Loading...
HomeMy WebLinkAbout27 Commercial Street - Grading & Utilities Site Plan3' PEAS ONE OVER PIPE SYSTEM PROFILE 3" MINI PEASTONE 000 75"-i.5" DOUBLE EXISTING SEPTIC SYSTEMS. AND MIRAFI 140N5 0°00° o00o WASHED STONE FABRIC OVER STONE ° TOP FNDN. AT EL. .711' (NOT TO SCALE) °°°0000 °°° ACCESS COVER TO WITHIN 6" OF FIN. GRADE &DOWN SIDES OF TRENCH 3 0000 0 °° °0 ACCESS COVER TO WITHIN 3" OF FIN. GRADE°° °° °° THE TWO EXISTING BUILDINGS WILL HAVE NO CHANGE OF °°° Zp"(o ACCESS COVER (WATERTIGHT) TO ° °°00 °° °° M. ° ° USE. THE EXISTING SEPTIC SYSTEMS WILL REMAIN. tf.g / - °oo°°° WITHIN 6" OF FIN. GRADE H-20 RATED F&C 2$,Q' MINIMUM .75' OF COVER OVER PRECAST 2R SLOPE REQUIRED OVER SYSTEM 2o•y I 3' LeBARON L8268-3 H-20 OR EQUAL MANHOLE FRAME AND COVERS 2" DOUBLE WASHED PEASTONE LABELED "DRAIN" SYSTEM DESIGN. ` RUN PIPE LEVEL OR GEOTEXTILE FABRIC TRENCH CROSS SECTION A -A DRILL (2) 1"0 HOLES IN COVER �k�FOR FIRST 2' N15 ��1500 GAL H-20 3 MAX. DUAL COMP. ADJUSTING BLOCKS/H-20 RISER GARBAGE DISPOSER IS NOT ALLOWED SEPTIC TANK Maly, MORTAR ALL COMPONENTS �ha`i-10 C1'9 (n P.) 4' LIQ. LEVEL (ACME OR EQUAL) GAS 500 GAL BAFFLE ;1(o fo" 16 $Z D O D O O O O D O DESIGN FLOW: WAREHOUSE - NO CAFETERIA 1000 GAL �$ MIRAFl t4oN , c :16 y O 0 0 0 O Q O 0 c 3' PEASTONE OVER PIPE FABRIC OVER TOP STRUCTURES 2' ABOVE INVERTS LISTED , 15 GPD/PERSON X 29 PEOPLE= 435 GPD A (TYP.) ANo OowN sloes _k5% SLOPE) �6" CRUSHED STONE OR MECHANICAL s�� O O O O o o a a o USE A 440 GPD DESIGN FLOWCOMPACTION. (15.221 [21) 0088 2' D O O O ED O O O 14•`i' 4' ------------- =% DEPTH OF FLOW a ( 1 g, SLOPE) (� z SLOPE) SEPTIC TANK: 440 GPD (2) = 880 GAL. 3/4" TO 1 1/2" DOUBLE WASHED STONE ° °° ° ° °° °° °°°°°°°° °°°°°°° TEE SIZES: °oo°° °o° ° ° ° ° °°°°°° °°°° 6'-8 X 60 °0. 000000�o°o °i;°o°o°o� ao 3" MIN. PEASTONE INLET DEPTH = �- 0 0°0°0°0°0° H-20 I USE A 1500 GAL. DUAL COMPARTMENT SEPTIC TANK °°°°°° AND MIVAFI TONE ° A 0000000 0 1000 GAL. fO FABRIC OVER STONE n OUTLET DEPTH 14 12"0 SLOTTED H-20 �a�o�000� LE/CHPIT &DOWN SIDES OF PITS LEACHING: LEACHING og000°° SHOREY OR EQUAL CORRUGATED HDPE PIPE o °°°0000 '-'%"="'-"% SIDES: 2 (10 00 + 40.00) 2 (.74) = 148 GPD FOUNDATION- lex - SEPTIC TANK 25 D' BOX 12' S�t_ ADS N-12 OR EQUAL °°° FACILITY °° BOTTOM 10 00 x 40 00 (.74) = 296 GPD 0g°o°ea-a °°°°°°°°°°°°°°°o °°°°o o °°°°°°°°o°°°°°o PROPOSED 3/4" - 1 1/2" l 1000 GALLON PRECAST TOTAL: 400 S.F. 444 GPD 1 `�` � � / 