HomeMy WebLinkAbout95.17 - Septic System DesignACCESS COVERS MUST BE WITHIN 9' MINIMUM, 6- OF FINISH GRADE 3' MAXIMUM COVER MIN 2' OF PEASTONE FIRST JO D314'OUBLE - I I/2' DIA. BE LEVELEL DOUBLE WASHED STONE 95.5 95.7 2' 40 MILL POLY 95.2 VAPOR BARRIER 3 OUTLET 2-500 GAL LEACHING CHAMBERS EXISTING D -80X W/4' STONE AROUND. 12.8'r x 25'1 x 2'd 9I.5 1000 GAL SEPTIC TANK 6- CRUSHED STONE OR COMPACTED BASE PROF I L E: NOT TO SCALE l'�.r SOIL REMOVAL N SEE NOTE 9. �� �- �� 133• 6 /moi ------ 0 ---0 1 02' 94' DR 91.7 1 ( / I,--- \\ D -BOX! _-- 40 MILL POLY VAPOR BARRIER 2-500 GALLON LEACHING CHAMBERS I � / [ JI'/4' STONE AROUND/ i ^ +97. J BM -LEFT CORNER OF } \ •\ �'\ \ \ \ \ TPrI DOOR JAM. EL -98.0 /95 ' \ �\ PA G BEDROOM BEDROOM %• 7 SEX/STI NGS .\�� BATH m \ / I XI LIVING EXISTING 1000 G\\,, CHEN RAN \\ \\ \\ SEPTIC TANK KIT p 7,/ ! !\\ 99.5 /\\ _ G BEDROOM M Q r _ PRO 5ED PAVED DRIVE 1 _ADBitTION GARAGE \ \ r_ \ // 44 PROpp§ED p. {1ij, V I PAT. ISG,>.' U L o T r r ! 20.082' S. F. � AP //,-u WEPT• ���-�'�/ LOCUS MAP 0 10 20 40 INVERT ELEVATIONS. In CB INVERT UUT SEPTIC TANK: 95.7 INVERT IN DIST. BOX., 95.2 INVERT OUT DIST. BOX: 95.03 INVERT IN LEACH CHAMBER: 95.0 BOTTOM OF LEACH CHAMBER: 93.0 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE •1: 88.0 N y to v \ LEGEND DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT //0 O.P.D. PER BEDROOM EOUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200x - 660 GAL. SEPTIC TANK PROVIDED: 1000 GAL. EXISTING SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE C 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REOUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-471 S.F. 471 S.F. x 0.74 - 348 G.P.D. SOIL TEST PIT DA TA S INDICATES INDICATES PERCOLATION OBSERVED TEST GROUNDWATER TP +1 HORIZON TEXTURE In CB CONCRETE BOUND -W- WATER LINE /2 - ................... .................... O HYDRANT B LOAMY IOYR -G- GAS LINE 7 / O - OHW- OVER HEAD WIRES .i YJ LIGHT POST -E- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE 6/6 - CTV- UNDERGROUND CABLEVISION LINE ORA VEL + 40.4 SPOT ELEVATION X140-, EXISTING CONTOUR 401 PROPOSED CONTOUR DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT //0 O.P.D. PER BEDROOM EOUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200x - 660 GAL. SEPTIC TANK PROVIDED: 1000 GAL. EXISTING SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE C 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REOUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-471 S.F. 471 S.F. x 0.74 - 348 G.P.D. SOIL TEST PIT DA TA S INDICATES INDICATES PERCOLATION OBSERVED TEST GROUNDWATER TP +1 HORIZON TEXTURE COLOR 97.0 0, FILL /2 - ................... .................... 96.0 B LOAMY IOYR SAND 5/8 22 .............. ............ 95.2 C I COARSE IOYR SAND AND 6/6 ORA VEL 48- 108' 1 NO WATER L 88.0 DATE: MARCH 8. 2006 TEST BY: STEPHEN HAAS WITNESSED BY: PHIL RENAUD PERC RATE' C 2 A41 INCH GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING PURPOSES ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EOUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL -DIG -SAFE.. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING LEACH PIT TO BE PUMPED DRY AND BACKFILLED. IL 1 SEP T / C S YS TEM DES / G/V /7 COT7-0^1W000 STREET. MAP 95. PARCEL /7 YAA?"OUTHP0R T. "A . PREPARED FOR : BILL deMART/N SOAL E : / - 20 APRIL .2-5. 2005 REVISED: NOVEMBER 3. 2006 EACL_E SUFRVEY I NG I NC 923 Route 6A Yormouthport MA. 02675 ( 508 ) 362-8132 ( 508 ) 432-5333