Loading...
HomeMy WebLinkAbout48.39.2 - Title 5 Site Plan (Copy 2)TOP FNDN EL. 23.0' SYSTEM PROFILE ACCESS COVER TO FIN. GRADE (NOT TO SCALE) FL /- ACCESS COVER (WATERTIGHT) TO 21.0' MINIMUM 75' nr rnvrc nvao WITHIN 6" OF FIN. GRADE 19.0' PROPOSED 1500 RUN PIPE LEVEL FOR FIRST 2' GALLON SEPTIC r�\ 71'TANK (H- 20) GASBAFFLE 18.02' ��7.85 ( % SLOPE) �__6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) DEPTH OF FLOW 4 TEE SIZES: (-2-7 SLOPE) ( % SLOPE) INLET DEPTH 10 OUTLET DEPTH = 14" FOUNDATION- 10' SEPTIC TANK 22' BENCHMARK HYDRANT TAG BOLT ELEV = 22.31' 1T ROAD 88 - TP.CU1 K - '' 3 0 2% SLOPE REQUIRED OVER SYSTEM 2" DOUBLE WASHED PEASTONE \ H-20 3/4" TO 1 1/2" DOUBLE WASHE-) STONE 3' OF pP�O/ I 18.20 E N pY 5SIGN i J8.19 2.5Y 6/4 .o- y C Ti O RT '<B. w. -,� Roy oN ��c 20.5' 18" MIN 3' MAX. 18.26' 0 17.26' -L 5' LEA .:RING FAC LITY LSE ADJ. WATER AT EL. 12.26 TEST HOLE LOGS ENGINEER: RICK JUDD, RS WITNESS: AMY VON HONE, RS DATE: 5/8/02 PERC. RATE _ - < 2 MIN/INCH CLASS I SOILS P# C� ELEV. EP FILL_] FILL Bw LFS tOYR 5/6 32" 17.7: PERC C FS Bw LFS 10YR 5/6 36" 17.5' C FS 2.5Y 7/2 I LOCV� I 0 I I f o 'so I o` Q� fy G� q Pio R y> it CG�r �s � T LOCATION MAP NOT TO SCALE ASSESSORS MAP 48 PARCEL 39.1 ZONING DISTRICT: R 25 YARD SETBACKS: FRONT = 30' SIDE = 15' REAR = 20' PLAN REF. - FLOOD ZONE: C WELL: MIW 29 ZONE: 'A ADJ: (APRIL) 2.1' 123" OBS. WATER 10.15' 2 �e�oDRVE f-2 4 Ss�124" 124" 10.06' 10.16'.07, 0 1 'LOT 306 20.0 NOTES: 9483tSF o.a1 W APPROXIMATED FROM QUAD MAP 2 SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) 1. DATUM IS 2 `• ^o 10 CF DESIGN FLOW- 3- EEDr'OOMS 010 GPD) = 330 GPD ? r,all� p _. I: l'I AI_ UfATER IS AVAILABLE PROP USE ��2' USE A 330 GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT ./ 9.97 DRIVE `-> '+e2.t5 `o - oP° ti / SEPTIC TANK: 330 PD (�) = 660 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-20 23 �, / 'o �� USE A 1500_ GALLGN SEPTIC TANK 5. PIPE JOINTS TO BE MADE WATERTIGHT. -v, PROP. EXIS-"ING SPOT ELEVATION LEACHING: 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. 100 PROP. FLOOR No IN THE TOWN OF: ENVIRONMENTAL CODE TITLE V. 21,23 DWELL: ELEVATIONAEVE LOWER THANN T 16.5') - ��s SIDES: - 2 37.25 10.83) .58 (.74) = 41.2 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE 2 37.25 x 10,83 (.74) I USED FOR LOT LINE STAKING. 21.30 2�i = z3.o' ^o BOTTOM: = 298.5 8_ PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. �'TF DATE MA SCALE: 1' = 20 DATE: MAY 13, 2002 APPROVED TOTAL: 459 S. F. 339.7 GPD 9. COMPONENTS NOT TO QBE BACKFILLED OR CONCEALED WITHOUT SHED .9, +20,25 USE 5 H-20 STANDARD INFILTRATORS WITH 4' STONE AT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED 02-066 LOT 307 FROM BOARD OF HEALTH, I off 506-362-4541 fox 508 362-9880 I down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main St. yarmouth, ma 02675 P.L.S. DATE =LEGEND TITLE 5 SITE PLAN 100A PROPOSED SPOT ELEVATION ��°s #53 CIRCUIT ROAD NORTH 100x0 EXIS-"ING SPOT ELEVATION 100 IN THE TOWN OF: PROPOSED CONTOUR (WEST) YARMOUTH 100- EXIS'i"ING CONTOUR PREPARED FOR: MICHAEL ARONNE I 20 0 120 40 60 Feet BOARD OF HEALTH DATE MA SCALE: 1' = 20 DATE: MAY 13, 2002 APPROVED off 506-362-4541 fox 508 362-9880 I down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main St. yarmouth, ma 02675 P.L.S. DATE