3'X3' LEACHING TRENCH DOUBLE WASHED STONE � H-20 CATCH BASIN BOTTOM TH 3 EL. °1.0' BETWEEN STRUCTURES WHERE SHOWN 4' MIN. AROUND PIT 6'0X6'-8" SHOREY SOLID USE (4) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) 1 \ SEE TRENCH CROSS SECTION BASIN H-20 OR EQUAL = WITH 2.59 STONE ALONG SIDES & 3 AT BOTH ENDS. 1 tik \ A ELEV. ELEV. ELEV. _ �' _ 3 DRAINA MA I p" 1 21.0' p" 21.0' p" 20_0 APPROVED DATE BOARD OF HEALTH �i+a °yam FILL/A A LS FILL LS 1OYR 3/3 9 1OYR 3/3 7" A 11" B LS B LS 1OYR 3/3 LS / / O - 17" 5 Q 8S PROPOSED 1 OYR 5/8 19.6' 14 „ 17'9 10YR 5/8 , LIGHT POLE B 25 / ati S 00 �,, R 9 5� (n'PJ LS NOT TO SCALE C 24" 10YR 5/8 19.0' C TEST HOLE LOGS PERC PERC / e~ BS1EE ENGINEER: DAVID FLAHERTY, R.S., SE2755 \\\ 'off M5 C MS WITNESS: AMY VON HONE, R.S.41 C.H.O. 20 1 / \\ 3�- DATE* NOVEMBER 21, 2007 mU \ X?'OS \\���2 o ` (LP' \ 0.0 28 \ `` EXISTING 9 O 9.9 SAS \ 14 5\\�``\� 10 �O = 1s i1 16 �� 12 7 EXISTING \ 0 A SEPTIC TANK \ 17 EXISTING %' X61 CONIC. PAD � Vii' is p99 METAL BUILDING kq<F $0 1,847 SF a' METAL BUILDING ��� ,L> � -�O 1,892 SF G EXISTING SLAB=20.1 CONC. PAD s ; d \ ELEC. CONDUIT FOR t a \ALARM & LEAK --� DETECTION s � O •00 \ d+ Ad \Lo.. s LEGEND 100.0 PROPOSED SPOT ELEVATION \ 100x0 EXISTING SPOT ELEVATION f s 100 PROPOSED CONTOUR \ \ - 100 - EXISTING CONTOUR 5 BENCH MARK - HYDRANT ON TAG a BOLT #1075 ELEVATION = 22.8 DCE #07-293 / 19 INV.: INTERIOR DRAINAGE `'o ALARM PANELS FOR TIGHT TANK 2' VENT W/ P.T. B"XB" BOLLARD (OR OPTIONAL VENTILATION THROUGH ROOF) PROPOSED 500 GAL. DOUBLE WALLED FLOOR DRAIN TIGHT TANK W/ LEAK DETECTION ACME/FRALO OR APPROVED EQUAL f fps 0 20 0. f h e � .Tso s o / c, • VEN 'O / ry� / O O / (4) 500 GAL. CHAMBER 00 / W/ DOUBLE WASHED / O o 60•/ STONE 3. ON ENDS & 2.59' ALONG SIDES 500 GAL H-20 /x20.75 DUAL COMPARTMENT SEPTIC TANK y� 20.7 600 GAL ' 0.46 SOLID BASIN / 600 GAL PIT /I? W/ 2' STONE 64 boa � 2.5Y 7/4 MS 2.5Y 7/4 < 2 MIN/INCH PERC. RATE _ 2.5Y 7/4 I I 120" 11_0' 132" 10_0' 132" 9.0' CLASS SOILS P# NO GROUNDWATER ENCOUNTERED 30" & 24" C st Iron Covers 7' T 2" Vent boot ALL AROUND Qj r 6.•'� PROPOSED WATER vel' METER PIT DATE DANIEL A. OJALA, P.L.S., P.E. " " inlet boot Note. a I bolted & gasketed covers required for tight tank. rvert in 4.0't below finished grade Conduit boot(s) for (2) 3/4" conduits ISOMETRIC VIEW 30" & 24" Cast Iron Covers _ bolted & gasketed covers required for tight tank. PLAN VIEW 30" & 24" Cast Iron Covers bolted & gasketed covers required for tight ank. Risers as required (not to scale) Plastic risers & cover to within 12" finish grade oil 4. 