BOTTOM: 33.5 x 12.83 (.74} = 318 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 615 S. F. 455 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT USE (3 ) 500 GAL. LEACHING CHAMBERS (ACME OR INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. +23.21 WI 4' STONE ALL AROUND 10. WATER TEST D'BOX FOR LEVELNESS LEGENDT ITLE 5 SITE PLAN 1 100.0 PROPOSED SPOT ELEVATION OF 42 CENTER STREET 100x0 EXISTING SPOT ELEVATION IN THE TOWN OF: LOT 3 100 PROPOSED CONTOUR YARMOUTH (PORT) - 100- EXISTING CONTOUR PREPARED FOR: YARN PHILBROOK _""�EDGE OF POOL BOARD OF HEALTH MA SCALE: 1 = 20 DATE: I,I OCTOBER 5, 2002 APPROVED DATE REV. 12/10/02 (TF EL.) REV. 1/17/03 (TF) off 508-362-4541 lox 508 362-9880 ✓'`= -' �Ik Of if /PIH down Cape engineering, inc. ARN �r���� ARTIER �o E yc�� o$' OJRLA !! � t u u OJALA =� " CIVIL '!, ,;, Li 0 4 2003 CIVIL ENGINEERS No. 34017, No.3 LAND SURVEYORS Al 939 mein st, yarmouth, ma 02675 XRN H. OJALA, P.L.S. -DATE