HomeMy WebLinkAbout29 Charles Street - Site & Sewage PlanT.D.F. AT EL. 32.0' SEPTIC PROFILE ACCE covr, TO WITHIN 6" OF FIN. .GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO 31 XO MINIMUM 75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 29.0' PROPOSED15 00 GALLON SEPTIC 28.80 TANK (H- 10 ) 2 L SLOPE) DEPTH OF FLOW = 4 TEE SIZES: INLET DEPTH = 1O" OUTLET DEPTH = 14" FOUNDATION- 10 i RUN PIPE LEVEL /FOR FIRST 2' 128 55A27.46AFFLE 27.63' �� 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) (? % SLOPE) 2% SLOPE REQUIRED OVER SYSTEM 2" DOUBLE WASHED PEASTONE w w w w Mwslal w w wwNiljjj 3/4" TO 1 1/2" DOUBLE WASHED STONE �- TEST HOLE LOGS ENGINEER: A.H. OJALA, PE :51.0' WITNESS: AMY VON HONE, RS DATE: JUNE 25, 1998 3' MAX. PERC. RATE _ < 2 MIN. PER INCH 28.0' CLASS 1 SOILS P# N/A 2' SEPTIC 'TANK 25' D' BOX 15' LEACHING FACILITY 4.9' 19,+y 20.3' GROUNDWATER ESTIMATED AT EL. 6.0' BENCHMARK HYDRANT TAG BOLT #1042 EL = 31.25 `►+!,,.230.36 ti ' LOT 1 %l N 40,787 s.f. / (0.94 ac.) , TH2 31 co 2 aPROP. 4 BR i ' / DWELLING 60' � 29 (0� �l HIGH PT. fu c° TOP FNDN = n / I... / TH1 32.0' W /11-4 ry CO 1 1� 230.36 LOT 2 98-241 ASSESSORS MAP 53 PARCEL M9 ZONING DISTRICT: R-40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF, - 426/34 FLOOD ZONE: C 130" Q ELEV. Q EL EV. O" 31.2, 0" 3118' }- NOTES' 0 & A 0 & A SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) 1. DATUM IS APPROXIMATED FROM DENNIS QUAD DESIGN FLOW:4- BEDROOMS ( 110 GPD) = 440 GPD 2. 6„ LS 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. g" LS DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. E LS 1OYR4/1 8" 6. CONSTRUCTION B 8 ENVIRONMENTAL LS SIDES: 2(33.5 + 12.83) 2 (.74) = 137 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE LS USED FOR LOT LINE STAKING. 32" 10YR 5/6 28.5 30" 10YR 5/8 29.3 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 615 S.F. 445 GPD 9. Cl INSPECTION BYIBOARD OF HEALTH AND PERMISSION OBTAINED USE (3) 500 GAL. ACME OR EQUAL LEACHING M /C FROM BOARD OF HEALTH, CHAMBERS WITH 4' OF STONE ALL AROUND C 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR 48" 10YR 5/6 TO COMMENCEMENT OF WORK. LEGEND MFS 100.0 PROPOSED SPOT ELEVATION OF#,3rl 2.5Y 6/4 CHARLES STREET C2 IN M /C 100 PROPOSED CONTOUR C� (SOUTH) YARMOUTH 2.5Y 7/3 ASSESSORS MAP 53 PARCEL M9 ZONING DISTRICT: R-40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF, - 426/34 FLOOD ZONE: C 130" 20_3 120" J 21:8' }- NOTES' NO WATER ENCOUNTERED SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) 1. DATUM IS APPROXIMATED FROM DENNIS QUAD DESIGN FLOW:4- BEDROOMS ( 110 GPD) = 440 GPD 2. MUNICIPAL WATER IS AVAILABLE l = n_4- _ _ DEG;GFLGVJ 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. SEPTIC TANK: 440 GPD ( 2 ) = 880 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. USE A 1500_ GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. LEACHING: ENVIRONMENTAL CODE TITLE V. SIDES: 2(33.5 + 12.83) 2 (.74) = 137 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 33.5 x 12.83 (.74) = 318 BOTTOM: 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 615 S.F. 445 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BYIBOARD OF HEALTH AND PERMISSION OBTAINED USE (3) 500 GAL. ACME OR EQUAL LEACHING FROM BOARD OF HEALTH, CHAMBERS WITH 4' OF STONE ALL AROUND 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. LEGEND Sl AND SEWAGE ftAN 100.0 PROPOSED SPOT ELEVATION OF#,3rl CHARLES STREET 100x0 EXISTING SPOT ELEVATION IN THE TOWN OF: 100 PROPOSED CONTOUR C� (SOUTH) YARMOUTH - - 100- - EXISTING CONTOUR PREPARED FOR: M/M BILL THIELMAN 30 0 30 8O -90 BOARD OF HEALTH R VED DATE off 508-362-4541 fax 508 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma 02675 SCALE: 1" = 30' DATE: JULY 30, 1998 /27/99 P. E., P.L.S 120 DATE his/ Z�i� --