2'-6" 6" 4, 6„ 4'41 ,. FILTER FABRIC BETWEEN FRAME & GRATE UNTIL SITE STABILIZED rH-20 INISHED GROUND SURFACE /6" LOAM & SEED UNLESS NOTED R & BRICK LEVELING SURROUNDED BY POURED IN PLACE COLLAR RAPPIPE TO BE PLACED IN 6" LIFTS AND COMPACTED TO 95% MODIFIED PROCTOR DENSITY BY 10 TON MIN. VIBRATORY ROLLER.ENGINEER TO INSPECT ALL SITE WORK. CLEAN SAND FILL ONLY. SECTIONAL PLATE OR SOLID BOTTOM NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 20 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. GRADING & UTILITIES SITE PLAN IN SOUTH YARMOUTH, MA AT 27 COMMERCIAL STREET PREPARED FOR Internal Fralo Internal Fralo PLATINUM AUTO SERVICE, 500 gallon tank 500 gallon tank 3' V PROFILE VIEW (ACME PRECAST SYSTEM OR APPROVED EQUAL) PROFILE VIEW CONCRETE MINIMUM STRENGTH: 5,000 p.s.if AT 28 DAYS RTF -FL REINFORCEMENT: ASTM -A=615-68, GRADE 60 "V NOTES: 1. THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN IS 6. COORDINATE DOWNSPOUT LOCATIONS AND CONNECTIONS WITH ARCH. DWGS. APPROXIMATE. PRIOR TO ANY EXCAVATION ON THIS SITE, THE EXCAVATING 7, ALL SEPTIC PIPING 4"0 SCH-40 PVC UNLESS NOTED. CONTRACTOR SHALL MAKE THE REQUIRED 72 HOUR NOTIFICATION TO DIG SAFE (1-888-344-7233) AND ANY OTHER UTILITIES WHICH MAY HAVE CABLE, PIPE OR 8. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT EQUIPMENT IN THE CONSTRUCTION AREA FOR VERIFICATION OF LOCATIONS. INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 2. ALL CONSTRUCTION MATERIALS, COMPONENTS, AND METHODS EMPLOYED ON THIS g, ALL STORMWATER RUNOFF TO BE RETAINED ON SITE. PROJECT WORK SHALL CONFORM TO THE TOWN OF YARMOUTH SUBDIVISION REGS. AND\OR THE MASSACHUSETTS DEPARTMENT OF PUBLIC WORKS STANDARD 10. COORDINATE UTILITY INSTALLATIONS WITH APPROPRIATE VENDORS. SPECIFICATIONS FOR BRIDGES AND HIGHWAYS AS AMENDED TO PRESENT. ALL SEPTIC WORK AND MATERIALS TO CONFORM TO 310 CMR 15.00 TITLE 5. 11. ALL LIGHTING SHALL CONFORM TO ZONING ORDINANCE. AND YARMOUTH HEALTH REGULATIONS. 12. CONTRACTOR TO PROVIDE FILTER FABRIC BETWEEN FRAME &GRATES 3. VERTICAL DATUM IS NGVD ASSUMED FROM QUAD. MUNICIPAL WATER IS AVAILABLE. AND SILT FENCE AROUND PERIMETER OF WORK AREA UNTIL SITE STABILIZED. