Loading...
HomeMy WebLinkAbout132.123 - Title 5 Site Plan (Copy 5)TOP FNDN. AT EL. 26.0' SYSTEM PROFILE .� ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) j-'-' ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST f WITHIN _6" OF FIN. GRADE 27 SLOPE PEQUIRED OVER SYSTEM -171 RUN PIPE LEVEL FOR FIRST 2' PROPGSED � 5001/ 22.50, GALLON SEPTIC 22,25' H-20 TANK (H:- 20) GAS 41.28' BAFFLE 21.45 � MIN ( 2 % SLOPE) �6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) ;ln DEPTH OF FLOW 4' (2.5 %SLOPE 1 TE SIZES: ) (-% SLOPE) INLET DEPTH 10" OUTLET DEPTH = 14" FOUNDATION- 23' SEPTIC TANK 31' N )[-24.4c / r HIGH PT.. 1 o / LOT 2 W/ 15,875 SFt #24.91 // ry. / + .38 W 25.2 v 25.14 BENCHMARK CONCRETE BOUND ELEV - 250' PROP. 4 BR DWELLING TOP FNDN. - 2 PROP. U TS / 4.56 ` PgPCh' DRAINAGE MANHOLE COVER a - 61 AL PROP. B +24.78 �29R..•�``� LOT 1 TOWN OF YARMOUTH VARIANCE REO'D: TOP OF FOUNDATION TO BE 1.09' ABOVE HIGH POINT IN ROAD (0.91' VARIANCE) 00-095 DECK 2" DOUBLE WASHED PEASTONE R:I PROP, 4'x 6'x 2' UTILITY SCREEN BOARD FENCE +25.31 3/4" TO 1 1/2" DOUBLE WASHED SION.= 13' LEACH) JG FACILITY TEST HOLE LDS ENGINEER: MICS AEL FARIA, SE 25.0' WITNESS: KWA GORMAN, SE DATE: 5/10/00 3' MAX, PERC. RATE _ < 2 MIN/INCH 22.0' CLASS I SOILS P# tAROUIND19.17' Q ELEV. Cz� 0" 23,2, 0° DISTURBED DISTURBED AID AD 7.97' 48" 19.2' 48" C C 11.2' MS MS 2.5Y 7/4 2.5Y 7/4 5' REMOVAL OF UNSUITl.BLE SOIL REQUIRED AROUND PERIMETER 'OF _EACHING FACILITY, DOWN TO SUITABLE SOI). LAYER. REPLACE WITH CLEAN MED. SAND. GAR y• \ +2'4+3 ; fL 2 +23.21 36 ;�, TH1 2� ni+ +2422 -22' +21.17 94 LOT 3 24.0' Gli ASSESSORS MAP 132 PARCEL 123 ZONING DISTRICT: R 40 (CURRENT) YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - 435/39 FLOOD ZONE: C 144" 11.2' 144" 12.0' NO WATER ENCOUNTEREDNO TES: SEPTIC DESIGN: (GARBAGE DrSPOSER IS NOT ALLOWED ) 1. DATUM IS _APPROXIMATED FROM QUAD -)ESIGN FLOW: 4_ BEDROOMS (I10 _GPD) = 440 GPD 2. M'JNICIPAI, Wr.TER IS '-A� LI ARIf USE A 440 GPD DESIGN FLOW 3. MINIMUM PIPE PI:CH TO BE 1/8 NtK LOUT. SEPTIC TANK: 440 GPD (_2 80 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- -0 5. PIPE JOINTS TO BE MADE WATERTIGHT. +21.40 USE A _1500 GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS, LEACHING: ENVIRONMENTAL CODE TITLE V. SIDES: 2(33.5.+ 12.83) 2 (.74) = 137 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NCT .31 TO BE USED FOR ANY OTHER PURPOSE, BOTTOM; 33.5 x 12.83 (.74) = 318 8, PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 615 S.F. 455 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT JSE (3) H-20 500 GAL, LEACHING CHAMBERS (ACME OR INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH, QUAL) WITH 4' STONE ALL AROUND 10. WATER TEST D'BOX FOR LEVELNESS LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR -- 100 - EXISTING CONTOUR BOARD OF HEALTH ,APPROVED DATE MA ILD off 508-362-4541 fox 508 362-9880 down cape engineering, i %) 0 CIVIL ENGINEER LAND SURVEYORS a� 939 main st. yarmouth, ma 02675 TITLE 5 SITE PLAN OF 42 CENTER STREET _ IN THE TOWN OF: YARMOUTH (PORT) PREPARED FOR: YARN PHILBROOK 20 0 20 40 60 SCALE: 1" = 20' DATE: OCTOBER 5, 2002 REV. 12/10/02 (TF EL.) REV. 1/17/03 (TF) w..l REV. 3/31/03 (MOVE HSE) I LIN. L ✓J/ ARNE H. OJALA, P.E., P.L.S. DATE 0000 LJ 0000 0000 0 MF -1==0000 F21.17' 0 0000 2 0000 0 0 M 0 M I R:I PROP, 4'x 6'x 2' UTILITY SCREEN BOARD FENCE +25.31 3/4" TO 1 1/2" DOUBLE WASHED SION.= 13' LEACH) JG FACILITY TEST HOLE LDS ENGINEER: MICS AEL FARIA, SE 25.0' WITNESS: KWA GORMAN, SE DATE: 5/10/00 3' MAX, PERC. RATE _ < 2 MIN/INCH 22.0' CLASS I SOILS P# tAROUIND19.17' Q ELEV. Cz� 0" 23,2, 0° DISTURBED DISTURBED AID AD 7.97' 48" 19.2' 48" C C 11.2' MS MS 2.5Y 7/4 2.5Y 7/4 5' REMOVAL OF UNSUITl.BLE SOIL REQUIRED AROUND PERIMETER 'OF _EACHING FACILITY, DOWN TO SUITABLE SOI). LAYER. REPLACE WITH CLEAN MED. SAND. GAR y• \ +2'4+3 ; fL 2 +23.21 36 ;�, TH1 2� ni+ +2422 -22' +21.17 94 LOT 3 24.0' Gli ASSESSORS MAP 132 PARCEL 123 ZONING DISTRICT: R 40 (CURRENT) YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - 435/39 FLOOD ZONE: C 144" 11.2' 144" 12.0' NO WATER ENCOUNTEREDNO TES: SEPTIC DESIGN: (GARBAGE DrSPOSER IS NOT ALLOWED ) 1. DATUM IS _APPROXIMATED FROM QUAD -)ESIGN FLOW: 4_ BEDROOMS (I10 _GPD) = 440 GPD 2. M'JNICIPAI, Wr.TER IS '-A� LI ARIf USE A 440 GPD DESIGN FLOW 3. MINIMUM PIPE PI:CH TO BE 1/8 NtK LOUT. SEPTIC TANK: 440 GPD (_2 80 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- -0 5. PIPE JOINTS TO BE MADE WATERTIGHT. +21.40 USE A _1500 GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS, LEACHING: ENVIRONMENTAL CODE TITLE V. SIDES: 2(33.5.+ 12.83) 2 (.74) = 137 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NCT .31 TO BE USED FOR ANY OTHER PURPOSE, BOTTOM; 33.5 x 12.83 (.74) = 318 8, PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 615 S.F. 455 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT JSE (3) H-20 500 GAL, LEACHING CHAMBERS (ACME OR INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH, QUAL) WITH 4' STONE ALL AROUND 10. WATER TEST D'BOX FOR LEVELNESS LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR -- 100 - EXISTING CONTOUR BOARD OF HEALTH ,APPROVED DATE MA ILD off 508-362-4541 fox 508 362-9880 down cape engineering, i %) 0 CIVIL ENGINEER LAND SURVEYORS a� 939 main st. yarmouth, ma 02675 TITLE 5 SITE PLAN OF 42 CENTER STREET _ IN THE TOWN OF: YARMOUTH (PORT) PREPARED FOR: YARN PHILBROOK 20 0 20 40 60 SCALE: 1" = 20' DATE: OCTOBER 5, 2002 REV. 12/10/02 (TF EL.) REV. 1/17/03 (TF) w..l REV. 3/31/03 (MOVE HSE) I LIN. L ✓J/ ARNE H. OJALA, P.E., P.L.S. DATE