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHTO-H20 UNLESS NOTED. _ 5. THIS PLAN IS FOR PROPOSED WORK ONLY AND IS NOT TO BE USED FOR PROPERTY INC. DATE: 6-13-08 PERMIT SET - NOT FOR CONSTRUCTION Scale: 1"= 20' 0 10 20 3C 40 50 FEET off 508-362-4541 fox 508 362-9880 down cape en gin e erin g, in c. CIVIL ENGINEERS LAND SURVEYORS 939 Main Street - YARMOUTHPORT, MASS. SHEET 3 OF 3 07-293 PLATINUM.DWG Gopl, 25 1�05� 2� O \ �S \ P'23 EXIS G CONIC. PAD 22 9 >,o EXISTING C SAS 2t 26 EXISTING \ G SEPTIC TANK \ zo 27 \ 28 PLATINUM AUTO SERVICE, ���9• INC. mU \ X?'OS \\���2 o ` (LP' \ 0.0 28 \ `` EXISTING 9 O 9.9 SAS \ 14 5\\�``\� 10 �O = 1s i1 16 �� 12 7 EXISTING \ 0 A SEPTIC TANK \ 17 EXISTING %' X61 CONIC. PAD � Vii' is p99 METAL BUILDING kq<F $0 1,847 SF a' METAL BUILDING ��� ,L> � -�O 1,892 SF G EXISTING SLAB=20.1 CONC. PAD s ; d \ ELEC. CONDUIT FOR t a \ALARM & LEAK --� DETECTION s � O •00 \ d+ Ad \Lo.. s LEGEND 100.0 PROPOSED SPOT ELEVATION \ 100x0 EXISTING SPOT ELEVATION f s 100 PROPOSED CONTOUR \ \ - 100 - EXISTING CONTOUR 5 BENCH MARK - HYDRANT ON TAG a BOLT #1075 ELEVATION = 22.8 DCE #07-293 / 19 INV.: INTERIOR DRAINAGE `'o ALARM PANELS FOR TIGHT TANK 2' VENT W/ P.T. B"XB" BOLLARD (OR OPTIONAL VENTILATION THROUGH ROOF) PROPOSED 500 GAL. DOUBLE WALLED FLOOR DRAIN TIGHT TANK W/ LEAK DETECTION ACME/FRALO OR APPROVED EQUAL f fps 0 20 0. f h e � .Tso s o / c, • VEN 'O / ry� / O O / (4) 500 GAL. CHAMBER 00 / W/ DOUBLE WASHED / O o 60•/ STONE 3. ON ENDS & 2.59' ALONG SIDES 500 GAL H-20 /x20.75 DUAL COMPARTMENT SEPTIC TANK y� 20.7 600 GAL ' 0.46 SOLID BASIN / 600 GAL PIT /I? W/ 2' STONE 64 boa � 2.5Y 7/4 MS 2.5Y 7/4 < 2 MIN/INCH PERC. RATE _ 2.5Y 7/4 I I 120" 11_0' 132" 10_0' 132" 9.0' CLASS SOILS P# NO GROUNDWATER ENCOUNTERED 30" & 24" C st Iron Covers 7' T 2" Vent boot ALL AROUND Qj r 6.•'� PROPOSED WATER vel' METER PIT DATE DANIEL A. OJALA, P.L.S., P.E. " " inlet boot Note. a I bolted & gasketed covers required for tight tank. rvert in 4.0't below finished grade Conduit boot(s) for (2) 3/4" conduits ISOMETRIC VIEW 30" & 24" Cast Iron Covers _ bolted & gasketed covers required for tight tank. PLAN VIEW 30" & 24" Cast Iron Covers bolted & gasketed covers required for tight ank. Risers as required (not to scale) Plastic risers & cover to within 12" finish grade oil 4. 2'-6" 6" 4, 6„ 4'41 ,. FILTER FABRIC BETWEEN FRAME & GRATE UNTIL SITE STABILIZED rH-20 INISHED GROUND SURFACE /6" LOAM & SEED UNLESS NOTED R & BRICK LEVELING SURROUNDED BY POURED IN PLACE COLLAR RAPPIPE TO BE PLACED IN 6" LIFTS AND COMPACTED TO 95% MODIFIED PROCTOR DENSITY BY 10 TON MIN. VIBRATORY ROLLER.ENGINEER TO INSPECT ALL SITE WORK. CLEAN SAND FILL ONLY. SECTIONAL PLATE OR SOLID BOTTOM NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 20 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 12. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. GRADING & UTILITIES SITE PLAN IN SOUTH YARMOUTH, MA AT 27 COMMERCIAL STREET PREPARED FOR Internal Fralo Internal Fralo PLATINUM AUTO SERVICE, 500 gallon tank 500 gallon tank 3' V PROFILE VIEW (ACME PRECAST SYSTEM OR APPROVED EQUAL) PROFILE VIEW CONCRETE MINIMUM STRENGTH: 5,000 p.s.if AT 28 DAYS RTF -FL REINFORCEMENT: ASTM -A=615-68, GRADE 60 "V NOTES: 1. THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN IS 6. COORDINATE DOWNSPOUT LOCATIONS AND CONNECTIONS WITH ARCH. DWGS. APPROXIMATE. PRIOR TO ANY EXCAVATION ON THIS SITE, THE EXCAVATING 7, ALL SEPTIC PIPING 4"0 SCH-40 PVC UNLESS NOTED. CONTRACTOR SHALL MAKE THE REQUIRED 72 HOUR NOTIFICATION TO DIG SAFE (1-888-344-7233) AND ANY OTHER UTILITIES WHICH MAY HAVE CABLE, PIPE OR 8. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT EQUIPMENT IN THE CONSTRUCTION AREA FOR VERIFICATION OF LOCATIONS. INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 2. ALL CONSTRUCTION MATERIALS, COMPONENTS, AND METHODS EMPLOYED ON THIS g, ALL STORMWATER RUNOFF TO BE RETAINED ON SITE. PROJECT WORK SHALL CONFORM TO THE TOWN OF YARMOUTH SUBDIVISION REGS. AND\OR THE MASSACHUSETTS DEPARTMENT OF PUBLIC WORKS STANDARD 10. COORDINATE UTILITY INSTALLATIONS WITH APPROPRIATE VENDORS. SPECIFICATIONS FOR BRIDGES AND HIGHWAYS AS AMENDED TO PRESENT. ALL SEPTIC WORK AND MATERIALS TO CONFORM TO 310 CMR 15.00 TITLE 5. 11. ALL LIGHTING SHALL CONFORM TO ZONING ORDINANCE. AND YARMOUTH HEALTH REGULATIONS. 12. CONTRACTOR TO PROVIDE FILTER FABRIC BETWEEN FRAME &GRATES 3. VERTICAL DATUM IS NGVD ASSUMED FROM QUAD. MUNICIPAL WATER IS AVAILABLE. AND SILT FENCE AROUND PERIMETER OF WORK AREA UNTIL SITE STABILIZED. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHTO-H20 UNLESS NOTED. _ 5. THIS PLAN IS FOR PROPOSED WORK ONLY AND IS NOT TO BE USED FOR PROPERTY INC. DATE: 6-13-08 PERMIT SET - NOT FOR CONSTRUCTION Scale: 1"= 20' 0 10 20 3C 40 50 FEET off 508-362-4541 fox 508 362-9880 down cape en gin e erin g, in c. CIVIL ENGINEERS LAND SURVEYORS 939 Main Street - YARMOUTHPORT, MASS. SHEET 3 OF 3 07-293 PLATINUM.DWG